background image

 

3

. Installing the Equipment 

EzRay Air W (Model: VEX-S300W) Installation Manual 

33 

EN

G

LISH

 

6.  Cover three holes with caps (Part No. 9, 10). 

GENERATOR ARM 

COVER CAP1 

Part No.: 9 
Qty.: 1 ea 

 

GENERATOR ARM 

COVER CAP2 

Part No.: 10 
Qty.: 1 ea 

 

GENERATOR ARM 

COVER CAP3 

Part No.: 11 
Qty.: 1 ea 

 

 

 

Содержание EzRay Air W

Страница 1: ......

Страница 2: ......

Страница 3: ......

Страница 4: ......

Страница 5: ...of this manual is recommended before installation to ensure proper installation of this equipment The EzRay Air W is in steady improvement The information contained in this manual may be subject to ch...

Страница 6: ...ymbols indicate a compulsory action or instruction Notes help you optimize system performance Carefully read each note to ensure that the equipment is used to its full potential Radiation symbols indi...

Страница 7: ...50 for more than a couple of hours allow the equipment to reach room temperature before applying mains voltage Installation and related work must only be performed by people authorized by VATECH Do no...

Страница 8: ...of other devices Do not install the equipment in an area that is exposed to strong electromagnetic fields Do not install this system in an area where there is the risk of an explosion The electrical i...

Страница 9: ...cking the Components 7 3 Installing the Equipment 15 3 1 Marking Drill points on the wall 18 3 2 Installing the Power Box Assembly 18 3 3 Installing the Horizontal Arm 27 3 4 Installing the Scissor Ar...

Страница 10: ...Table of Contents x EzRay Air W VEX S300W Installation Manual This page intentionally left blank...

Страница 11: ...qualified technician s from one of our authorized agents The equipment has been used under normal condition in accordance with the user s manual 1 2 Customer s Responsibility Site planning and prepara...

Страница 12: ...1 Introduction 2 EzRay Air W Model VEX S300W Installation Manual This page intentionally left blank...

Страница 13: ...re required to install the equipment safely 2 1 Required Tools The following tools are necessary to install the equipment Item Figure Size Wrench set 1 5 mm 10 mm 0 05 0 4 Monkey wrench 10 Ratchet wre...

Страница 14: ...2 Before Installing the Equipment 4 EzRay Air W Model VEX S300W Installation Manual Item Figure Size Marker pen thick tip Hammer Multi meter Hammer drill Cutting pliers...

Страница 15: ...ackaging for signs of damage visually before opening the package If it appears damaged do not open the package and immediately contact the shipping company agent or VATECH Wear the ant static or gener...

Страница 16: ...X S300W Installation Manual Unpacking the Main Box 1 Move the main box to a convenient place as close as possible to the installation location 2 Remove each box in the following order A Top Cover B Up...

Страница 17: ...W Model VEX S300W Installation Manual 7 ENGLISH 2 3 Checking the Components Upper Box B No Items Figure QTY Comments Confirmed 1 Double Stud 1 YES NO 2 Installation manual 1 YES NO 3 Anchor Bolt 5 YE...

Страница 18: ...rizontal Arm Box C and Lower Box D No Items Figure Qty Comments Confirmed 5 Horizontal Arm 1 3 options 450mm 600mm 900mm YES NO 6 Scissor arm 1 Cable included YES NO 7 Power Box Assembly 1 YES NO 8 X...

Страница 19: ...0 Double Stud Cover 2 YES NO 11 Remote Exposure Switch Assembly Remote Exposure Switch Holder included YES NO 12 X ray Generator Arm Bushing 1 YES NO 13 X ray Generator Stopper 1 YES NO 14 Remote Expo...

Страница 20: ...ixing Washer for X ray Generator Stopper 1 YES NO Fixing Screw for X ray Generator Stopper 1 YES NO 20 AC Power Cable 1 YES NO Door Interlock Cable 1 YES NO 21 Silicone Cap 1 gray 2 YES NO Power Box S...

Страница 21: ...Horizontal Arm Cable Cover ABS White 1 YES NO 3 Power Box Cover Deco ABS White 1 YES NO 4 Silicone Cap 1 white Silicone 2 YES NO 5 Power Box Screw PH M4 x 6 4 YES NO 6 X ray Generator Arm Bushing AL...

Страница 22: ...DIN571 M10 3 YES NO 14 Fixing Washer for X ray Generator Stopper Washer SP M3 1 YES NO 15 Fixing Screw for X ray Generator Stopper PH M3 x 5 1 YES NO 16 ANTI ROTATION BLOCK 2 ACETAL Black 1 YES NO 17...

Страница 23: ...art No Items Specification Figure Qty Confirmed 23 Drilling Template Paper Size A3 1 YES NO 24 Cable Tie 3 YES NO 25 Rectangular Cover 2x3 ABS FOV 2x3 3x2 1 YES NO 26 Rectangular Cover 4x3 ABS FOV 4x3...

Страница 24: ...Manual Part No Items Specification Figure Qty Confirmed 30 Double Stud Cover ABS White 2 YES NO 31 Double Stud Cover Screw FH M4 x 8 8 YES NO 32 Remote Exposure Switch Doorbell type 1 YES NO 33 Remote...

Страница 25: ...mounting supports must be used to fulfill this requirement You are advised to plan and study the installation environment carefully in advance before proceeding since the installation involves drillin...

Страница 26: ...nting type Mounting points on the wall Cabinet Installation Wood wall Wood screw X 6 Part No 13 Concrete wall Anchor X 6 Part No 19 Anchor wrench bolt X 6 Part No 18 Wall Bracket Installation Single S...

Страница 27: ...odel VEX S300W Installation Manual 17 ENGLISH Mounting type Mounting points on the wall Wall Bracket Installation Double Stud Optional Wood wall Wood screw X 6 Part No 13 Concrete wall Anchor X 6 Part...

Страница 28: ...be placed on the middle 3 If it is tape the drilling template temporally at three or four corners 4 Mark the holes on the wall according to the mounting type and then remove the drilling template 3 2...

Страница 29: ...Installation Manual 19 ENGLISH 1 Remove the front cover of the Power Box Assembly 2 Attach the Power Box Base to the wall with six wood screws M10 RATCHET WRENCH HEX HEAD WOOD SCREW Part No 13 Size B...

Страница 30: ...ion 2 Attach the Power Box Base to the wall with three wood screws RATCHET WRENCH HEX HEAD WOOD SCREW Part No 13 Size BN M10 Qty 3 ea Wall Mount Type Double Stud Optional 1 Perform the step 1 in the C...

Страница 31: ...W Model VEX S300W Installation Manual 21 ENGLISH 3 Assemble the Double Stud Covers with eight flat head screws M4 x 8 Double Stud Cover Screw Part No TBD Size M4 x 8 Qty 8 ea 4 Attach two double stud...

Страница 32: ...zRay Air W Model VEX S300W Installation Manual 5 Attach the Power Box Base to the Double Stud Frame with six wrench bolts w spring and flat washer Allen wrench 7 Wrench bolt Part No 18 w spring and fl...

Страница 33: ...Assembly For Concrete walls 1 Drill the marked points using the hammer drill 2 Remove the debris and clean the holes using the dust pump 3 Anchor the bolts Part No 19 with the hammer Hammer Anchor bol...

Страница 34: ...Installation Manual 5 Attach the Power Box Base to the anchors with six anchor wrench bolts DO NOT tighten the bolts completely until after leveling is completed Allen wrench 7 Anchor wrench bolts Par...

Страница 35: ...level on the position as shown in the figure 2 To adjust the horizontality level loosen one wrench bolt by using the wrench 3 Adjust the headless wrench bolt until the bubble on the spirit level is pl...

Страница 36: ...n Manual 3 2 4 Leveling the Power Box Assembly Left Right 1 Place the spirit level on the position as shown in the figure 2 After placing the spirit level on its position adjust the 2 bolts until the...

Страница 37: ...are the same regardless of the arm s length 1 After pulling out the cables through the opening insert the horizontal arm into the hole on the Power Box Assembly 2 Fix the block assembly using the ant...

Страница 38: ...lts 3 3 1 Leveling the Horizontal Arm 1 Place the spirit level on the position as shown in the following figures Front Rear Left Right 2 Check if the bubble on the spirit level is placed in the middle...

Страница 39: ...emove the safety strap and shrink wrap for scissor arm until the installation is completed When you remove the strap and shrink wrap the scissor arm will be opened by its spring tension This can cause...

Страница 40: ...ten the wrench bolt in the the Horizontal Arm Frame End and cover the Frame End with the Horizontal Arm Frame Cover Part No 1 Horizontal Arm Frame Cover Part No 1 Qty 2 ea Front Rear Location of the h...

Страница 41: ...ead 1 Attach the the X ray Generator Assembly to the scissor arm while making sure that the cables from the Scissor Arm go through the X Ray Generator Arm s hole 2 For information about connecting cab...

Страница 42: ...he Equipment 32 EzRay Air W Model VEX S300W Installation Manual 4 Cover the rear side of the X ray Generator Arm with the X ray Generator Arm Cover 5 Tighten three bolts on the rear cover of the X ray...

Страница 43: ...y Air W Model VEX S300W Installation Manual 33 ENGLISH 6 Cover three holes with caps Part No 9 10 GENERATOR ARM COVER CAP1 Part No 9 Qty 1 ea GENERATOR ARM COVER CAP2 Part No 10 Qty 1 ea GENERATOR ARM...

Страница 44: ...NOT wear a thick jacket Always ensure that the cables are connected firmly Bad connection could cause deterioration of image quality 3 6 1 Connecting the Power Cord 1 Connect the N Neutral and L Live...

Страница 45: ...0 mm 2 The installation procedures are the same regardless of the horizontal arm length 1 Connect the cable H001624 with the Connector 1 2 on the Power Box Board and the Protective Earth PE Cable on t...

Страница 46: ...del VEX S300W Installation Manual 3 6 3 Cabling between the Scissor arm and horizontal arm Horizontal Arm Scissor Arm During cable installation avoid any cable kinks and maintain the proper bending En...

Страница 47: ...horizontal arm and scissor arm 1 White connector 3 pin White connector 3 pin 2 Black connector 8 pin Black connector 8 pin 3 Protective Earth PE Cable from the Scissor Arm When you connect the Protec...

Страница 48: ...m opening with the HORIZONTAL LOWER COVER Part No 2 HORIZONTAL ARM CABLE COVER Material ABS White Part No 2 Qty 1 ea 3 6 4 Cabling between the Scissor Arm and the X ray Generator 1 White connector 3 p...

Страница 49: ...3 Installing the Equipment EzRay Air W Model VEX S300W Installation Manual 39 ENGLISH 3 6 5 View After Completion...

Страница 50: ...r Cable Connector The standard and optional Remote Exposure Switches and the Door Interlock Cable are connected to the Connector 1 2 and 3 Please check all seven possible options in the table below Op...

Страница 51: ...emote Exposure Switch Standard 2 Remote Exposure Switch Doorbell type Option Option 4 Press 1 N A AC Power Cable Option 1 Remote Exposure Switch Standard 2 Door Interlock Cable Option Option 5 Press 1...

Страница 52: ...ion No Description Connector 1 Connector 2 Connector 3 Connector 4 Option 7 Press 2 and 3 at the same time 1 Not used in this option AC Power Cable Option 1 Remote Exposure Switch Standard 3 Remote Ex...

Страница 53: ...4 Product Specifications EzRay Air W Model VEX S300W Installation Manual 43 ENGLISH 4 Product Specifications 4 1 Mechanical Specifications Dimensions...

Страница 54: ...4 Product Specifications 44 EzRay Air W Model VEX S300W Installation Manual...

Страница 55: ...Scissor Arm 892 6mm 14 15 With unfolded Scissor Arm maximum 2005 5mm Power Box Assembly 287 8 W x 238 0 L 1 6 Total Arm Assembly 900 mm With folded Scissor Arm 1069 3 W x 879 0 L x 54 4 H 11 45 With u...

Страница 56: ...eight kg Horizontal Arm Assembly 900mm 979 0 W x 54 4 L x 58 2 H 3 65 X ray Generator Assembly 325 0 W x 298 9 L x 215 3 H 2 4 X ray Beam Limiting Device X ray Beam Area mm Round Type FOV 60 0 013 Rec...

Страница 57: ...tection Thermistor 60 C Inherent Filtration 1 8 mm Al 65 kV Total Filtration Min 1 5 mm Al Type Inverter Type Tube Voltage 55 65 kV Tube Current 1 0 3 0 mA X ray Tube Manufacturer VATECH Co Ltd Model...

Страница 58: ...wer Rating Max 350 VA Tube Voltage 65 kV fixed 3 Tube Current Option A 2 5 mA Option B 3 0 mA Accuracy Error kVp 10 mA 20 s 5 or 20 ms The input line voltage depends on the local electrical distributi...

Страница 59: ...al 49 ENGLISH 4 4 Environmental Specifications Item Description During operating Temperature 10 35 Relative humidity 30 75 Atmospheric pressure 860 1060 hPa Transport and storage Temperature 10 60 Rel...

Страница 60: ...4 Product Specifications 50 EzRay Air W Model VEX S300W Installation Manual This page intentionally left blank...

Страница 61: ...Appendix EzRay Air W Model VEX S300W Installation Manual 51 ENGLISH Appendix Drilling Template...

Страница 62: ...ion about the equipment purchaser Customer Name of Clinic or Hospital Address Phone E Mail Information about the equipment seller Dealer Name of dealer Phone E Mail Web site 2 Installation information...

Страница 63: ...nual Did installer make sure harness and equipment are well connected and not damaged Did the equipment be well balanced 4 After installation After installation Checklist Yes No Is it OK after checkin...

Страница 64: ...Appendix 54 EzRay Air W Model VEX S300W Installation Manual This page intentionally left blank...

Страница 65: ...representative Manufactured by VATECH Co Ltd Tel 82 1588 9510 Email gcs vatech co kr Website www vatech co kr Head Quarters Address 13 Samsung 1 ro 2 gil Hwaseong si Gyeonggi do 18449 Korea Factory A...

Страница 66: ......

Страница 67: ......

Страница 68: ......

Отзывы: