![VAT 616 Series Скачать руководство пользователя страница 6](http://html1.mh-extra.com/html/vat/616-series/616-series_installation-operating-and-maintenance-instructions_4088275006.webp)
DESCRIPTION OF PRODUCT
Series 616
6/56
Edition 2020-01-22
893179ED.DOCX
1.6
Technical data
1.6.1
Control and actuating unit
Description
Power supply input
1)
+24 VDC (±10%) @ 0.5 V pk-pk max.
Power consumption
40 W max.
Ambient
temperature
0 °C to +50 °C max. (<35 °C recommended)
humidity
0 to 95% RH, non-condensing
Interface
remote
Logic
local
service port USB-B
Analog input / output
position control
0…10V; Resolution 2.5 mV
Digital inputs:
2)
- Input 1
- Input 2
open valve
close valve
adjustable with CPA 4.0
adjustable with CPA 4.0
Digital outputs:
2)
- Output 1
- Output 2
valve closed
valve open
adjustable with CPA 4.0
adjustable with CPA 4.0
Position resolution
4000 (full stroke)
Actuator backlash
< 0.1°
Closing / Opening time
throttling only
380 ms
throttling & isolation
390 ms
Protective system
IP 40
Utilizable valve torque
2.5 Nm
1)
Internal overcurrent protection by a PTC device.
2)