background image

11

105604

OWNER’S MANUAL

For more information, visit www.desatech.com

INSTALLATION

Continued

Figure 20 - Inserting Firebox Into Cabinet
Mantel

34 3/4"

17 3/4"

33" (FB32CA and

NLFB32CA)

34 1/4" (FB32NCA and

NLFB32NCA)

Figure 21 - Rough Opening for Installing
in Wall

BUILT-IN FIREBOX
INSTALLATION

Built-in installation of this firebox involves
installing firebox into a framed-in enclosure.
This makes the front of firebox flush with
wall. If installing a mantel above the firebox,
but you must follow the clearances shown in
Figure 7, page 8. Follow the instructions
below to install the firebox in this manner.

1.

Frame in rough opening. Use dimen-
sions shown in Figure 21 for the rough
opening

If installing in a corner, use dimensions
shown in Figure 22 for the rough open-
ing. The height is 33" (FB32CA and
NLFB32C) or 34 

1

/

4

" (FB32NCA and

NLFB32NC), which is the same as the
wall opening in Figure 21.

,,,,,

,,,,,

QQQQQ

QQQQQ

¢¢¢¢¢

¢¢¢¢¢

,,,

,,,

,,,

,,,

,,,

QQQ

QQQ

QQQ

QQQ

QQQ

¢¢¢

¢¢¢

¢¢¢

¢¢¢

¢¢¢

Figure 19 - Location of Nailing Flanges

Nailing
Flanges

39 3/8"

27 7/8"

55 5/8"  

34 3/4"

Figure 22 - Rough Opening for Installing
in Corner

2.

Install gas piping to firebox location. This
installation includes an approved flexible
gas line (if allowed by local codes) after
the manual shutoff valve. The flexible
gas line must be the last item installed
on the gas piping. See Connecting to Gas
Supply 
in log set owner’s manual.

3.

Carefully set firebox in front of rough
opening with back of firebox inside wall
opening. 

IMPORTANT:

  If installing

Brass Trim Kit GA6090, see instruc-
tions included with brass trim accessory.
You must install shoulder screws now.

4.

If using GA3700 blower accessory
(Models FB32CA and NLFB32C
only), see Installing Blower Accessory
for built-in installationpage 8.

5.

Attach flexible gas line to log set. See
Connecting to Gas Supply in log set
owner’s manual.

6.

Carefully insert firebox into rough
opening.

4.

Place hearth base accessory against wall
at installation location. Cut an access
hole in hearth top to run flexible gas
line to firebox (see Figure 17, page 10).
Make sure to locate access hole so cabi-
net mantel will cover it when installed.

Note:

 You can secure base to floor us-

ing wood screws. Countersink screw
heads and putty over.

5.

Route flexible gas line through access
hole in hearth base.

6.

Center cabinet mantel on hearth base
(see Figure 18, page 10). Make sure
mantel is flush against wall.

7.

Break off nailing flanges (see Figure 19)
with hammer or pliers.

IMPORTANT: 

When installing Brass

Trim Kit, see instructions included with
mantel accessory.

8.

Place cardboard or other protective
material on top of hearth base. Care-
fully set firebox on protective material,
with back of firebox inside mantel
opening.

9.

Attach flexible gas line to log set. See
Connecting to Gas Supply in your log
set owner’s manual.

10. If installing GA3700 blower (FB32CA

and NLFB32C models only), route
blower electrical cord through bushing
included with blower accessory in right
side firebox support and bushing in side
access opening of firebox. Plug elec-
trical cord into electrical outlet. See
Installing Blower Accessory, page 8.

Continued

11. Carefully insert firebox into cabinet

mantel. Be careful not to scratch or
damage hearth base, cabinet mantel, or
any laminate trim on hearth base. Re-
move protective material from top of
hearth base and from front of firebox
(if any).

12. Install the trim after final finishing and/

or painting of wall. See instructions
included with mantel accessory for at-
taching brass trim.

13. Check all gas connections for leaks. See

Checking Gas Connections in log set
owner's manual.

Содержание LogMate FB32NCA

Страница 1: ...alteration service or maintenance can cause injury or property damage Refer to this manualforcorrectinstallationand operational procedures For as sistanceoradditionalinformation consult a qualified in...

Страница 2: ...o run properly See Air for Com bustion and Ventilation pages 4 through 6 9 Do not run firebox where flammable liquids or vapors are used or stored under dusty conditions 10 Do not use this firebox to...

Страница 3: ...anges Standoffs Models FB32NCA and NLFB32NC only Louvers Models FB32CA and NLFB32C only 12 1 2 2 3 4 1 1 2 9 3 4 4 5 8 2 1 2 6 32 3 16 33 11 16 Standoffs Models FB32NCA and NLFB32NC only Electrical Ac...

Страница 4: ...he following 1 Where the firebox will be located Al low for wall and ceiling clearances see Installation Clearances page 7 2 Everything needed to complete instal lation 3 These models CANNOT be instal...

Страница 5: ...bustion air from the outdoors and vents to the outdoors 4 Compare the maximum Btu Hr the space can support with the actual amount of Btu Hr used _____________________Btu Hr maximum the space can suppo...

Страница 6: ...must have enough fresh air to supply all appliances in both spaces Ventilation Air From Outdoors Provide extra fresh air by using ventilation grills or ducts You must provide two per manent openings...

Страница 7: ...hroom in a recreational vehicle where curtains furniture clothing or other flammable objects are less than 42 inches from the front top or sides of the firebox in high traffic areas in windy or drafty...

Страница 8: ...n Installation Figure8 RemovingScrewsfromFirebox Bottom Screws WARNING If there is a duplex electricaloutletinstalledintheright side of the bottom of the fireplace base area be sure that the electri c...

Страница 9: ...ation is re cessed and or pre wired see Built In Installation of Blower Accessory column 2 8 Turn on power to duplex outlet if previ ouslyturnedoffperthewarninginstep1 9 Check to make sure that the po...

Страница 10: ...hrough nine rings lo cated at top of screen 2 Insert first rod into rear hole in left side of firebox Fasten rod to rear hole near center of firebox using black shoulder screw 3 Insert other rod into...

Страница 11: ...t in installation page 8 5 Attach flexible gas line to log set See Connecting to Gas Supply in log set owner s manual 6 Carefully insert firebox into rough opening 4 Place hearth base accessory agains...

Страница 12: ...SA International s Techni cal Service Department at 1 800 DESA LOG 1 800 337 2564 When calling DESA International have ready your name your address model and serial numbers of your firebox how firebox...

Страница 13: ...0 7 8 x 48 3 4 x 34 5 8 LAMINATE TRIM FOR HEARTH OR MANTEL G3002J Jade Marble Laminate Mantel Trim G3003J Jade Marble Laminate Hearth Base Trim G3002S Sandstone Marble Laminate Mantel Trim G3003S Sand...

Страница 14: ...LogMate FIREBOX For more information visit www desatech com ILLUSTRATED PARTS BREAKDOWN FB32NCA NLFB32NC Not Included with Model NLFB32NC 5 14 16 16 16 13 15 17 17 17 16 6 1 16 7 16 18 10 8 20 12 19...

Страница 15: ...6 103208 01 103208 01 Outer Shell Base 1 7 103245 01 101838 02 Firebox Wrapper 1 8 103297 01 103297 01 Assembly Screen 2 9 103217 01CK 103217 01CK Hood 1 10 103773 02CK 103773 02CK Front Assembly 1 11...

Страница 16: ...32 LogMate FIREBOX For more information visit www desatech com ILLUSTRATED PARTS BREAKDOWN FB32CA NLFB32C 5 16 16 15 16 17 22 6 1 16 7 16 14 21 13 18 10 8 20 12 19 9 4 2 3 2 16 11 18 18 Not Included...

Страница 17: ...245 01 101838 02 Firebox Wrapper 1 8 103297 01 103297 01 Assembly Screen 2 9 103217 01CK 103217 01CK Hood 1 10 103773 01CK 103773 01CK Front Assembly 1 11 103250 01 103250 01 Firebox Bottom 1 12 10380...

Страница 18: ...ring a defective heater will be the responsibility of the owner TOTHEFULLEXTENTALLOWEDBYTHELAWOFTHEJURISDICTIONTHATGOVERNSTHESALEOFTHEPRODUCT THIS EXPRESS WARRANTY EXCLUDES ANY AND ALL OTHER EXPRESSED...

Отзывы: