background image

GE

Lighting Solutions

imagination at work

(BL44 and BL45 Series)

Features

• Long life (50,000 hour rated life)

• 5 year warranty

• IP30

Lumination

TM

 LED Luminaires

Installation Guide

BEFORE YOU BEGIN

Read these instructions completely and carefully.

Save These Instructions

Use only in the manner intended by the manufacturer. If you have any questions, contact the manufacturer.

 WARNING/AVERTISSEMENT

RISK OF ELECTRIC SHOCK

• Turn power off before inspection, installation or removal.
• Properly ground electrical enclosure.

RISK OF FIRE

• Follow all IEC and local codes.
• Use only UL or IEC approved wire for input/output connections. 

  Minimum size 18 AWG (0.82mm

2

).

• Product not IC rated.

RISQUES DE DÉCHARGES ÉLECTRIQUES

• Coupez l’alimentation avant d’’inspecter, installer ou déplacer le luminaire.
• Assurez-vous de correctement mettre à la terre le boîtier d’alimentation électrique.

RISQUES D’INCENDIE

• Respectez tous les codes IEC et codes locaux.
• N’utilisez que des fils approuvés par UL ou IEC pour les entrées/sorties de   

  connexion. Taille minimum 18 AWG (0.82mm

2

).

• Le produit n’est pas classé IC.

Prepare Electrical Wiring

Electrical Requirements

• The LED driver must be supplied with 100-277 VAC, 50/60 Hz and connected to an individual properly 

grounded branch circuit, protected by a 15 or 20 ampere circuit breaker. Use min. 75°C supply conductor.

Grounding Instructions

• The grounding and bonding of the overall system shall be done in accordance with National Electric Code 

(NEC) Article 600 and local codes.

Summary of Contents for Lumination BL44 Series

Page 1: ...2mm2 Product not IC rated RISQUES DE DÉCHARGES ÉLECTRIQUES Coupez l alimentation avant d inspecter installer ou déplacer le luminaire Assurez vous de correctement mettre à la terre le boîtier d alimentation électrique RISQUES D INCENDIE Respectez tous les codes IEC et codes locaux N utilisez que des fils approuvés par UL ou IEC pour les entrées sorties de connexion Taille minimum 18 AWG 0 82mm2 Le...

Page 2: ...r work gloves to prevent dirt and oil from being transferred to the luminaire Electrical Connections Dimming line optional AC line AC line 2 1 Connect the green wire of the AC line to the middle position on the terminal block Connect brown or black line wire to the L1 position and the blue neutral wire to the N position Loosen cable gland nuts to insert AC line Optionally insert dimming line into ...

Page 3: ...n re install end covers Luminaire Installation Follow diagram A for 0 10V or diagram B for DALI Run wires from controller through a different knockout than the AC input wire At output side of LED Driver make appropriate connections using twist on wire connectors Follow lighting controller installation instructions BLU WHT BLK WHT YEL GRY VIO VIO WHT LED Driver To 0 10V Dimmer 0 10V 0 10V BLU WHT B...

Page 4: ...emarks of the General Electric Company 2012 GE Lighting Solutions LLC Information provided is subject to change without notice All values are design or typical values when measured under laboratory conditions Specifications High Lumen Output Series Medium Lumen Output Series Input Voltage 120 277V 120 277V Input Power foot complete system 9W 6W Input Frequency 50 60Hz 50 60Hz Power Factor 0 9 0 9 ...

Reviews: