PRESSURE TESTING FIREPLACE GAS
CONNECTIONS
1. Open equipment shutoff valve (see Figure
25, page 19).
2. Open main gas valve located on or near
gas meter for natural gas or open pro-
pane/LP supply tank valve.
3. Make sure control knob of fireplace is in
the OFF position.
4. Check all joints from equipment shutoff
valve to gas control valve (see Figures
26 or 27, page 19). Apply noncorrosive
leak detection fluid to all joints. Bubbles
forming show a leak.
5. Correct all leaks at once.
6. Light fireplace (see
Operation
,
page 22).
Check all other internal joints for leaks.
7. Turn off fireplace (see
To Turn Off Gas to
Appliance
, page 23).
OPTIONAL WIRELESS HAND-HELD
REMOTE CONTROL ACCESSORIES
(MRC AND TRC)
Installing Receiver
1. Remove screws.
2. Disconnect switch wires from control
valve.
3. Remove switch plate (see Figure 28).
Discard switch plate after removing. Save
the screws.
4. Place remote receiver unit onto fireplace
base.
5. Connect the wire harness from the re
-
ceiver to the TH and TH/TP terminals on
the valve.
6. For further information see installation
instructions provided with remote control
kit.
INSTALLATION
Continued
Figure 28 - Switch Plate and Wiring
Harness
Screw
Switch
Plate
Black
Wire
Red Wire
3. Route 25 ft. wire to a convenient location
to mount your thermostat (no outside
wall).
IMPORTANT:
Wire may be short-
ened but must not be lengthened.
Thermostat should be mounted 54" above
the floor in a location where there is good
air circulation. Avoid heat sources such as
lamps, direct sunlight, fireplace, or heat
and air conditioning ducts.
4. Gently remove thermostat cover from
base. Grasp sides of cover firmly and pull
to separate from base.
5.
Feed electrical wires through rectangular
slots on each side of base (see Figure 30).
OPTIONAL WALL MOUNTED
THERMOSTAT - GWMT1
WARNING: Read and fol-
low installation instructions.
Installation should be done by
a qualified installer familiar with
low-voltage wiring procedures.
WARNING: Do not connect
this thermostat to any electrical
source! Electrical shock and/or
fire hazard will occur.
1. Connect one terminal of 25 ft. wire to bot
-
tom contact of switch (see Figure 29).
2. Connect remaining wire terminal to “TH”
terminal on control valve. Make sure that
wire terminals are in the positions on your
unit as pictured in Figure 29. If wires are
not “crossed” thermostat will not work.
Figure 29 - Connecting Wire Terminals
AUT
O
OFF
ON
One Terminal
of 25 ft. Wire
Switch on Gas
Fireplace
To Wall Thermostat
or Switch
Control
Valve