Step 3. At last luminaire in link, install male termination connector at DATA THRU connector.
(Luminaires and other devices on the same DMX chain may not function properly without
termination.)
Figure 2-5: Data Link
Step 4. Connect AC Input Cable connector to power input source.
Step 5. Dress AC input and data cables and secure them so that they will not interfere with
luminaire head and yoke movement.
AC In
AC In
Data In
from console
Data Thru
Data Thru
Termination
AC In