background image

TECHNICAL INFORMATION

7

87-900-939-01 (D)

Serial Communication Windows

WIN

TYPE

R W

Description

000

L

X

X

START/STOP (1= START ; 0= STOP)

008

L

X

X

REMOTE/SERIAL Configuration (1= Remote ; 0= Serial)

100

L

X

X

SOFT START YES/NO (1= YES ; 0= NO)

Default= 0

107

L

X

X

ACTIVE STOP (0=NO; 1=YES) 

Default= 1

108

N

X

X

BAUD RATE (3-4) [4800-9600]

Default= 4

109

L

X

PUMP LIFE RESET [Write “1” to Reset]

120

N

X

X

SET ROTATIONAL FREQUENCY [Hz]    150 Hz < = F_imp < = FMAX

121

N

X

X

MAX SETTABLE ROTATIONAL FREQUENCY [Hz]  F<=F_MAX_ABS

130

N

X

RAMP CURRENT [mA]

200

N

X

CURRENT [mA]

201

N

X

VOLTAGE[V]

202

N

X

POWER [W]

203

N

X

DRIVING FREQUENCY [Hz]

204

N

X

PUMP TEMPERATURE [°C]

205

N

X

STATUS  [0=stop; 1=interlock; 2=ramp; 3=regulation; 4=brake; 5=normal; 6=failure]

206

N

X

ERROR CODE:

Too high load                                                     

No connection

Short circuit                                                                     

Pump overtemp

SoftStart Not Ended                                                        

Controller overtemp

RunUpTime Not Reached                                                   

Power fail

211

N

X

PUMP SENSOR TEMPERATURE READING [208= 25°C - 128= 60°C]

216

N

X

AMBIENT SENSOR TEMPERATURE READING

300

N

X

CYCLE TIME [min]

301

N

X

CYCLE NUMBER

302

N

X

PUMP LIFE [h]

319

A

X

Controller Model

320

A

X

Base Pump Model Number (8 characters)

321

A

X

Modified  Standard Model Number (4 characters)

323

A

X

Controller Serial Number (5 characters)

325

A

X

Electrical Modification Level (10 characters)

400

A

X

CRC PROGRAM LISTING [QE7xxxx]

401

A

X

CRC BOOTLOADER [BL1xxxx]

402

A

X

CRC PARAMETER LISTING  [PA7xxxx]

404

A

X

CRC FILE PARAMETER STRUCTURE

406

A

X

PROGRAM LISTING CODE & REVISION

407

A

X

PARAMETER LISTING CODE & REVISION

500

L

X

MONITOR MODE

WIN

= Window

L

 = Logical

R

 

= Read

N

 = Numeric

W

 

= Write

A

 = Alphanumeric

 7

 0

Содержание Turbo-V 300 75 Vdc

Страница 1: ...87 900 939 01 D APRIL 2002 INSTRUCTION MANUAL Turbo V 300 75 Vdc Box Controller Model SQ 189 vacuum technologies...

Страница 2: ...Turbo V 300 75 Vdc Box Controller...

Страница 3: ......

Страница 4: ......

Страница 5: ...ump Connector 4 I O Specifications 4 9 pin D Type Connector Pin Assignement 4 Serial Communication Port 5 RS 232 Communication Descriptions 5 Transmission Channel Characteristics 5 Message Structure 5...

Страница 6: ...stand operation maintenance manuals and any additional information provided by Varian All warnings and cautions should be read carefully and strictly observed Address any safety operation and or maint...

Страница 7: ...and is composed of a PCB which includes all the circuitry necessary for its operation The microcomputer generates the variable output voltage according to the software and the gas load condition of th...

Страница 8: ...TECHNICAL INFORMATION 3 87 900 939 01 D CONTROLLER OUTLINE The outline dimension for the controller are shown in the following figure Controller outline...

Страница 9: ...ins A F Pump temperature sensor Pin E Ground I O Specifications START STOP START command STOP command Low 0 8 Vdc High 4 to 15 Vdc Analog output Output impedence Minimum load 0 to 10 Vdc proportional...

Страница 10: ...ommunication RS 232 serial port connections Transmission Channel Characteristics levels RS 232 RS 422 baud rate 9600 4800 programmable by a jumper on the board character length 8 bits parity none stop...

Страница 11: ...35 STX ADDR ACK ETX CRC Command SOFT START ON Source PC Destination Inverter 02 80 31 30 30 31 31 03 42 32 STX ADDR WINDOW WR ON ETX CRC Source Inverter Destination PC 02 80 06 03 38 35 STX ADDR ACK E...

Страница 12: ...4 brake 5 normal 6 failure 206 N X ERROR CODE Too high load No connection Short circuit Pump overtemp SoftStart Not Ended Controller overtemp RunUpTime Not Reached Power fail 211 N X PUMP SENSOR TEMPE...

Страница 13: ...9 pin D type connector To deactivate the Low Speed status it is necessary to disconnect pin 9 from pin 15 ground of the same connector The low speed frequency is equal to 622 Hz MAINTENANCE Replacemen...

Страница 14: ...TECHNICAL INFORMATION 9 87 900 939 01 D PCB JUMPERS...

Страница 15: ...TIFICATION Product Description Varian P N Varian S N Purchase Reference TYPE OF RETURN check appropriate box Paid Exchange Paid Repair Warranty Exchange Warranty Repair Loaner Return Credit Shipping E...

Страница 16: ...rate No zero high backround Gauge tube not working Display problem Vacuum system unstable Cannot reach test mode Communication failure Degas not working Failed to start Other Error code on display Oth...

Страница 17: ...an India PVT LTD 101 108 1st Floor 1010 Competent House 7 Nangal Raya Business Centre New Delhi 110 046 India Tel 91 11 5548444 Fax 91 11 5548445 Italy Varian Vacuum Technologies Via F lli Varian 54 1...

Отзывы: