Spillover Kit Installation Instructions 

 

8:1 

Mounting 

The Frigoboat Spillover Kit (with integral mechanical thermostat) should be installed on the barrier 
dividing the freezer and refrigerator sections, on the refrigerator side, and no lower than at mid-height. 
Screws may be used after drilling holes in the plastic flange. 
 
A 2.25” diameter hole needs to be cut through the barrier to allow air to flow to the fan; a piece of 
PVC pipe can be used to line the hole if desired. This will also make a neat finish while sealing the 
hole from the ingress of moisture. The hole may be directly behind the evaporator in the freezer 
section, and this will not be detrimental to performance. If a stand-alone Spillover Fan is used (this 
requires a Coastal MKII thermostat), the Spillover Fan may be surface-mounted or installed within the 
thickness of the barrier. 
 
A return air path must be established at the top of the barrier to allow air back into the freezer. This can 
either be in the form of a gap at the top of the barrier (1” should be sufficient) or 3 or more holes of the 
same size as the one behind the spillover fan. All other holes, gaps, etc, in the barrier must be 
completely sealed, including drains. 
 

8:2 

Electrical Connections 

The Spillover Kit (with integral mechanical thermostat) must be powered by an

 independent

 12v 

supply. This may be from a breaker on the electrical panel or via an in-line 2-amp fuse from the same 
supply that is feeding the refrigeration system. Do not power the Spillover Kit from the fan terminals 
on the controller. If using the stand-alone Spillover Fan (this requires a Coastal MK II digital 
thermostat), refer to wiring diagrams included with these products. 
 

8:3 

Operation 

The temperature dial of the Spillover Kit must be set to the desired temperature in the refrigerator 
compartment. This may take some trial and error before the ideal temperature is achieved. A period of 
at least one day is suggested between changes in settings. The temperature dial is in degrees Celsius 
and the setting is read against an indent in the plastic housing at the six o-clock position, above the 
Frigoboat sticker. A setting of +5 is suggested initially and then adjusted accordingly as desired. 

  

Содержание Frigoboat Capri 35F

Страница 1: ...s Air Cooled Pumped Water Cooled Keel Cooled and Keel plus Air Cooled Systems using Secop formally Danfoss BD 35 or BD 50 compressors It is important to read this manual thoroughly before installing a...

Страница 2: ...it or an Air Add On air cooled condenser is installed together with a Keel Cooler ensure that the fan is operated only when the boat is out of the water and then switched off when the boat is launched...

Страница 3: ...Capri 35F Capri 50F Air cooled These units are designed to be mounted with compressor right way up on a horizontal surface in areas where they will not be susceptible to physical or water damage but...

Страница 4: ...ll deliver 12v even if the system is connected to a 24v supply Full wiring instructions are included with the compressor If more than one W35 or W50 is sharing a single water pump they must be plumbed...

Страница 5: ...ion of the transom that is below the waterline when at rest Keep the two tubes from the Keel Cooler separate from each other and do not insulate them It is extremely important to orientate the cylindr...

Страница 6: ...control running at 2000 RPM All others must have either a manually adjustable compressor speed controller like a Speed Board or alternatively an automatic smart speed control such as the Merlin II Sma...

Страница 7: ...to the controller there may be a delay of up to 30 seconds before the compressor starts Note 2 If initial power is applied that is above the low voltage threshold but below the cut in voltage value se...

Страница 8: ...els in the evaporator Never attempt to bend a plate downwards over a pipe as damage may result The area to be bent should be warmed with a hair dryer or heat gun to approximately 200 F before bending...

Страница 9: ...lastic plate on the evaporator so that it lays in the special grooves of the plastic plate Finish by tightening the clamping screw If using the Coastal MK3 digital thermostat the sensor mounts on the...

Страница 10: ...refully coiled up and secured out of the way to avoid damage When securing the sensing tube make sure contact is made only with the evaporator at the point where it is attached under the plastic mount...

Страница 11: ...top of the barrier 1 should be sufficient or 3 or more holes of the same size as the one behind the spillover fan All other holes gaps etc in the barrier must be completely sealed including drains 8...

Страница 12: ...talled until the very last moment when you are ready to connect the system together Once the dust caps have been removed it is imperative that the exposed components and surfaces be kept free of dust...

Страница 13: ...tion Use either a breaker or fast blow fuse with 15 amp rating for a 12v supply or 7 5 amp for 24v 10 4 Connections Power Connect the power supply to the controller on the top two terminals using slip...

Страница 14: ...factory installed on the terminals marked F Black or Blue and Red If the wires are reversed the fan will not run The K50F and W50F models have a small oil cooler fan installed Full instructions are i...

Страница 15: ...oller or compressor to be faulty Controller can be removed by unscrewing the retaining screw or by levering the plastic case over the screw head 11 1 Compressor not running no start attempt Probable c...

Страница 16: ...ty or inadequate power supply Most likely Monitor the supply voltage at the power terminals on the controller before during and after start attempts to ensure that it does not fall below threshold lev...

Страница 17: ...ng in others the system may be low on refrigerant or overcharged Call Veco NA for advice or go to www veco na com Technical Information 7 Drain left unplugged If your icebox is equipped with a drain i...

Страница 18: ...lation 11 5 Excessive frost build up Note This is the result of moist air being allowed to enter the box Problems are compounded when cold dense air leaks from the lower area of the box through an ope...

Страница 19: ...cation Acts of God or service by personnel other than those pre authorized by the Company Damage failure or malfunction resulting from inadequate or faulty power supply to the system or improper fault...

Отзывы: