background image

Vespera Instruction Manual v1.2 EN 2022-06                                                                                                            7 

Note:  
 

 

There  is a visual marker  with the  letter C located on the inside of  the f ilter f or easy 
identif ication when the  f ilter is not mounted on the  product.  

 

 

For optimal storage, we recommend storing the f ilter in its original plastic box.  

 

 

Cleaning  and maintenance  must be perf ormed with c aution. Only use wipes specif ically 
intended f or optical lenses.  

 

 

 
Vespera   AC022  Dual-Band  Filter 

 

 
Only handle  the f ilter by its edge to avoid dirtying or damaging it   
 
 

1.  Turn  the product on.  

 

2.  Connect to Vespera  via the  Singularity application.  

 

3.  In  the application, go to the "space center" page. 

 

4.  Go to "Instrument".  

 

5.  Press "open arm". The  arm will  open 180°. 

 

6.  Remove the  cover on the  f ront end of  the optical arm by pressing the button provided f or that 

purpose. 
 

7.  Position the AC022  dual-band f ilter. 

 

8.  If  properly assembled  

 

  a f ilter icon and the name  of  the f ilter, "DUAL", will appear under  the product image 

 

  initialize  the product and launch  an observation 

 

9.  If  improperly assembled or def ective  

 

  the f ilter icon will  not appear under  the product image, "no f ilter detected" will appear instead   

 

  remove the f ilter and reassemble.  If  the problem persists, contact support  

 
Note:  
 

 

There  is a visual marker  with the  letter D located on the inside of  the f ilter f or easy 
identif ication when the  f ilter is not mounted on the  product.  

 

 

For optimal storage, we recommend storing the f ilter in its original plastic box.  

 

 

Cleaning  and maintenance  must be perf ormed with caution. Only use wipes specif ically 
intended f or optical lenses.  

Содержание VESPERA

Страница 1: ...VESPERA VE50 Instruction Manual v1 2 EN 2022 02 ...

Страница 2: ... 4 Getting started 4 Connecting to Vespera 4 Control from the mobile app 5 How to turn Vespera off 5 VI Accessories optional 5 Hygrometer sensor AC024 5 Filtre Anti pollution lumineuse AC023 6 Filtre Dual Band AC022 7 Filtre Solaire AC021 8 VII Care and maintenance 9 VIII Transport and storage 9 IX Technical characteristics 10 X Warranty 11 XI Regulatory compliance 11 EU declaration of conformity ...

Страница 3: ... automatically It is equipped with a built in battery and can also be recharged by an AC adapter included if needed Once the telescopeis connected you can browse the mobileapp via your smartphone or tablet and choose an object from the suggestions Vespera can be controlled remotely thanks to the developed application and in a few minutes the telescope is ready to photograph Thanks to its integrate...

Страница 4: ...ratures between 0 C and 40 C Store the product in a clean and dry place preferably at room temperature and humidity less than 65 C Do not immerse the product in water Vespera is not a toy The product is not intended for use by children under the age of 14 This product may be used by children of at least 14 years of age and by persons with reduced physical sensory or mental capabilities or lack of ...

Страница 5: ...oduct is on the button changes from blue to green every 10 seconds when the product is charging It is recommended to perform this charging step indoors V Operation Getting started The button is tactile no need to apply strong pressure Charge the product to 100 before first use To start the instrument press the button on the side of the instrument The button flashes blue at first and then becomes s...

Страница 6: ...he side of the instrument The light on the button will go out indicating that Vespera is shut down VI Accessoires options Vespera AC024 Hygrometer Sensor Hygrometer sensor detection can take 30 seconds to 1 minute 1 Manually open the arm of the product 2 Remove the cover located on the front end of the optical arm by pressing the button provided for that purpose 3 Position the AC024 hygrometer sen...

Страница 7: ...ying or damaging it 1 Turn the product on 2 Connect to Vespera via the Singularity application 3 In the application go to the space center page 4 Go to Instrument 5 Press open arm The arm will open 180 6 Remove the cover on the front end of the optical arm by pressing the button provided for that purpose 7 Position the AC023 light pollution filter 8 If properly assembled a filter icon and the name...

Страница 8: ...ll open 180 6 Remove the cover on the front end of the optical arm by pressing the button provided for that purpose 7 Position the AC022 dual band filter 8 If properly assembled a filter icon and the name of the filter DUAL will appear under the product image initialize the product and launch an observation 9 If improperly assembled or defective the filter icon will not appear under the product im...

Страница 9: ...nter page 4 Click on Solar Pointing for the first observation read the information then press Close 5 Select your observatory 6 Press the start button the arm will open to 90 7 Remove the cover located on the front end of the optical arm by pressing the button provided for that purpose 8 Position the AC021 solar filter 9 If properly assembled a filter icon and the name of the filter SOLAR will app...

Страница 10: ...to contact with fingers cloths eyeglass cloths liquids etc Only specific wipes for optical lenses can be used The plastic shell can be cleaned with a soft cloth and soapy water Do not open the device under any circumstances Do not attempt to disassemble modify or repair the device as this will void the warranty and may cause the instrument to malfunction otherwise the warranty may be void and the ...

Страница 11: ...ith TPC slave without radar detection Bande de fréquence 5150 5350GHz Modulation 802 11 n ac Puissance maximale émise 21 84dBm EIRP Logiciel brcmfmac version 7 45 229 Mobile Application Singularity compatible with iOS and Android External devices 1 magnetic power supply Observations Deep sky objects galaxies nebulae star clusters Moon Sun with specific filter comets asteroids Warranty 2 years Opti...

Страница 12: ...air Vaonis is not responsible for damage caused by misuse of the product Damage due to improper use failure to follow these instructions or intervention by unauthorized persons is not covered by the warranty Failure or deterioration of the product due to normal wear and tear is not covered by this warranty If any warranty issues arise or if you need assistance in using your telescope contact suppo...

Страница 13: ...eceiver is connected The equipment must be installed and used with a minimum distance of 20cm between the radiation source and your body XII Disposal and recycling This symbol affixed to the product its packaging its instructions or other document or accessories of the product means that the product belongs to the family of electrical and electronic equipment It indicates that throughout the Europ...

Отзывы: