Proceed as follows to adjust the intermediate position:
For easy adjustment, VAT recommends to switch off the compressed air
supply while adjusting the intermediate position.
1. Loosen locking screw (2) using a 2.5 mm Allen wrench.
2. To adjust intermediate position, rotate bolt screw (3) using an 8 mm Allen wrench.
•
Rotating the bolt screw clockwise moves the intermediate position
towards the “open” position.
•
Rotating the bolt screw counter-clockwise moves the intermediate
position towards the “closed” position.
3. Tighten locking screw (2) after intermediate position is adjusted.
Figure 5-2
1
Micro switch adjustment screw
2
Micro switch intermediate position
4. Rotate micro switch adjustment screw (1) until the signal contact of the micro switch for
the intermediate position (2) is closed (refer to electrical diagram).
1
2