Stretch Valve 

Balloon tight

27 

26 

The Valve Balloon is not suit-

able for storing the aerosol  

for long periods, as it will con-

dense on the interior surface of the 

Balloon in time (a few hours). 
Inhale the contents of the Valve Bal-
loon within 10 minutes. 

Breathing Technique 
Inhale only half as much as possible. 
Hold your breath a few seconds and 
then breathe out slowly. 
We recommend consciously concen-
trating on your inhalation. The can-
nabinoid aerosol is absorbed by the 
alveoli and into the bloodstream. The 

onset of the effect takes approx. 1-2 

min. 

End of Inhalation 
Disconnect the power plug from the 
socket after inhalation.

6.  THE  USE OF DRONABINOL

7. THE USE OF HEMP FLOWERS 

Use only standardized, medicinal 
hemp flowers (cannabis flos) that 
have been tested by licensed produc-

ers for authenticity, purity, and patho-
gens according to the directives of the 
competent authorities in your country.   

Under no circumstances 

should you use cannabis from 
the illegal black market or any 

other cannabis that has not been sub-

jected to recognised quality controls. 

The amount of active ingredients in 

these products is generally unknown, 
may fluctuate considerably, and they 

often contain herbicides, fertilizers, 

bacteria, etc. 

7.1.  The Efficiency of Cannabi-

noids vaporized from Hemp 
Flowers (Cannabis Flos) 

By following the procedure listed in 
the Instructions for Use the systemic 
bioavailability of cannabinoids vapor-
ized from hemp flowers is approx. 29-

40%. 

For comparison: The systemic bio-
availability of cannabinoids aminis-
tered orally is below 15%. 

The following factors determine the 

cannbinoid concentration in the Valve 
Balloon: 

  Temperature - Higher vaporiza-

tion temperatures cause a higher 
cannbinoid concentration in the 

Valve Balloon, lower vaporiza-

tion temperatures cause a lower 
cannabinoid concentration in the 

Valve Balloon. 

  Quantity - Higher quantities in the 

Filling Chamber cause a higher 
cannbinoid concentration in the 

Valve Balloon, lower quantities in 

the Filling Chamber cause a lower 
cannabinoid concentration in the 

Valve Balloon. 

  Quality - Higher cannabinoid 

concentrations in the plant mate-
rial cause a higher cannabinoid 
concentration in the Valve Balloon, 

lower cannabinoid concentrations 
in the plant material cause a lower 

cannabinoid concentration in the 
Valve Balloon. 

To obtain a reproducible dosage with 

good efficiency, it is recommended to 
vaporize small quanitites (100 mg) in 

the Filling Chamber at top tempera-
ture (210°C/410°F) in a single Valve 
Balloon only.   

Содержание VOLCANO MEDIC

Страница 1: ...INSTRUCTIONS FOR USE Read carefully before using the device and save these instructions...

Страница 2: ...e and Transport Conditions 16 5 The VOLCANO MEDIC Hot Air Generator 17 5 1 Unpacking 17 5 2 Installation 17 5 3 Operation 17 5 4 Commissioning 18 5 5 Heating Up 18 5 6 Temperature Setting 19 6 The Use...

Страница 3: ...Filling Chamber Reusability of the Filling Chamber Reusability of the Valve Balloon Storage 9 5 Disassembly and Assembly 42 Filling Chamber Filling Chamber Cap Mouthpiece Disassembling the Filling Ch...

Страница 4: ...Pad 3 pcs Filling Chamber Clips not shown 1 pc Cap Ring not shown Please check whether all components have been included If not please inform our Service Center 1 PRODUCT OVERVIEW SCOPE OF DELIVERY S...

Страница 5: ...during installation use and maintenance of the VOLCANO MEDIC Vaporiza tion System Please keep this brochure in a safe place for future reference You may download the current version of the Instructio...

Страница 6: ...given on the type label on the bottom side of the Hot Air Generator cor responds to the mains supply at the place of installation If there are any problems during operation immediately pull out the po...

Страница 7: ...or should be cleaned only with a dry cloth or a damp cloth if absolutely necessary Never im merse the Hot Air Generator in water or in other liquids or clean it with a direct water or steam jet The Ho...

Страница 8: ...r responding laws Use only medicinal hemp flowers cannabis flos prescribed by your physician and purchased from a phar macy Otherwise you may be at risk of breaking the law In case of doubt ask your p...

Страница 9: ...and work properly If you notice any defects inform the seller or the delivery agent immediately The packing material plastic bags styrofoam material boxes etc must be kept out of the reach of children...

Страница 10: ...constantly maintained at the set value The luminous intensity of the yellow control lamp corresponds to the intensity of the heating process For technical reasons the temperature in the Filling Chamb...

Страница 11: ...10 C 410 F Cannabinoid content in blood stream systemic bioavailability after inhalation 6 THE USE OF DRONABINOL Preparation to use the Liquid Pad When using dronabinol THC dis solved in alcohol the S...

Страница 12: ...apter 9 5 Disassembling and As sembling the Filling Chamber page 42 Either the small Liquid Pad meas urements 15 x 5 mm or the Dosing Capsule containing a Liquid Pad measurements 13 x 6 mm are to be i...

Страница 13: ...button and shut off the air pump and remove the Valve Balloon together with the Filling Chamber To do so hold the Filling Chamber Cap at the textured grip 6 THE USE OF DRONABINOL 6 4 Inhalation from t...

Страница 14: ...uate considerably and they often contain herbicides fertilizers bacteria etc 7 1 The Efficiency of Cannabi noids vaporized from Hemp Flowers Cannabis Flos By following the procedure listed in the Inst...

Страница 15: ...ge is too high reduce the vaporization temperature Drug Filling Chamber Content Bedrocan 100 mg Bediol 100 mg THC approx 19 mg THC approx 6 mg CBD approx 7 5mg approx 8 mg approx 3 5 mg approx 4 5 mg...

Страница 16: ...ve Balloon tight Fill the Filling Chamber Reducer with ground hemp flowers directly or with a filled Dosing Capsule Take care that the Screens are not obstructed with plant material To guarantee opti...

Страница 17: ...ber to overheat and may cause burns When the Valve Balloon is filled switch off the air pump and remove the Valve Balloon together with the Filling Chamber To do so hold the Filling Chamber Cap at the...

Страница 18: ...the Dosing Capsule by using the Maga zine Cap funnel Dosing Capsules with Magazine With the Dosing Capsules which are available as accessories you can fill ground hemp flowers or dronabinol using the...

Страница 19: ...d Liquid Pad can be filled with up to 5 drops of dronabinol and store them in the Magazine Please make sure to not overfill the Liquid Pad 8 ACCESSORIES DOSING CAPSULES AND MAGAZINE The Dosing Capsule...

Страница 20: ...tor do not come in contact with the following chemicals organic mineral and oxidating acids min permissible pH 5 5 strong bases max permissible pH 10 We recommend using neutral enzymatic or slightly a...

Страница 21: ...rgent 9 HYGIENE Put the component parts of the Filling Chamber in a suit able place in the dishwasher Small parts e g Filling Chamber Clips can be lost or may damage the dishwasher if improperly place...

Страница 22: ...Disassembling the Filling Chamber Push the lower Screen or the Liquid Pad upwards out of the Filling Cham ber Cylinder Push the Filling Chamber Cylinder upwards out of the Filling Chamber Housing Pus...

Страница 23: ...hold the de vice under running water In a physician s office or clinic the housing of the Hot Air Generator can be cleaned and disinfected with a sur face disinfectant The surface disinfectant should...

Страница 24: ...OLCANO MEDIC display no activation of the heater or pump possible Please make sure that the current is on and that the fuse in the mains fuse box is switched on and is not defective If the Hot Air Gen...

Страница 25: ...self Contact directly our Service Center 10 7 Periodic Safety Checks The following safety checks should be performed at least every 24 months by a qualified person who has ade quate training knowledge...

Страница 26: ...ied below The customer or the user of the VOL CANO MEDIC Vaporization System should assure that it is used in such an en vironment Voltage dips short interruptions and voltage variations on power supp...

Страница 27: ...onment specified below The customer or the user of the VOL CANO MEDIC Vaporization System should assure that it is used in such an en vironment Where P is the maximum output power rating of the transm...

Страница 28: ...tomer or the user of the VOLCANO MEDIC Hot Air Generator can help prevent electro magnetic interference by maintaining a minimum distance between portable and mobile RF communications equipment transm...

Страница 29: ...ing Capsule Set 40 pcs REF 09 36 M MEDIC VALVE Magazine with 8 Dosing Capsule for Liquids REF 09 38 M MEDIC VALVE Dosing Capsules for Liquids Set 40 pcs REF 03 35 M MEDIC VALVE Liquid Pad Set for Dosi...

Страница 30: ...ring a new product to the customer Any warranty claims must be di rected to Storz Bickel GmbH In Gruben cker 5 9 78532 Tuttlingen Please send the complete defective item to us not disassembled with in...

Страница 31: ...Signature Name Title OK not OK OK not OK OK not OK OK not OK OK not OK OK not OK OK not OK OK not OK OK not OK OK not OK OK not OK OK not OK 61 60 13 WARRANTY LIABILITY REPAIR SERVICE 14 PROOF OF THE...

Страница 32: ...STORZ BICKEL GMBH CO KG In Gruben cker 5 9 78532 Tuttlingen Germany Phone 49 7461 969707 0 Fax 49 7461 969707 7 E Mail info vapormed com by STORZ BICKEL GmbH Co KG VMAL 50 213 EN 08 2017 Subject to al...

Отзывы: