Vantage Hearth COMPACT CLASSIC HEARTH Скачать руководство пользователя страница 17

www.fmiproducts.com

113110-01K

17

INSTALLATION

Continued

Propane/LP 
Supply Tank

CONNECTING TO GAS SUPPLY

  WARNING:  This  appliance 

requires a 45° male flare fitting 

5/8"-18  UNF  (Unified  National 

Fine Thread) inlet connection and 

the flexible gas line provided.

  WARNING:  A  qualified 

service  person  must  connect 

fireplace to gas supply. Follow 

all local codes.

 WARNING: Never connect 

natural gas fireplace to private 

(non-utility)  gas  wells.  This 

gas  is  commonly  known  as 

wellhead gas.

IMPORTANT:

 For natural gas, check gas line 

pressure before connecting fireplace to gas 
line.  Gas  line  pressure  must  be  no  greater 
than 14" of water. If gas line pressure is higher, 

heater regulator damage could occur.

  CAUTION:  Never  connect 

propane/LP  fireplace  directly 

to the propane/LP supply. This 

fireplace  requires  an  external 

regulator (not supplied). Install 

the external regulator between 

the  fireplace  and  propane/LP 

supply.

For propane/LP units, the installer must supply 

an external regulator. The external regulator 

will reduce incoming gas pressure. You must 
reduce  incoming  gas  pressure  to  between 
11"  and  14"  of  water.  If  you  do  not  reduce 
incoming  gas  pressure,  fireplace  regulator 

damage could occur. Install external regula-

tor with the vent pointing down as shown in 
Figure 21. Pointing the vent down protects it 
from freezing rain or sleet.

Figure 21 - External Regulator With Vent 

Pointing Down

  CAUTION:  Use  only  new, 

black  iron  or  steel  pipe.  Inter

-

nally-tinned copper tubing may 

be used in certain areas. Check 

your  local  codes.  Use  pipe  of 

1/2" or greater diameter to allow 

proper gas volume to fireplace. 

If pipe is too small, undue loss 

of volume will occur.

Installation must include an equipment shutoff 

valve, union, and plugged 1/8" NPT tap. Lo

-

cate NPT tap within reach for test gauge hook 

up. NPT tap must be upstream from heater 

(see Figure 22, page 18).

IMPORTANT:

 Install equipment shutoff valve 

in  an  accessible  location.  The  equipment 
shutoff valve is for turning on or shutting off 
the gas to the appliance.
Check  your  building  codes  for  any  special 
requirements for locating equipment shutoff 

valve to fireplaces.
Apply pipe joint sealant lightly to male NPT 
threads. This will prevent excess sealant from 

going into pipe. Excess sealant in pipe could 

result in clogged fireplace valves.

  WARNING:  Use  pipe  joint 

sealant that is resistant to liquid 

petroleum (LP) gas.

External 
Regulator 

with Vent 

Pointing 

Down

Содержание COMPACT CLASSIC HEARTH

Страница 1: ...switch do not use any phone in your building Immediatelycallyourgassupplierfromaneighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department...

Страница 2: ...is appliance is only for use with the type of gas indicated on the rating plate This appliance is not convertible for use with other gases Aftermarket Completion of sale not for purpose of resale from...

Страница 3: ...in the OFF position to prevent children from turning on burners with remote You must operate this fireplace withthefireplacescreeninplace Make sure fireplace screen is closed before running fireplace...

Страница 4: ...s that can be purchased separately wall switch hand held ON OFF remote wall thermostat hand held thermostat remote See Accessories page 33 Local Codes Install and use fireplace with care Follow all lo...

Страница 5: ...ludes one hardware packet Assembly Local Codes Continued 4 Check fireplace for any shipping dam age If heater is damaged call FMI PRODUCTS LLC at 1 866 328 4537 for replacement parts before returning...

Страница 6: ...w air from the house to operate You must provide adequate fresh air for these appliances This will insure proper venting of vented fuel burning appliances PROVIDING ADEQUATE VENTILATION The following...

Страница 7: ...gth x Width x Height __________cu ft volume of space Example Space size 16 ft length x 14 ft width x 8 ft ceiling height 1792 cu ft volume of space AIR FOR COMBUSTION AND VENTILATION Continued If addi...

Страница 8: ...o adjoining room see option 3 Figure 4 Follow the National Fuel Gas Code ANSI Z223 1 NFPA 54 Air for Combustion and Ventilation for required size of ventilation grills or ducts AIR FOR COMBUSTION AND...

Страница 9: ...ed to be used in zero clearance installations Wall or framing ma terial can be placed directly against any exterior surfaceontherear sides ortopofyourfireplace except where standoff spacers are integr...

Страница 10: ...in Figure 6 Example The face of a mantel bookshelf etc is made of combustible material and protrudes 3 1 2 from the wall This com bustible material must be 4 from the side of the fireplace opening see...

Страница 11: ...alve The flexible gas line must be the last item installed on the gas piping Nails or Wood Screws Nailing Flanges Figure 9 Attaching Fireplace to Wall Studs Wall Studs 4 If you have not assembled fire...

Страница 12: ...following raise the mantel to an accept able height remove the mantel Figure 10 Minimum Mantel Clearances for Built In Installation OPTIONAL MANTEL Installation Refer to instructions provided with th...

Страница 13: ...shoulder screws Align fireplace in mantel assembly so the trim overlaps mantel evenly on all three sides 12 Lower bottom louver door Use 3 wood screws provided with mantel accessory to attach firepla...

Страница 14: ...holes in the rear of the valve cover shieldandthroughtherectangularholeinthe front of shield see Figure 16 page 15 8 Reconnect red wire to switch position 3 Reconnect blue wire to switch position 1 Re...

Страница 15: ...witch Plate Blue Red Valve Cover Shield Snap Bushing Black Blower Mounting Holes Lower Louver Door Power Cord Figure 17 Wiring Diagram For Blower Accessory Standard Installation Red Red Fan Switch Aut...

Страница 16: ...lt In Installation WARNING A licensed elec trician must connect the wiring harness to electrical supply followingalllocalcodes Electri cianmustprovideaclamponthe box cover to secure the wiring Wirings...

Страница 17: ...If you do not reduce incoming gas pressure fireplace regulator damage could occur Install external regula tor with the vent pointing down as shown in Figure 21 Pointing the vent down protects it from...

Страница 18: ...re it is within reach for cleaning Install in piping system between fuel supply and heater Locate sediment trap where trapped matter is not likely to freeze Asediment trap traps moisture and contamina...

Страница 19: ...flame to check for a leak Apply a noncorrosive leak detection fluid toalljoints Bubblesformingshow a leak Correct all leaks at once CAUTION Make sure exter nal regulator has been installed betweenpro...

Страница 20: ...d Figure 28 Switch Plate and Wiring Harness Screw Switch Plate Black Wire Red Wire 3 Route 25 ft wire to a convenient location to mount your thermostat no outside wall IMPORTANT Wire may be short ened...

Страница 21: ...ically calibrated at the factory No adjustment or leveling is necessary optional Wall SWITCH GWMS2 WARNING Read and fol low installation instructions Installation should be done by a qualified install...

Страница 22: ...y appliance Do not touch any electric switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach...

Страница 23: ...lot with match To light pilot with match see Manual Lighting Procedure page 24 8 Keep control knob pressed in for 30 sec onds after lighting pilot After 30 seconds release control knob If control knob...

Страница 24: ...itch to the REMOTE position see Figure 36 Note The burner may light if hand held re mote was on when selector switch was last turned off You can now turn the burner on and off with the hand held remot...

Страница 25: ...pilot flame on natural gas units will have a slight curve but flame should be blue and have no yellow or orange color Figure 38 Correct Pilot Flame Pattern Propane LP Shown Pilot Burner Thermocouple...

Страница 26: ...tore hardware store or home center may carry compressed air in a can If using compressed air in a can please follow the directions on the can If you don t follow directions on the can you could dam ag...

Страница 27: ...ou remove one piece log set for clean ing refer to Installing Log Set and Screen page 22 for placement instructions Replace log set if broken or chipped dime sized or larger CABINET Air Passageways Us...

Страница 28: ...e in PILOT position 4 Air in gas lines when in stalled 5 Depleted gas supply pro pane LP only 6 ODS pilot is clogged 7 Gas regulator setting is not correct REMEDY 1 Reconnect ignitor cable 2 Free igni...

Страница 29: ...ontrol knob pressed in 30 seconds 3 Wait one minute for safety interlock system to reset Repeat ignition operation 4 Fully open equipment shut off valve 5 A Contact local natural or propane LP gas com...

Страница 30: ...line checked by local natural gas company 3 Observe minimum instal lation clearances see page 10 4 Clean burner see Cleaning and Maintenance page 26 or replace burner orifice 1 Turn fireplace off when...

Страница 31: ...ch your gas supplier call the fire department IMPORTANT Operating fireplace where impurities in air exist may create odors Cleaning supplies paint paint remover cigarette smoke cements and glues new c...

Страница 32: ...oo Low pilot will not stay lit burners will have delayed ignition fireplace will not produce specified heat for propane LP units propane LP gas sup ply may be low You may feel your gas pressure is too...

Страница 33: ...d CORNER MANTEL WITH Full HEARTH BASE C26TU Unfinished Traditional Design C26TO Oak Finished Traditional Design C26GO Oak Finished Georgian Design Space saving mantel and hearth base corner design fea...

Страница 34: ...oducts com 113110 01K 34 Parts MODELS VMH26PRB and VMH26NRB 39 37 38 4 22 40 32 11 28 30 12 7 35 25 10 9 7 23 1 2 20 20 8 14 8 24 33 34 13 41 21 26 18 15 27 20 3 20 29 16 18 3 17 42 36 6 4 20 19 31 31...

Страница 35: ...01 Injector 1 20 M11084 26 Screw Hex Head 10 x 3 8 25 21 098249 01 Nut M5 6 22 103781 01 Gas Valve 1 103781 02 Gas Valve 1 23 102639 01 Baffle 1 24 101628 01 Flexible Connector 1 25 104305 01 Control...

Страница 36: ...s product and or FMI PRODUCTS LLC who will provide original factory replacement parts Failure to use original factory replacement parts voids this warranty Travel handling transportation diagnostic ma...

Отзывы: