Vanguard VP10T Скачать руководство пользователя страница 8

8

102489

PROPANE/LP GAS HEATER

VANGUARD VP10T

IMPORTANT:

  Hold pressure regulator

with wrench when connecting it to gas pip-
ing and/or fittings.

Figure 13 - Gas Connection

*  An A.G.A. design-certified manual shutoff valve with 1/8" NPT tap is an acceptable
alternative to test gauge connection. Purchase the optional A.G.A. design-certified manual
shutoff valve from your dealer. See Accessory, page 15.

Tee Joint

Reducer
Bushing to
1/8" NPT

1/8" NPT
Plug Tap

Test
Gauge
Connection *

Tee
Joint

Pipe
Nipple

Cap

Pressure
Regulator

Heater
Cabinet

Ground Joint
Union

From External
Regulator
(11" W.C. to
14" W.C.
Pressure)

Manual
Shutoff
Valve *

3" Minimum

Sediment

Trap

CONNECTING TO
GAS SUPPLY

NOTICE: A qualified service per-
son must connect heater to gas
supply. Follow all local codes.

The installer must supply an external regu-
lator. The external regulator will reduce
incoming gas pressure. You must reduce
incoming gas pressure to between 11 and 14
inches of water. If you do not reduce incom-
ing gas pressure, heater regulator damage
could occur. Install external regulator with
the vent pointing down as shown in Figure
12. Pointing the vent down protects it from
freezing rain or sleet.

 CAUTION: Never connect

heater directly to the propane/LP
supply. This heater requires an
external regulator (not supplied).
Install the external regulator be-
tween the heater and propane/LP
supply.

Install sediment trap in supply line as shown
in Figure 13. Locate sediment trap where it
is within reach for cleaning. Locate sedi-
ment trap where trapped matter is not likely
to freeze. A sediment trap traps moisture
and contaminants. This keeps them from
going into heater controls. If sediment trap
is not installed or is installed wrong, heater
may not run properly.

Installation must include a manual shutoff
valve, ground joint union, and plugged  1/8"
NPT tap. Locate NPT tap within reach for
test gauge hook up. NPT tap must be up-
stream from heater (see Figure 13).

Apply pipe joint sealant lightly to male
threads. This will prevent excess sealant
from going into pipe. Excess sealant in pipe
could result in clogged heater valves.

Figure 12 - External Regulator With Vent
Pointing Down

 CAUTION: Use only new,

black iron or steel pipe. Inter-
nally-tinned copper tubing may
be used in certain areas. Check
your local codes. Use pipe 3/8"
diameter or greater to allow
proper gas volume to heater. If
pipe is too small, undue loss of
pressure will occur

Propane/
LP Supply
Tank

Vent
Pointing
Down

External
Regulator

 CAUTION: Use pipe joint seal-

ant that is resistant to liquid pe-
troleum (LP) gas.

3/8" NPT
Pipe
Nipple

Содержание VP10T

Страница 1: ...upplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installe...

Страница 2: ...instructions if you cannot reach your gas supplier call the fire department 4 Heater shall not be installed in a bath room 5 Never install the heater in a recreational vehicle where curtains furniture...

Страница 3: ...than ever New materials increased insulation and new construction methods help reduce heat loss in homes Home own ers weather strip and caulk around windows and doors to keep the cold air out and the...

Страница 4: ...s such as joints around window and door frames between sole plates and floors between wall ceil ing joints between wall panels at penetrations for plumbing electrical and gas lines and at other openin...

Страница 5: ...rk work sheet adding the space of the adjoining unconfined space The combined spaces must have enough fresh air to supply all appliances in both spaces Figure 3 Ventilation Air from Outdoors Outlet Ai...

Страница 6: ...ugh 5 INSTALLING TO WALL NOTICE A qualified service per son must install heater Follow all local codes CHECK GAS TYPE Useonlypropane LPgas Ifyourgassupply is not propane LP do not install heater Call...

Страница 7: ...igure 6 Folding Anchor Thin or Thick Wall thick wall shown Solid Wall 1 16 Space ANCHOR Placing Heater On Mounting Screws 1 Locate two keyhole slots on back panel of heater see Figure 9 2 Place large...

Страница 8: ...er connect heater directly to the propane LP supply This heater requires an external regulator not supplied Install the external regulator be tween the heater and propane LP supply Installsedimenttrap...

Страница 9: ...at once PRESSURE TESTING HEATER GAS CONNECTIONS 1 Open manual shutoff valve see Figure 14 2 Open propane LP supply tank valve 3 Make sure control knob of heater is in the OFF position 4 Check all join...

Страница 10: ...L O OF F H I Ignitor Button Control Knob LIGHTING INSTRUCTIONS 4 Wait five 5 minutes to clear out any gas Then smell for gas including near the floor If you smell gas STOP Follow B in the safety in fo...

Страница 11: ...ct Pilot Flame Pattern Figure 18 Correct Pilot Flame Pattern Thermocouple GRH OV 008 BAD PILOT LP If pilot flame pattern is incorrect as shown in Figure 19 turn heater off see To Turn Off Gas to Appli...

Страница 12: ...partially clogged ODS pilot 6 Thermocouple damaged 7 Control valve damaged REMEDY 1 Replace ignitor 2 Replace ignitor 3 Reconnect ignitor cable 4 Free ignitor cable if pinched by any metal or tubing K...

Страница 13: ...s see Cleaning and Maintenance page 11 or replace burner orifice s 2 Contact local propane LP gas company 3 Replace burner 4 Replace gas regulator 1 Replace burner 2 Contact local propane LP gas comp...

Страница 14: ...y tank 3 Locate and correct all leaks see Check ing Gas Connections page 9 1 Open window and or door for ventila tion 2 Contact local propane LP gas company 3 Clean ODS pilot see Cleaning and Maintena...

Страница 15: ...ty Contact authorized dealer from whom you purchased this product If they are unable to supply original replacement part s call DESAInternational sTechnicalServiceDe partment at 1 800 323 5190 for inf...

Страница 16: ...16 102489 PROPANE LP GAS HEATER VANGUARD VP10T 7 1 ODS PILOT 7 2 19 18 17 11 12 7 8 6 6 5 4 3 2 1 A B 15 16 16 14 10 13 9 ILLUSTRATED PARTS LIST VP10T...

Страница 17: ...rew Hex 8 x 1 4 10 7 099059 03 ODS Pilot Assembly 1 7 1 098514 01 Thermocouple 1 7 2 098594 01 Ignitor Electrode 1 8 099884 02 Burner Assembly 1 9 099056 01 Injector 2 10 102491 01 Tubing Burner 1 11...

Страница 18: ...______________________________ _______________________________________________________________________________________________ _________________________________________________________________________...

Страница 19: ...___________________ _______________________________________________________________________________________________ ____________________________________________________________________________________...

Страница 20: ...dsthiswarranty Theheater MUST be installed by a qualified installer in accordance with all local codes and instructions furnished with the unit This warranty does not apply to parts that are not in or...

Отзывы: