9.
Serial IMU
channels (
x accel, y accel, z accel, temp, pitch rate, roll rate and yaw rate
) will also automatically
be set to log. If Serial IMU data is required to be displayed as a Live Serial
data display
then the user must tick
the channels for '
Send over serial
'.
10. Select '
Write to unit
' to upload settings to VB3i.
11. Perform
initialisation and full calibration
procedure before commencing testing.
VBOX Manager
1. Ensure IMU04 is connected via RLCAB119, and the VBOX 3i is powered on.
2. Connect
to the VBOX.
3. Enter the '
SETUP
' menu of VBOX Manager.
4. Select '
IMU-INS
' and then click on the '
IMU Integration
' menu.
5. Scroll to '
Enable
' and select. Once the '
OK
' confirmation screen has cleared, '
Enabled
' will be displayed.
https://en.racelogic.support//Product_Info/VBOX_Data_Loggers/VBOX_3i_Range/VBOX_3i_User_Guide_(All_Variants)/12-2_-
_VB3i_IMU_Integration_-_Roof_Mounted
82