3

102489

OWNER’S MANUAL

PRODUCT
IDENTIFICATION

PRODUCT
FEATURES

Safety Pilot

This heater has a pilot with an Oxygen
Depletion Sensor Shutoff System (ODS).
The ODS/pilot is a required feature for vent-
free room heaters. The ODS/pilot shuts off
the heater if there is not enough fresh air.

Piezo Ignition System

This heater has a piezo ignitor. This system
requires no matches, batteries, or other
sources to light heater.

LOCAL CODES

Install and use heater with care. Follow all
local codes. In the absence of local codes,
use the latest edition of National Fuel Gas
Code ANSI Z223.1, also known as NFPA
54*.

*Available from:

American National Standards Institute, Inc.

1430 Broadway

New York, NY  10018

National Fire Protection Association, Inc.

Batterymarch Park

Quincy, MA  02269

UNPACKING

1.

Remove heater from carton.

2.

Remove all protective packaging ap-
plied to heater for shipment.

3.

Check heater for any shipping damage.
If heater is damaged, promptly inform
dealer where you bought heater.

Heater
Cabinet

Grill Guard

Burners

Front Panel

Figure 1 - Model VP10T Vent-Free Propane/LP Gas Heater

Control Knob

Piezo Ignitor Button

AIR FOR
COMBUSTION AND
VENTILATION

Today’s homes are built more energy effi-
cient than ever. New materials, increased
insulation, and new construction methods
help reduce heat loss in homes. Home own-
ers weather strip and caulk around windows
and doors to keep the cold air out and the
warm air in. During heating months, home
owners want their homes as airtight as pos-
sible.

While it is good to make your home energy
efficient, your home needs to breathe. Fresh
air must enter your home. All fuel-burning
appliances need fresh air for proper com-
bustion and ventilation.

Exhaust fans, fireplaces, clothes dryers, and
fuel burning appliances draw air from the
house to operate. You must provide ad-
equate fresh air for these appliances. This
will insure proper venting of vented fuel-
burning appliances.

PROVIDING ADEQUATE
VENTILATION

The following is excerpts from National
Fuel Gas Code. NFPA 54/ANSI Z223.1,
Section 5.3, Air for Combustion and Venti-
lation.

All spaces in homes fall into one of the three
following ventilation classifications:

1. Unusually Tight Construction; 2. Uncon-
fined Space; 3. Confined Space.

The information on pages 4 and 5 will help
you classify your space and provide ad-
equate ventilation.

 WARNING: This heater shall

not be installed in a confined
space unless provisions are pro-
vided for adequate combustion
and ventilation air. Read the fol-
lowing instructions to insure
proper fresh air for this and other
fuel-burning appliances in your
home.

Continued

Содержание VP10T

Страница 1: ...upplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installe...

Страница 2: ...instructions if you cannot reach your gas supplier call the fire department 4 Heater shall not be installed in a bath room 5 Never install the heater in a recreational vehicle where curtains furniture...

Страница 3: ...than ever New materials increased insulation and new construction methods help reduce heat loss in homes Home own ers weather strip and caulk around windows and doors to keep the cold air out and the...

Страница 4: ...s such as joints around window and door frames between sole plates and floors between wall ceil ing joints between wall panels at penetrations for plumbing electrical and gas lines and at other openin...

Страница 5: ...rk work sheet adding the space of the adjoining unconfined space The combined spaces must have enough fresh air to supply all appliances in both spaces Figure 3 Ventilation Air from Outdoors Outlet Ai...

Страница 6: ...ugh 5 INSTALLING TO WALL NOTICE A qualified service per son must install heater Follow all local codes CHECK GAS TYPE Useonlypropane LPgas Ifyourgassupply is not propane LP do not install heater Call...

Страница 7: ...igure 6 Folding Anchor Thin or Thick Wall thick wall shown Solid Wall 1 16 Space ANCHOR Placing Heater On Mounting Screws 1 Locate two keyhole slots on back panel of heater see Figure 9 2 Place large...

Страница 8: ...er connect heater directly to the propane LP supply This heater requires an external regulator not supplied Install the external regulator be tween the heater and propane LP supply Installsedimenttrap...

Страница 9: ...at once PRESSURE TESTING HEATER GAS CONNECTIONS 1 Open manual shutoff valve see Figure 14 2 Open propane LP supply tank valve 3 Make sure control knob of heater is in the OFF position 4 Check all join...

Страница 10: ...L O OF F H I Ignitor Button Control Knob LIGHTING INSTRUCTIONS 4 Wait five 5 minutes to clear out any gas Then smell for gas including near the floor If you smell gas STOP Follow B in the safety in fo...

Страница 11: ...ct Pilot Flame Pattern Figure 18 Correct Pilot Flame Pattern Thermocouple GRH OV 008 BAD PILOT LP If pilot flame pattern is incorrect as shown in Figure 19 turn heater off see To Turn Off Gas to Appli...

Страница 12: ...partially clogged ODS pilot 6 Thermocouple damaged 7 Control valve damaged REMEDY 1 Replace ignitor 2 Replace ignitor 3 Reconnect ignitor cable 4 Free ignitor cable if pinched by any metal or tubing K...

Страница 13: ...s see Cleaning and Maintenance page 11 or replace burner orifice s 2 Contact local propane LP gas company 3 Replace burner 4 Replace gas regulator 1 Replace burner 2 Contact local propane LP gas comp...

Страница 14: ...y tank 3 Locate and correct all leaks see Check ing Gas Connections page 9 1 Open window and or door for ventila tion 2 Contact local propane LP gas company 3 Clean ODS pilot see Cleaning and Maintena...

Страница 15: ...ty Contact authorized dealer from whom you purchased this product If they are unable to supply original replacement part s call DESAInternational sTechnicalServiceDe partment at 1 800 323 5190 for inf...

Страница 16: ...16 102489 PROPANE LP GAS HEATER VANGUARD VP10T 7 1 ODS PILOT 7 2 19 18 17 11 12 7 8 6 6 5 4 3 2 1 A B 15 16 16 14 10 13 9 ILLUSTRATED PARTS LIST VP10T...

Страница 17: ...rew Hex 8 x 1 4 10 7 099059 03 ODS Pilot Assembly 1 7 1 098514 01 Thermocouple 1 7 2 098594 01 Ignitor Electrode 1 8 099884 02 Burner Assembly 1 9 099056 01 Injector 2 10 102491 01 Tubing Burner 1 11...

Страница 18: ...______________________________ _______________________________________________________________________________________________ _________________________________________________________________________...

Страница 19: ...___________________ _______________________________________________________________________________________________ ____________________________________________________________________________________...

Страница 20: ...dsthiswarranty Theheater MUST be installed by a qualified installer in accordance with all local codes and instructions furnished with the unit This warranty does not apply to parts that are not in or...

Отзывы: