Installation
ITC-Series
Inverter
Page 13
Owner’s Manual 8/5/17
G
N
D
OPTIONS TERMINAL STRIP
P14
HOT NEU GND
AC INPUT
P15
HOT NEU GND
AC OUTPUT
P6
P5
REMOTE MASTER AND
SLAVE CONNECTORS
R
E
M
O
T
E
S
W
IT
C
H
R
E
M
O
T
E
L
E
D
COM
N/O
N/O
LOW BATT/
FAN ON
COM
GENSTART
P3
BATTERY TEMP.
SENSOR
P7
F 10 Figure 1.4-9 Customer Terminations
DESCRIPTION OF OPERATION
Inverter
The System ON/OFF Switch, located on the front panel, allows the user to turn the system power ON and OFF
and to reset the system after a fault.
The Charger ON/OFF and Inverter ON/OFF buttons, located on the Control/Display Unit enable or disable the
Charger or Inverter Functions. The corresponding light next to Inverter/Charger buttons will be steadily on when
the unit is in the Inverter or Charger mode. These Inverter and Charger lights will blink if the mode is not
currently on, but are enabled (Example: The Inverter light will blink when the Inverter is Enabled, the ITC is
plugged into the utility, and the Charger is Active).
The Inverter AC Output Circuit Breaker is a 1 pole, 30-
amp breaker marked “CB-2” on the front unit. The CB-2
breaker protects the Inverter AC output and a second Breaker (CB-1) protects the Battery Charger AC input
against a severe overload. This CB-1 breaker also protects AC Pass through Power. If this CB-1 breaker trips
during charger operation, it must be reset.
Inverter Protective Interlocks
The Inverter operation is protected by a series of safety interlocks that protect against most failures such as
overloads, over-temperature conditions or other conditions where the unit may be asked to operate outside safe