Series 140
MAINTENANCE
875067EA
Edition 14.07.2020
35/43
4. Carefully position rotary drive (2) centered on the mounting flange.
5. Install screws and spring-lock washers (3). Tighten screws in crosswise order.
Figure 7-14
6
Dowel pin
7
Gate lever
6. Position gate lever (7) on the square shaft of the rotary feed through. Check and make
sure that the drill holes on the gate lever and on the square shaft are matching up.
7. Insert the dowel pin (6).
8. Install valve gate. See chapter «7.5 Installing valve gate».
9. Install position indicator. See chapter «7.7 Installing position indicator».
10. Connect compressed air supply.
11. Connect electrical power supply.
The valve is ready to use.
7
6