Vespera Instruction Manual v1.2 EN 2022-06 6
11. If properly assembled
the temperature and humidity icons will appear under the product image
initialize the product and launch an observation
12. If improperly assembled or def ective
the temperature and humidity icons will not appear under the product image, "no sensor
detected" will appear instead
Disassemble then reassemble the sensor. If the problem persists, contact support
Vespera AC023 Light Pollution Filter
Only handle the f ilter by its edge to avoid dirtying or damaging it
1. Turn the product on.
2. Connect to Vespera via the Singularity application.
3. In the application, go to the "space center" page.
4. Go to "Instrument".
5. Press "open arm". The arm will open 180°.
6. Remove the cover on the f ront end of the optical arm by pressing the button provided f or that
purpose.
7. Position the AC023 light pollution f ilter.
8. If properly assembled
a f ilter icon and the name of the f ilter, "CLS", will appear under the product image
initialize the product and launch an observation
9. If improperly assembled or def ective
the f ilter icon will not appear under the product image, "no f ilter detected" will appear instead
remove the f ilter and reassemble. If the problem persists, contact support