F3:
Adjusts the values on the ramping curve. The
LED display shows NN:VVV. NN represents the
point’s number whereas VVV represents point N’s
corresponding temperature value. When Growth
Day is OFF, VVV flashes and can be adjusted
with the + and - buttons. Press F3 to switch
points.
The following graph shows a typical ramping curve for
the main set point.
This five point curve may be entered as follows:
1 Make sure the Growth Day setting is OFF (see section
3.2.2).
2 Select the Main Set Point parameter with the arrow
buttons.
3 By now, the LCD should read "Main Set Point”. The
value on the LED display should be flashing. If not, it is
because the GrowthDay parameter is still ON.
Figure 10 Typical Ramping Curve