Series 140
MAINTENANCE
875067EA
Edition 14.07.2020
31/43
7.7
Installing position indicator
Proceed as follows to install the position indicator:
1. Check and make sure valve is closed and locked.
Figure 7-10
1
Slotted screws
2
Position indicator
3
Flat wrench
2. If valve is not closed, use a flat wrench (3) with appropriate size and rotate the square
shaft of the rotary feedthrough counter-clockwise until the valve is closed and locked.
3. Position the position indicator (2) over the square shaft. Do not tilt.
4. Install four slotted screws (1) using a slotted screwdriver.
5. Connect compressed air supply.
6. Connect electrical power supply.
The valve is ready to use.
1
2
3