Vanguard VP10T Скачать руководство пользователя страница 2

2

102489

PROPANE/LP GAS HEATER

VANGUARD VP10T

SAFETY
INFORMATION

Carbon Monoxide Poisoning:

 Early

signs of carbon monoxide poisoning re-
semble the flu, with headaches, dizziness,
or nausea. If you have these signs, the heater
may not be working properly. Get fresh air
at once!
 Have heater serviced. Some people
are more affected by carbon monoxide than
others. These include pregnant women, per-
sons with heart or lung disease or anemia,
those under the influence of alcohol, and
those at high altitudes.

Propane/LP Gas:

 Propane/LP gas is odor-

less. An odor-making agent is added to
propane/LP gas. The odor helps you detect
a propane/LP gas leak. However, the odor
added to propane/LP gas can fade. Propane/
LP gas may be present even though no odor
exists.

Make certain you read and understand all
Warnings. Keep this manual for reference.
It is your guide to safe and proper operation
of this heater.

WARNING:

 Any change to this heater or

its controls can be dangerous.

1.

This appliance is only for use with the
type of gas indicated on the rating plate.
This appliance is not convertible for use
with other gases.

2.

Do not place propane/LP supply tank(s)
inside any structure. Locate propane/
LP supply tank(s) outdoors.

 WARNINGS

IMPORTANT: Read this Owner’s
Manual carefully and completely
before trying to assemble, oper-
ate, or service this heater. Im-
proper use of this heater can
cause serious injury or death from
burns, fire, explosion, and car-
bon monoxide poisoning.

 DANGER: Carbon monoxide

poisoning may lead to death!

3.

If you smell gas
• shut off gas supply
• do not try to light any appliance
• do not touch any electrical switch;

do not use any phone in your build-
ing

• immediately call your gas supplier

from a neighbor’s phone. Follow the
gas supplier’s instructions

• if you cannot reach your gas supplier,

call the fire department

4.

Heater shall not be installed in a bath-
room.

5.

Never install the heater
• in a recreational vehicle
• where curtains, furniture, clothing, or

other flammable objects are less than
36 inches from the front, top, or sides
of the heater

• as a fireplace insert
• in high traffic areas
• in windy or drafty areas

6.

This heater needs fresh, outside air ven-
tilation to run properly. This heater has
an oxygen depletion sensor (ODS) pi-
lot light safety system. The ODS shuts
down the heater if not enough fresh air
is available. See Air for Combustion
and Ventilation,
 pages 3 through 5.

7.

Keep all air openings in the front and
bottom of heater clear and free of de-
bris. This will insure enough air for
proper combustion.

8.

If heater shuts off, do not relight until
you provide fresh, outside air. If heater
keeps shutting off, have it serviced.

9.

Do not run heater
• where flammable liquids or vapors

are used or stored

• under dusty conditions

10. Never place any objects on the heater.

11. Surface of heater becomes very hot

when running heater. Keep children and
adults away from hot surface to avoid
burns and clothing ignition. Heater will
remain hot for a time after shutdown.
Allow surface to cool before touching.

12. Make sure grill guard is in place be-

fore running heater.

13. Carefully supervise young children

when they are in same room with
heater.

14. Do not use heater if any part has been

under water. Immediately call a quali-
fied service technician to inspect the
room heater and to replace any part of
the control system and any gas control
which has been under water.

15. Turn off heater and let cool before ser-

vicing. Only a qualified service person
should service and repair heater.

16. Operating heater above elevations of

4,500 feet could cause pilot outage.

17. To prevent performance problems, do

not use propane fuel tank of less than
100 lbs. capacity.

Содержание VP10T

Страница 1: ...upplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installe...

Страница 2: ...instructions if you cannot reach your gas supplier call the fire department 4 Heater shall not be installed in a bath room 5 Never install the heater in a recreational vehicle where curtains furniture...

