Vanguard VP10T Скачать руководство пользователя страница 9

9

102489

OWNER’S MANUAL

Figure 15 - Checking Gas Joints

Propane/LP
Supply Tank

CHECKING GAS
CONNECTIONS

Manual
Shutoff
Valve

Control Valve Location

 WARNING: Test all gas pip-

ing and connections for leaks
after installing or servicing. Cor-
rect all leaks at once.

 WARNING: Never use an open

flame to check for a leak. Apply a
mixture of liquid soap and water
to all joints. Bubbles forming
show a leak. Correct all leaks at
once.

 CAUTION: Make sure exter-

nal regulator has been installed
between propane/LP supply and
heater. See guidelines under 

Con-

necting to Gas Supply, page 8.

PRESSURE TESTING GAS
SUPPLY PIPING SYSTEM

Test Pressures In Excess Of 1/2
PSIG

1.

Disconnect heater and its individual
manual shutoff valve from gas supply
piping system. Pressures in excess of
1/2 PSIG will damage heater regula-
tor.

2.

Cap off open end of gas pipe where
manual shutoff valve was connected.

3.

Pressurize supply piping system by ei-
ther using compressed air or opening
propane/LP supply tank valve.

4.

Check all joints of gas supply piping
system. Apply mixture of liquid soap
and water to gas joints. Bubbles form-
ing show a leak.

5.

Correct all leaks at once.

Test Pressures Equal To or
Less Than 1/2 PSIG

1.

Close manual shutoff valve (see Fig-
ure 14).

2.

Pressurize supply piping system by ei-
ther using compressed air or opening
propane/LP supply tank valve.

ON

POSITION

OFF

POSITION

Figure 14 - Manual Shutoff Valve

Manual
Shutoff Valve

Open

Closed

3.

Check all joints from propane/LP sup-
ply tank to manual shutoff valve (see
Figure 15). Apply mixture of liquid
soap and water to gas joints. Bubbles
forming show a leak.

4.

Correct all leaks at once.

PRESSURE TESTING
HEATER GAS
CONNECTIONS

1.

Open manual shutoff valve (see Figure
14).

2.

Open propane/LP supply tank valve.

3.

Make sure control knob of heater is in
the OFF position.

4.

Check all joints from manual shutoff
valve to control valve (see Figure 15).
Apply mixture of liquid soap and wa-
ter to gas joints. Bubbles forming show
a leak.

5.

Correct all leaks at once.

6.

Light heater (see Operating Heater,
pages 9 and 10). Check all other inter-
nal joints for leaks.

7.

Turn off heater (see To Turn Off Gas to
Appliance
, page 10).

8.

Replace front panel.

OPERATING
HEATER

FOR YOUR SAFETY
READ BEFORE
LIGHTING

A. This appliance has a pilot which must

be lighted by hand. When lighting the
pilot, follow these instructions ex-
actly.

B. BEFORE LIGHTING smell all

around the appliance area for gas. Be
sure to smell next to the floor because
some gas is heavier than air and will
settle on the floor.

WHAT TO DO IF YOU SMELL
GAS
• Do not try to light any appliance.
• Do not touch any electric switch;

do not use any phone in your build-
ing.

• Immediately call your gas supplier

from a neighbor’s phone. Follow
the gas supplier’s instructions.

• If you cannot reach your gas sup-

plier, call the fire department.

C. Use only your hand to push in or turn

the gas control knob. Never use tools.
If the knob will not push in or turn
by hand, don’t try to repair it, call a
qualified service technician or gas
supplier. Force or attempted repair
may result in a fire or explosion.

D. Do not use this appliance if any part

has been under water. Immediately
call a qualified service technician to
inspect the appliance and to replace
any part of the control system and
any gas control which has been un-
der water.

 WARNING: If you do not fol-

low these instructions exactly, a
fire or explosion may result caus-
ing property damage, personal
injury or loss of life.

Содержание VP10T

Страница 1: ...upplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installe...

Страница 2: ...instructions if you cannot reach your gas supplier call the fire department 4 Heater shall not be installed in a bath room 5 Never install the heater in a recreational vehicle where curtains furniture...

Страница 3: ...than ever New materials increased insulation and new construction methods help reduce heat loss in homes Home own ers weather strip and caulk around windows and doors to keep the cold air out and the...

Страница 4: ...s such as joints around window and door frames between sole plates and floors between wall ceil ing joints between wall panels at penetrations for plumbing electrical and gas lines and at other openin...

Страница 5: ...rk work sheet adding the space of the adjoining unconfined space The combined spaces must have enough fresh air to supply all appliances in both spaces Figure 3 Ventilation Air from Outdoors Outlet Ai...

Страница 6: ...ugh 5 INSTALLING TO WALL NOTICE A qualified service per son must install heater Follow all local codes CHECK GAS TYPE Useonlypropane LPgas Ifyourgassupply is not propane LP do not install heater Call...

Страница 7: ...igure 6 Folding Anchor Thin or Thick Wall thick wall shown Solid Wall 1 16 Space ANCHOR Placing Heater On Mounting Screws 1 Locate two keyhole slots on back panel of heater see Figure 9 2 Place large...

Страница 8: ...er connect heater directly to the propane LP supply This heater requires an external regulator not supplied Install the external regulator be tween the heater and propane LP supply Installsedimenttrap...

Страница 9: ...at once PRESSURE TESTING HEATER GAS CONNECTIONS 1 Open manual shutoff valve see Figure 14 2 Open propane LP supply tank valve 3 Make sure control knob of heater is in the OFF position 4 Check all join...

Страница 10: ...L O OF F H I Ignitor Button Control Knob LIGHTING INSTRUCTIONS 4 Wait five 5 minutes to clear out any gas Then smell for gas including near the floor If you smell gas STOP Follow B in the safety in fo...

Страница 11: ...ct Pilot Flame Pattern Figure 18 Correct Pilot Flame Pattern Thermocouple GRH OV 008 BAD PILOT LP If pilot flame pattern is incorrect as shown in Figure 19 turn heater off see To Turn Off Gas to Appli...

Страница 12: ...partially clogged ODS pilot 6 Thermocouple damaged 7 Control valve damaged REMEDY 1 Replace ignitor 2 Replace ignitor 3 Reconnect ignitor cable 4 Free ignitor cable if pinched by any metal or tubing K...

Страница 13: ...s see Cleaning and Maintenance page 11 or replace burner orifice s 2 Contact local propane LP gas company 3 Replace burner 4 Replace gas regulator 1 Replace burner 2 Contact local propane LP gas comp...

Страница 14: ...y tank 3 Locate and correct all leaks see Check ing Gas Connections page 9 1 Open window and or door for ventila tion 2 Contact local propane LP gas company 3 Clean ODS pilot see Cleaning and Maintena...

Страница 15: ...ty Contact authorized dealer from whom you purchased this product If they are unable to supply original replacement part s call DESAInternational sTechnicalServiceDe partment at 1 800 323 5190 for inf...

Страница 16: ...16 102489 PROPANE LP GAS HEATER VANGUARD VP10T 7 1 ODS PILOT 7 2 19 18 17 11 12 7 8 6 6 5 4 3 2 1 A B 15 16 16 14 10 13 9 ILLUSTRATED PARTS LIST VP10T...

Страница 17: ...rew Hex 8 x 1 4 10 7 099059 03 ODS Pilot Assembly 1 7 1 098514 01 Thermocouple 1 7 2 098594 01 Ignitor Electrode 1 8 099884 02 Burner Assembly 1 9 099056 01 Injector 2 10 102491 01 Tubing Burner 1 11...

Страница 18: ...______________________________ _______________________________________________________________________________________________ _________________________________________________________________________...

Страница 19: ...___________________ _______________________________________________________________________________________________ ____________________________________________________________________________________...

Страница 20: ...dsthiswarranty Theheater MUST be installed by a qualified installer in accordance with all local codes and instructions furnished with the unit This warranty does not apply to parts that are not in or...

Отзывы: