PROPANE/LP GAS HEATER

VANGUARD VP10T

Figure 5 - Mounting Screw Locations

Mounting

Screw

Locations

10 7/8"

Minimum To

Maintain 8"

Clearance
From Wall

7 3/4"

20 1/4"

Minimum

To

Maintain 3"

Clearance

From Floor

FLOOR

JOINING WALL

36"

3"

FLOOR

CEILING

Minimum

Minimum 
Of Carpet
Combusti

8"

Minimum
From
Sides Of
Heater

Right
Side

Left
Side

LOCATING HEATER

This heater is designed to be mounted on a
wall.

 

 WARNING: Maintain the mini-

mum clearances shown in Figure
4. If you can, provide greater clear-
ances from floor, ceiling, and
joining wall.

 WARNING: Never install the

heater

• in a bathroom
• in a recreational vehicle
• where curtains, furniture,

clothing, or other flammable
objects are less than 36 inches
from the front, top, or sides of
the heater

• as a fireplace insert
• in high traffic areas
• in windy or drafty areas

 CAUTION: This heater cre-

ates warm air currents. These
currents move heat to wall sur-
faces next to heater. Installing
heater next to vinyl or cloth wall
coverings or operating heater
where impurities in the air (such
as tobacco smoke) exist, may
discolor walls.

IMPORTANT:

 Vent-free heaters add mois-

ture to the air. Although this is beneficial,
installing heater in rooms without enough
ventilation air may cause mildew to form
from too much moisture. See Air for Com-
bustion and Ventilation, 
pages 3 through 5.

INSTALLING TO
WALL

NOTICE: A qualified service per-
son must install heater. Follow
all local codes.

CHECK GAS TYPE

Use only propane/LP gas. If your gas supply
is not propane/LP, do not install heater. Call
dealer where you bought heater for proper
type heater.

INSTALLATION ITEMS

Before installing heater, make sure you have
the items listed below.

• external regulator (supplied by in-

staller, see page 8)

• piping (check local codes)
• sealant (resistant to propane/LP gas)
• manual shutoff valve *
• ground joint union
• test gauge connection * (see Figure

13, page 8)

• sediment trap
• tee joint
• pipe wrench

*  An A.G.A. design-certified manual shutoff
valve with 1/8" NPT tap is an acceptable
alternative to test gauge connection. The
optional A.G.A. design-certified manual
shutoff valve can be purchased from your
dealer. See Accessory, page 15.

2.

Mark two mounting screw locations on
wall (see Figure 5).

INSTALLING HEATER TO
WALL

Marking Screw Locations

1.

Determine where you will locate heater.

 WARNING: Maintain minimum

clearances shown in Figure 5. If
you can, provide greater clear-
ances from floor and joining wall.

For convenience and efficiency, install heater

• where there is easy access for opera-

tion, inspection, and service

• in coldest part of room

 CAUTION: If you install the

heater in a home garage

• heater pilot and burner must

be at least 18 inches above
floor

• locate heater where moving ve-

hicle will not hit it

Figure 4 - Mounting Clearances As Viewed
From Front of Heater

Minimum To
Top Surface
Of Carpeting,
Tile Or Other
Combustible
Material

Содержание VP10T

Страница 1: ...upplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installe...

Страница 2: ...instructions if you cannot reach your gas supplier call the fire department 4 Heater shall not be installed in a bath room 5 Never install the heater in a recreational vehicle where curtains furniture...

Страница 3: ...than ever New materials increased insulation and new construction methods help reduce heat loss in homes Home own ers weather strip and caulk around windows and doors to keep the cold air out and the...

Страница 4: ...s such as joints around window and door frames between sole plates and floors between wall ceil ing joints between wall panels at penetrations for plumbing electrical and gas lines and at other openin...

Страница 5: ...rk work sheet adding the space of the adjoining unconfined space The combined spaces must have enough fresh air to supply all appliances in both spaces Figure 3 Ventilation Air from Outdoors Outlet Ai...

Страница 6: ...ugh 5 INSTALLING TO WALL NOTICE A qualified service per son must install heater Follow all local codes CHECK GAS TYPE Useonlypropane LPgas Ifyourgassupply is not propane LP do not install heater Call...

Страница 7: ...igure 6 Folding Anchor Thin or Thick Wall thick wall shown Solid Wall 1 16 Space ANCHOR Placing Heater On Mounting Screws 1 Locate two keyhole slots on back panel of heater see Figure 9 2 Place large...

Страница 8: ...er connect heater directly to the propane LP supply This heater requires an external regulator not supplied Install the external regulator be tween the heater and propane LP supply Installsedimenttrap...

Страница 9: ...at once PRESSURE TESTING HEATER GAS CONNECTIONS 1 Open manual shutoff valve see Figure 14 2 Open propane LP supply tank valve 3 Make sure control knob of heater is in the OFF position 4 Check all join...

Страница 10: ...L O OF F H I Ignitor Button Control Knob LIGHTING INSTRUCTIONS 4 Wait five 5 minutes to clear out any gas Then smell for gas including near the floor If you smell gas STOP Follow B in the safety in fo...

Страница 11: ...ct Pilot Flame Pattern Figure 18 Correct Pilot Flame Pattern Thermocouple GRH OV 008 BAD PILOT LP If pilot flame pattern is incorrect as shown in Figure 19 turn heater off see To Turn Off Gas to Appli...

Страница 12: ...partially clogged ODS pilot 6 Thermocouple damaged 7 Control valve damaged REMEDY 1 Replace ignitor 2 Replace ignitor 3 Reconnect ignitor cable 4 Free ignitor cable if pinched by any metal or tubing K...

Страница 13: ...s see Cleaning and Maintenance page 11 or replace burner orifice s 2 Contact local propane LP gas company 3 Replace burner 4 Replace gas regulator 1 Replace burner 2 Contact local propane LP gas comp...

Страница 14: ...y tank 3 Locate and correct all leaks see Check ing Gas Connections page 9 1 Open window and or door for ventila tion 2 Contact local propane LP gas company 3 Clean ODS pilot see Cleaning and Maintena...

Страница 15: ...ty Contact authorized dealer from whom you purchased this product If they are unable to supply original replacement part s call DESAInternational sTechnicalServiceDe partment at 1 800 323 5190 for inf...

Страница 16: ...16 102489 PROPANE LP GAS HEATER VANGUARD VP10T 7 1 ODS PILOT 7 2 19 18 17 11 12 7 8 6 6 5 4 3 2 1 A B 15 16 16 14 10 13 9 ILLUSTRATED PARTS LIST VP10T...

Страница 17: ...rew Hex 8 x 1 4 10 7 099059 03 ODS Pilot Assembly 1 7 1 098514 01 Thermocouple 1 7 2 098594 01 Ignitor Electrode 1 8 099884 02 Burner Assembly 1 9 099056 01 Injector 2 10 102491 01 Tubing Burner 1 11...

Страница 18: ...______________________________ _______________________________________________________________________________________________ _________________________________________________________________________...

Страница 19: ...___________________ _______________________________________________________________________________________________ ____________________________________________________________________________________...

Страница 20: ...dsthiswarranty Theheater MUST be installed by a qualified installer in accordance with all local codes and instructions furnished with the unit This warranty does not apply to parts that are not in or...