background image

U

SER

 M

ANUAL

www.vareximaging.com

iii

2315NDT v2 CMOS X-ray Detector User Manual

Meaning of Alerts and Notes

Installation and Environment for Use

WARNING

This indicates a potentially hazardous situation which, if ignored, may 
result in severe personal injury, death, or substantial product damage.

Caution

This indicates a potentially hazardous situation which, if ignored, may 
result in minor or moderate personal injury or damage to the product.

Note

This emphasizes or supplements important information about the main 
text.

WARNING

The X-ray detector is intended to be installed, maintained, and used 
by qualified professional personnel who are trained and qualified in 
the installation, maintenance, and use of X-ray equipment.

WARNING

Do not operate the X-ray detector in or around flammable gases, gas 
mixtures, liquids, chemicals, or other substances. Ignoring this 
warning may result in explosion, fire, or electric shock, which may 
result in severe personal injury, death, or substantial product damage.

WARNING

Do not connect the X-ray detector to any component or accessory other 
than the manufacturer’s specified components and accessories.

Ignoring this warning may result in explosion, fire, or electric shock, 
which may result in severe personal injury, death, or substantial 
product damage.

WARNING

Do not modify or alter the X-ray detector, its components, or 
accessories.

Ignoring this warning may result in explosion, fire, or electric shock, 
which may result in severe personal injury, death, or substantial 
product damage.

WARNING

The detector is not designed to control X-ray dose. The system 
integrator is responsible for controlling the X-ray radiation.

Содержание 2315NDT

Страница 1: ...tector Before using the flat panel X ray detector please be sure to read these instructions thoroughly along with any other documentation provided for software and or other system components Keep thes...

Страница 2: ...essories This detector is not designated as a medical device It has been design and tested for industrial use only Protection Against Ionizing Radiation Exposure of any part of the human body to X rad...

Страница 3: ...WARNING Do not operate the X ray detector in or around flammable gases gas mixtures liquids chemicals or other substances Ignoring this warning may result in explosion fire or electric shock which ma...

Страница 4: ...ector into an X ray system shall ensure their installation plans avoid any physical penetration of the detector that could invalidate certifications Caution Do not operate the X ray detector in a loca...

Страница 5: ...cause electrical shock which may result in severe personal injury death or substantial product damage WARNING Do not modify the cables or subject the cable to external stress or damage Avoid placing...

Страница 6: ...ury death or substantial product damage WARNING If any abnormal condition such as smoke fumes or strange sound is evident turn off the X ray detector turn off and unplug the power supply from the AC o...

Страница 7: ...off the power switch or unplug the power supply cable from the AC outlet If the X ray detector is battery powered remove the battery Never use thinner benzine acetone or other flammable cleaning agen...

Страница 8: ...This page intentionally left blank viii www vareximaging com 2315NDT v2 CMOS X ray Detector User Manual...

Страница 9: ...ves and Regulations 9 12 0 Storage and Use 9 13 0 Description of the X ray Detector 10 13 1 Detector Functions 11 13 2 Embedded Features 11 13 3 Detector Design 11 13 4 Power Supply 12 13 5 Data Inter...

Страница 10: ...19 1 Readout Mode Continuous 26 19 1 1 Continuous Readout Software Trigger 27 19 1 2 Continuous Readout External Edge Trigger 30 19 1 3 Continuous Readout External Duration Trigger 31 19 1 4 Continuo...

Страница 11: ...Figure 10 Sync Connection for Edge Trigger 30 Figure 11 Continuous readout External Edge Trigger Timing 31 Figure 12 Continuous readout Duration Trigger Schematic 32 Figure 13 Sync Connection for Dura...

Страница 12: ...This page intentionally left blank xii www vareximaging com List of Figures 2315NDT v2 CMOS X ray Detector User Manual...

Страница 13: ...orage and Use Conditions 9 Table 7 Optional Accessories 14 Table 8 PC Requirement 15 Table 9 Sync Input Port specifications 16 Table 10 Sync Output Port specifications 16 Table 11 Power Supply Require...

Страница 14: ...This page intentionally left blank xiv www vareximaging com List of Tables 2315NDT v2 CMOS X ray Detector User Manual...

Страница 15: ...e 2315NDT CMOS X ray detector 2 0 Usage The Varex Imaging 2315NDT CMOS X ray Detector is a component of a digital imaging system for generating radiographic and dynamic images Final application is bas...

Страница 16: ...cument is for professional users from Original Equipment Manufacturers OEMs of X ray systems and X ray system installers who are responsible for installing the X ray detector into an X ray system Syst...

Страница 17: ...each sensor x 9 and x 1546 on the detector This will be marked as a defect column by default in the defective pixel map Offset image Typical offset image with visible readout line fully correctable Ty...

Страница 18: ...ious LFW Sensitivity HFW Available Available 2 times higher saturation level than legacy HFW 6 7 times higher saturation level than v2 LFW Temperature sensor Not available on the sensor but available...

Страница 19: ...Programming Interface BNC Bayonet Neill Concelman CL Camera Link DAQ Data acquisition EMC Electromagnetic Compatibility FOP Fiber Optic Plate FoV Field of View fps Frames per second HFW High full wel...

Страница 20: ...SI Software trigger SyncIn signal WEEE Waste electrical and electronic equipment Number Table 3 Documentation References Document Name Document Dexela X ray Detector Software Manual DX 001452 2315NDT...

Страница 21: ...ion which if ignored may result in severe personal injury death or substantial product damage Read the instruction manual Manufacturer s name and address Date of Manufacture YYYY MM where YYYY Year MM...

Страница 22: ...NDT v2 CMOS X ray Detector User Manual Indicates temperature limits within which the transport package shall be stored and handled The box bearing this symbol is recyclable Atmospheric pressure limita...

Страница 23: ...ement control and laboratory use Part 1 General requirements 2011 65 EUa 2015 863 a Detectors employ Lead as exempted under Annex III Item 13 a and Annex IV Item 5 Restriction of hazardous substances...

Страница 24: ...or Used in a Typical X ray Imaging System The detector does not function as a stand alone device It requires integration into an X ray system to produce images Synchronization ports on the detector fa...

Страница 25: ...n sensitivity and readout speed can be controlled on a frame by frame basis 13 3 Detector Design Varex Imaging CMOS detectors use CMOS image sensors The 2315NDT uses a sensor with 74 8 m pixel pitch T...

Страница 26: ...er Supply All Varex Imaging CMOS flat panel X ray detectors require a DC power supply For details of the power requirements see Section 16 0 Integration of the power supply into a final system is the...

Страница 27: ...sidiaries regional service headquarters listed in the last page of this manual Removal of either the X ray window or back panel of the detector will result in a violation of the limited warranty of th...

Страница 28: ...and are supplied for integration in X ray systems only Table 7 Optional Accessories Article No Description PT 001442 Camera Link Interface Card EPIX E8 PT 001063 Camera Link Data Cable 7 m PT 002040...

Страница 29: ...ngled connector up 1 5 m PT 001537 Camera Link Data Cable 90 angled connector up 1 3 m PT 001442 Camera Link Interface Card EPIX E8 Table 8 PC Requirement Computer requirement Processor Intel i5 Memor...

Страница 30: ...re is the positive terminal while the shell is the negative terminal Note The following instructions assume that the power supply and accesso ries supplied are those available as optional equipment fr...

Страница 31: ...ftware for instructions refer to the Dexela X ray Detector Software Manual 5 Connect the CL data cables between the detector and the frame grabber in the PC Connector 1 on the detector should be wired...

Страница 32: ...uncorrected image similar to Figure 4 should be visible Figure 4 Raw X ray Image 9 The image may appear too dark or too bright Move the cursor over the displayed image and note the pixel value that i...

Страница 33: ...ation menu select click Darks Enter the Exposure window and set the Quantity to 10 With the X ray beam off on the Tools menu click Collect Dark A set of 10 dark images is captured averaged and stored...

Страница 34: ...by clicking Snap 4 The result should be a clean looking image with no obvious background shading striping artifacts or lines as shown in Figure 5 Figure 5 Sample Image Note If the detector is moved o...

Страница 35: ...ould be acquired shortly before or after the acquisition of the image to be corrected and with the same integration time Linearity Correction Detector pixels have a slightly non linear response to lig...

Страница 36: ...ange without saturation for a general application In case of a specific application the acquired intensity should be in the dynamic range of the desired region of interest The Varex Imaging CMOS flat...

Страница 37: ...s Voltage Requirements Figure 6 shows the power connector s pin out scheme looking at the detector Figure 6 Power Connector s Pin Assignment WARNING Power supply voltages must be high enough to overco...

Страница 38: ...tand a continuous current of 40 A This can be achieved by installing an earth cable of at least 18 AWG conductor thicknesses which should be terminated with crimped ring terminals and secured with scr...

Страница 39: ...eximaging com 25 2315NDT v2 CMOS X ray Detector User Manual Figure 7 Cooling Airflow Note On the left correct air flow with baffles preventing re circulation On the right wrong air flow where air flow...

Страница 40: ...of Operation There are two readout modes available for 2315NDT panels Readout mode Continuous default mode In this mode the sensor is continuously reading out in the background the dark current so th...

Страница 41: ...e and read see Section 19 1 4 Sequence exposure see Section 19 1 5 Frame rate exposure see Section 19 1 6 Pre programmed exposure see Section 19 1 7 19 1 1 Continuous Readout Software Trigger In Softw...

Страница 42: ...nfigure the X ray to be active during TEW 7 After the detector s programmed exposure window TEW the frame is read out and transmitted to the PC SyncOuts levels go back to their initial values 8 The de...

Страница 43: ...d exposure window TEW so that the frame readout does not start before the X ray emission has finished The frame readout time and fps of 2315NDT detectors are shown in Table 13 Figure 9 shows an exampl...

Страница 44: ...2 level changes 5 At the same time the detector starts accumulating the image on the sensor 6 The user can configure the X ray to be active during TEW 7 After the detector s programmed exposure windo...

Страница 45: ...uously reading dark frames from the sensor 2 The end of the frame readout is reported by the pulses TBR coming from the SyncOuts with an interval TR O TD indicates the delay between the end of TBR and...

Страница 46: ...eadout cycle Figure 12 Continuous readout Duration Trigger Schematic Table 14 Duration Trigger specification for Continuous readout Symbol Description Value Notes TD Delay time 1 1 ms N A TR O Frame r...

Страница 47: ...the three trigger sources In SCap this is selected using Configuration Exposure Mode Normal Figure 14 Continuous readout Expose and read timing 19 1 5 Continuous Readout Sequence Exposure In Sequence...

Страница 48: ...see Figure 16 The minimum gap time is equivalent to the readout time The numbers of images the detector exposure time and the gap between exposures have to be previously set by software SCap or API D...

Страница 49: ...red on the sensor doesn t read out the dark current but waits for a request to come in to start the images acquisition In this way the synchronization between image request trigger and actual image ac...

Страница 50: ...e their status 4 The first image will contain all the dark currents accumulated from the detector since it was powered on so it will likely be noisier or even saturated and it will need to be discarde...

Страница 51: ...ay emission has finished The readout time and fps of 2315NDT detectors are shown in Table 13 on page 29 19 2 2 Idle Readout External Edge Trigger In External Edge Trigger the detector is triggered by...

Страница 52: ...dge Trigger behavior is similar to the Software one but the trigger signal comes from an external source and it is directed to the SyncIn port The timing specifications are the same as for Software Tr...

Страница 53: ...se and Read In Idle mode the first trigger will read out the accumulated dark current and then starts the exposure A second trigger is needed to read out the exposed image see Figure 20 Expose and rea...

Страница 54: ...utilize natural resources prudently and rationally Specific treatment of WEEE is indispensable in order to avoid the dispersion of pollutants into the recycled material or waste stream Such treatment...

Страница 55: ...USER M ANUAL www vareximaging com 41 2315NDT v2 CMOS X ray Detector User Manual 21 0 Appendix A Technical Drawings...

Страница 56: ...This page intentionally left blank 42 www vareximaging com 2315NDT v2 CMOS X ray Detector User Manual...

Страница 57: ...t 14 Disclaimer 1 discrepancies between v1 v2 sensors 2 Binning mode 3 Offset image 3 Readout column 3 Readout time 3 Sensitivity HFW 4 Sensitivity LFW 4 Sensor readout 3 Temperature sensor 4 Trigger...

Страница 58: ...X ray Detector User Manual Gain Correction 21 Linearity Correction 21 SCap Image Correction Functions 21 Scope 1 Servicing 13 Software Trigger 35 Standards Directives and Regulations 9 Storage and Us...

Страница 59: ...2315NDT v2 CMOS X ray Detector User Manual 45 This page intentionally left blank...

Страница 60: ...4 Varex Imaging All rights reserved The Varex Imaging logo and design are registered trademarks of Varex Imaging or its subsidiaries in the United States and other countries Paxscan is a registered tr...

Отзывы: