www.fmiproducts.com
113110-01K
32
SPECIFICATIONS
VMH26PRb
• Rating: 14,000/26,000 Btu/Hr
• Gas Type: Propane/LP Gas Only
• Ignition: Piezo
• Manifold Pressure: 8" W.C.
• Inlet Gas Pressure (in. of water):
Maximum: 14" W.C., Minimum*: 11" W.C.
• Dimensions (H x W x D): Fireplace (including
hood and screws) - 25
7
/
8
"
x 26
13
/
16
" x 9
3
/
8
"
Carton - 32
5
/
8
" x 27
13
/
16
" x 11
5
/
8
"
•
Weight: Fireplace - 44.5 lbs.
Shipping - 48 lbs.
* For purpose of input adjustment
VMH26NRb
• Rating: 14,000/26,000 Btu/Hr
• Gas Type: Natural Gas Only
• Ignition: Piezo
• Manifold Pressure: 3.5" W.C.
• Inlet Gas Pressure (in. of water):
Maximum: 10.5" W.C., Minimum*: 5" W.C.
• Dimensions (H x W x D): Fireplace (including
hood and screws) - 25
7
/
8
"
x 26
13
/
16
" x 9
3
/
8
"
Carton - 32
5
/
8
" x 27
13
/
16
" x 11
5
/
8
"
•
Weight: Fireplace - 44.5 lbs.
Shipping - 48 lbs.
* For purpose of input adjustment
SERVICE HINTS
When Gas Pressure Is Too Low
• pilot will not stay lit
• burners will have delayed ignition
• fireplace will not produce specified heat
• for propane/LP units, propane/LP gas sup
-
ply may be low
You may feel your gas pressure is too low. If
so, contact your local natural or propane/LP
gas supplier.
REPLACEMENT PARTS
Note: Use only original replacement parts.
This will protect your warranty coverage for
parts replaced under warranty.
Contact authorized dealers of this product.
If they can’t supply original replacement
part(s), call FMI PRODUCTS, LLC at
1-866-328-4537.
When calling, have ready:
• your name
• your address
• model and serial numbers of your heater
• how heater was malfunctioning
• purchase date
Usually, we will ask you to return the part to
the factory.
TECHNICAL SERVICES
You may have further questions about installa
-
tion, operation, or troubleshooting. If so, contact
FMI PRODUCTS, LLC at 1-866-328-4537.
When calling please have your model and serial
numbers of your heater ready.
You can also visit our web site at
www.fmiproducts.com
.