Vantage Hearth COMPACT CLASSIC HEARTH Скачать руководство пользователя страница 29

www.fmiproducts.com

113110-01K

29

POSSIbLE CAUSE

1. Control  knob  not  fully 

pressed in

2. Control knob not pressed 

in long enough

3. Safety  interlock  system 

has been triggered

4. Equipment  shutoff  valve 

not fully open

5. Pilot  flame  not  touching 

thermocouple,  which  al

-

lows thermocouple to cool, 
causing  pilot  flame  to  go 

out. This problem could be 
caused by one or both of 

the following:

  A) Low gas pressure

  B) Dirty or partially clogged 

ODS/pilot 

6. Thermocouple connection 

loose at control valve 

7. Thermocouple damaged
8. Control valve damaged

1. Inlet  gas  pressure  is  too 

low

2. Burner orifice is clogged

3. Thermopile leads discon-

nected or improperly con-
nected

4. Burners will not come on 

in remote position

1. Manifold  pressure  is  too 

low

2. Burner orifice is clogged

1. Burner orifice is clogged or 

damaged

2. Damaged burner

3. Gas regulator defective

4. Inlet  gas  pressure  is  too 

low

REMEDY

1. Press in control knob fully

2. After ODS/pilot lights, keep 

control knob pressed in 30 
seconds

3. Wait one minute for safety 

interlock  system  to  reset. 
Repeat ignition operation

4. Fully open equipment shut-

off valve

5. A) Contact local natural or 

propane/LP gas company

  B)  Clean  ODS/pilot  (see 

Cleaning and Maintenance,

 

page 26) or replace ODS/
pilot assembly

6. Hand  tighten  until  snug, 

then tighten 1/4 turn more

7. Replace pilot assembly
8. Replace control valve

1. Contact  local  natural  or 

propane/LP gas company

2. Clean burner (see 

Cleaning 

and Maintenance,

 page 26) 

or replace burner orifice

3. Reconnect leads (see 

Wir-

ing Diagram

, page 27)

4. Replace  battery  in  hand-

held remote and receiver

1. Contact  local  natural  or 

propane/LP gas company

2. Clean burner (see

 Cleaning 

and Maintenance

, page 26) 

or replace burner orifice

1. Clean burner (see

 Cleaning 

and Maintenance,

 page 26) 

or replace burner orifice

2. Replace damaged burner
3. Replace gas regulator
4. Contact  local  natural  or 

propane/LP gas company

ObSERVED PRObLEM

ODS/pilot  lights  but  flame 

goes  out  when  control  knob 

is released

Burner  does  not  light  after 
ODS/pilot is lit

Delayed ignition of burner

Burner  backfiring  during 
combustion

TROUBLESHOOTING

Continued

Содержание COMPACT CLASSIC HEARTH

Страница 1: ...switch do not use any phone in your building Immediatelycallyourgassupplierfromaneighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department...

Страница 2: ...is appliance is only for use with the type of gas indicated on the rating plate This appliance is not convertible for use with other gases Aftermarket Completion of sale not for purpose of resale from...

Страница 3: ...in the OFF position to prevent children from turning on burners with remote You must operate this fireplace withthefireplacescreeninplace Make sure fireplace screen is closed before running fireplace...

Страница 4: ...s that can be purchased separately wall switch hand held ON OFF remote wall thermostat hand held thermostat remote See Accessories page 33 Local Codes Install and use fireplace with care Follow all lo...

Страница 5: ...ludes one hardware packet Assembly Local Codes Continued 4 Check fireplace for any shipping dam age If heater is damaged call FMI PRODUCTS LLC at 1 866 328 4537 for replacement parts before returning...

Страница 6: ...w air from the house to operate You must provide adequate fresh air for these appliances This will insure proper venting of vented fuel burning appliances PROVIDING ADEQUATE VENTILATION The following...

Страница 7: ...gth x Width x Height __________cu ft volume of space Example Space size 16 ft length x 14 ft width x 8 ft ceiling height 1792 cu ft volume of space AIR FOR COMBUSTION AND VENTILATION Continued If addi...

Страница 8: ...o adjoining room see option 3 Figure 4 Follow the National Fuel Gas Code ANSI Z223 1 NFPA 54 Air for Combustion and Ventilation for required size of ventilation grills or ducts AIR FOR COMBUSTION AND...

Страница 9: ...ed to be used in zero clearance installations Wall or framing ma terial can be placed directly against any exterior surfaceontherear sides ortopofyourfireplace except where standoff spacers are integr...

Страница 10: ...in Figure 6 Example The face of a mantel bookshelf etc is made of combustible material and protrudes 3 1 2 from the wall This com bustible material must be 4 from the side of the fireplace opening see...

Страница 11: ...alve The flexible gas line must be the last item installed on the gas piping Nails or Wood Screws Nailing Flanges Figure 9 Attaching Fireplace to Wall Studs Wall Studs 4 If you have not assembled fire...

Страница 12: ...following raise the mantel to an accept able height remove the mantel Figure 10 Minimum Mantel Clearances for Built In Installation OPTIONAL MANTEL Installation Refer to instructions provided with th...

Страница 13: ...shoulder screws Align fireplace in mantel assembly so the trim overlaps mantel evenly on all three sides 12 Lower bottom louver door Use 3 wood screws provided with mantel accessory to attach firepla...

Страница 14: ...holes in the rear of the valve cover shieldandthroughtherectangularholeinthe front of shield see Figure 16 page 15 8 Reconnect red wire to switch position 3 Reconnect blue wire to switch position 1 Re...

Страница 15: ...witch Plate Blue Red Valve Cover Shield Snap Bushing Black Blower Mounting Holes Lower Louver Door Power Cord Figure 17 Wiring Diagram For Blower Accessory Standard Installation Red Red Fan Switch Aut...

Страница 16: ...lt In Installation WARNING A licensed elec trician must connect the wiring harness to electrical supply followingalllocalcodes Electri cianmustprovideaclamponthe box cover to secure the wiring Wirings...

Страница 17: ...If you do not reduce incoming gas pressure fireplace regulator damage could occur Install external regula tor with the vent pointing down as shown in Figure 21 Pointing the vent down protects it from...

Страница 18: ...re it is within reach for cleaning Install in piping system between fuel supply and heater Locate sediment trap where trapped matter is not likely to freeze Asediment trap traps moisture and contamina...

Страница 19: ...flame to check for a leak Apply a noncorrosive leak detection fluid toalljoints Bubblesformingshow a leak Correct all leaks at once CAUTION Make sure exter nal regulator has been installed betweenpro...

Страница 20: ...d Figure 28 Switch Plate and Wiring Harness Screw Switch Plate Black Wire Red Wire 3 Route 25 ft wire to a convenient location to mount your thermostat no outside wall IMPORTANT Wire may be short ened...

Страница 21: ...ically calibrated at the factory No adjustment or leveling is necessary optional Wall SWITCH GWMS2 WARNING Read and fol low installation instructions Installation should be done by a qualified install...

Страница 22: ...y appliance Do not touch any electric switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach...

Страница 23: ...lot with match To light pilot with match see Manual Lighting Procedure page 24 8 Keep control knob pressed in for 30 sec onds after lighting pilot After 30 seconds release control knob If control knob...

Страница 24: ...itch to the REMOTE position see Figure 36 Note The burner may light if hand held re mote was on when selector switch was last turned off You can now turn the burner on and off with the hand held remot...

Страница 25: ...pilot flame on natural gas units will have a slight curve but flame should be blue and have no yellow or orange color Figure 38 Correct Pilot Flame Pattern Propane LP Shown Pilot Burner Thermocouple...

Страница 26: ...tore hardware store or home center may carry compressed air in a can If using compressed air in a can please follow the directions on the can If you don t follow directions on the can you could dam ag...

Страница 27: ...ou remove one piece log set for clean ing refer to Installing Log Set and Screen page 22 for placement instructions Replace log set if broken or chipped dime sized or larger CABINET Air Passageways Us...

Страница 28: ...e in PILOT position 4 Air in gas lines when in stalled 5 Depleted gas supply pro pane LP only 6 ODS pilot is clogged 7 Gas regulator setting is not correct REMEDY 1 Reconnect ignitor cable 2 Free igni...

Страница 29: ...ontrol knob pressed in 30 seconds 3 Wait one minute for safety interlock system to reset Repeat ignition operation 4 Fully open equipment shut off valve 5 A Contact local natural or propane LP gas com...

Страница 30: ...line checked by local natural gas company 3 Observe minimum instal lation clearances see page 10 4 Clean burner see Cleaning and Maintenance page 26 or replace burner orifice 1 Turn fireplace off when...

Страница 31: ...ch your gas supplier call the fire department IMPORTANT Operating fireplace where impurities in air exist may create odors Cleaning supplies paint paint remover cigarette smoke cements and glues new c...

Страница 32: ...oo Low pilot will not stay lit burners will have delayed ignition fireplace will not produce specified heat for propane LP units propane LP gas sup ply may be low You may feel your gas pressure is too...

Страница 33: ...d CORNER MANTEL WITH Full HEARTH BASE C26TU Unfinished Traditional Design C26TO Oak Finished Traditional Design C26GO Oak Finished Georgian Design Space saving mantel and hearth base corner design fea...

Страница 34: ...oducts com 113110 01K 34 Parts MODELS VMH26PRB and VMH26NRB 39 37 38 4 22 40 32 11 28 30 12 7 35 25 10 9 7 23 1 2 20 20 8 14 8 24 33 34 13 41 21 26 18 15 27 20 3 20 29 16 18 3 17 42 36 6 4 20 19 31 31...

Страница 35: ...01 Injector 1 20 M11084 26 Screw Hex Head 10 x 3 8 25 21 098249 01 Nut M5 6 22 103781 01 Gas Valve 1 103781 02 Gas Valve 1 23 102639 01 Baffle 1 24 101628 01 Flexible Connector 1 25 104305 01 Control...

Страница 36: ...s product and or FMI PRODUCTS LLC who will provide original factory replacement parts Failure to use original factory replacement parts voids this warranty Travel handling transportation diagnostic ma...

Отзывы: