C
HAPTER
3. M
AINTENANCE
P
ROCEDURES
3-21
02.9631.0010
CONFIDENTIAL
15 Jan 98
Test x08 - Gobo Wheel with Sensor
When test X08 is executed, the gobo wheel is cycled until it encounters the
sensor. The wheel stops, rotates away from the sensor, and back again. If
the sensor is not detected, the wheel continues to cycle until the fault is
corrected or the test setting is changed.
Parameter settings for test X08 are as follows:
Parameter Test setting
Test Results
008
5 sec. spin reverse, 5 sec. spin forward
108
1 full spin reverse, 1 full spin forward
208
open white to half-way around wheel and
back
308
slow rotation with stop at each gobo
408
reverse rotation 5X; forward 5X
508
very slow reverse rotation
608
15 sec. 2X reverse, 15sec. 2X forward
708
step by step reverse rotation
808
stop at open white, no gobo
908
fast reverse rotation spin