6
Supply to the heater only the voltage stamped on the rating
plate.
Mark the electrical shut off clearly for future emergency use.
Read wiring diagrams before making electrical connections
(See WIRING DIAGRAM 1)
Field connections with aluminum conductors must use
connectors approved for copper to aluminum connection.
CAUTION: There is a risk of electric shock in an
ungrounded service. It is critical that this unit be wired
with a power supply that has a service ground wire
available. Be sure to connect the ground wire to the
green ground screw in the junction box.
H. SUPPLEMENTAL HEAT WARNINGS
NOTE: Heat input from any external or additional source will
void the warranty.
When a supplemental heat source is connected to the
Certified Household Electric Storage Tank Water Heater,
provision must be made to limit the heat source temperature
not to exceed that of the water heater thermostat setting.
Caution: If the water heater has been retrofitted with
supplemental heating equipment, you must adjust both
the thermostat controlling the supplemental heat source
(located in the water piping) and the temperature
controller on the water heater to the same temperature.
Failure to adjust both temperature controllers to the
same setting can cause loss of proper temperature
control.
I.
INSULATION INSTALLATION
Place included fiberglass insulation between and around the
water supply and element wires. Attach lid using snap rivets
provided. Insulate hot water pipes with pipe insulation.