Страница 3: ...than ever New materials increased insulation and new construction methods help reduce heat loss in homes Home own ers weather strip and caulk around windows and doors to keep the cold air out and the...

Страница 4: ...s such as joints around window and door frames between sole plates and floors between wall ceil ing joints between wall panels at penetrations for plumbing electrical and gas lines and at other openin...

Страница 5: ...rk work sheet adding the space of the adjoining unconfined space The combined spaces must have enough fresh air to supply all appliances in both spaces Figure 3 Ventilation Air from Outdoors Outlet Ai...

Страница 6: ...ugh 5 INSTALLING TO WALL NOTICE A qualified service per son must install heater Follow all local codes CHECK GAS TYPE Useonlypropane LPgas Ifyourgassupply is not propane LP do not install heater Call...

Страница 7: ...igure 6 Folding Anchor Thin or Thick Wall thick wall shown Solid Wall 1 16 Space ANCHOR Placing Heater On Mounting Screws 1 Locate two keyhole slots on back panel of heater see Figure 9 2 Place large...

Страница 8: ...er connect heater directly to the propane LP supply This heater requires an external regulator not supplied Install the external regulator be tween the heater and propane LP supply Installsedimenttrap...

Страница 9: ...at once PRESSURE TESTING HEATER GAS CONNECTIONS 1 Open manual shutoff valve see Figure 14 2 Open propane LP supply tank valve 3 Make sure control knob of heater is in the OFF position 4 Check all join...

Страница 10: ...L O OF F H I Ignitor Button Control Knob LIGHTING INSTRUCTIONS 4 Wait five 5 minutes to clear out any gas Then smell for gas including near the floor If you smell gas STOP Follow B in the safety in fo...

Страница 11: ...ct Pilot Flame Pattern Figure 18 Correct Pilot Flame Pattern Thermocouple GRH OV 008 BAD PILOT LP If pilot flame pattern is incorrect as shown in Figure 19 turn heater off see To Turn Off Gas to Appli...

Страница 12: ...partially clogged ODS pilot 6 Thermocouple damaged 7 Control valve damaged REMEDY 1 Replace ignitor 2 Replace ignitor 3 Reconnect ignitor cable 4 Free ignitor cable if pinched by any metal or tubing K...

Страница 13: ...s see Cleaning and Maintenance page 11 or replace burner orifice s 2 Contact local propane LP gas company 3 Replace burner 4 Replace gas regulator 1 Replace burner 2 Contact local propane LP gas comp...

Страница 14: ...y tank 3 Locate and correct all leaks see Check ing Gas Connections page 9 1 Open window and or door for ventila tion 2 Contact local propane LP gas company 3 Clean ODS pilot see Cleaning and Maintena...

Страница 15: ...ty Contact authorized dealer from whom you purchased this product If they are unable to supply original replacement part s call DESAInternational sTechnicalServiceDe partment at 1 800 323 5190 for inf...

Страница 16: ...16 102489 PROPANE LP GAS HEATER VANGUARD VP10T 7 1 ODS PILOT 7 2 19 18 17 11 12 7 8 6 6 5 4 3 2 1 A B 15 16 16 14 10 13 9 ILLUSTRATED PARTS LIST VP10T...

Страница 17: ...rew Hex 8 x 1 4 10 7 099059 03 ODS Pilot Assembly 1 7 1 098514 01 Thermocouple 1 7 2 098594 01 Ignitor Electrode 1 8 099884 02 Burner Assembly 1 9 099056 01 Injector 2 10 102491 01 Tubing Burner 1 11...

Страница 18: ...______________________________ _______________________________________________________________________________________________ _________________________________________________________________________...

Страница 19: ...___________________ _______________________________________________________________________________________________ ____________________________________________________________________________________...

Страница 20: ...dsthiswarranty Theheater MUST be installed by a qualified installer in accordance with all local codes and instructions furnished with the unit This warranty does not apply to parts that are not in or...

Отзывы: