06 INSTALLATION
2 INSTALLATION
POSITIONING THE UNIT
Avoid installing the unit in proximity to:
- positions subject to exposure to direct sunlight;
- in proximity to sources of heat;
- in damp areas or places with probable contact with water;
- in places with oil fumes
- places subject to high frequencies.
Make sure that:
- the wall on which the unit is to be installed is strong enough to support the
weight;
- the part of the wall interested does not have pipes or electric wires passing
through;
- the interested wall is perfectly flat;
- there is an area free of obstacles which could interfere with the inlet and
outlet air flow;
- the installation wall is preferably an outside perimeter wall to allow the
discharge of the condensation outside;
The following descriptions of the various mounting phase and the relative
designs refer to a version of the machine with fixtures on the left.
To ensure that the installation is performed correctly and that the appliance will
perform perfectly carefully follow the instructions indicated in this manual. Failure
to respect the rules indicated not only can cause malfunctions of the appliance
but will also invalidate the warranty and hence VASCO shall not respond for any
damage to persons, animals or property.
Figure indicates the minimum mounting distances between the wall-mounted
cooler-convector and furniture present in the room.
INSTALLATION MODES
MINIMUM
INSTALLATION
DISTANCES
Содержание NIVA FC115
Страница 13: ...12 LOCKSHIELD ADJUSTMENT load losses based on the adjustment of the lockshield present in all kits...
Страница 14: ...3 WAY VALVE diagram of load losses of 3 way valve in completely open position 3 WAY VALVE 13 NL FR DE EN IT PL...
Страница 15: ...diagram of load losses of 3 way valve in completely closed position 14 LOCKSHIELD ADJUSTMENT...
Страница 19: ...Kruishoefstraat 50 B 3650 Dilsen T 32 0 89 79 04 11 F 32 0 89 79 05 00 info vasco eu www vasco eu 90 DR013038 D...