background image

15

105604

OWNER’S MANUAL

For more information, visit www.desatech.com

PARTS LIST

FB32NCA
NLFB32NC

This list contains replaceable parts used in your firebox. When ordering parts, follow the instructions
listed under Replacement Parts on page 12 of this manual.

KEY

PART NUMBER

NO.

FB32NCA

NLFB32NC

DESCRIPTION

QTY.

1

101872-03

101872-03

Firebox Top

1

2

101889-01

       *

Firebrick Retainer

3

3

101929-02

       *

Rear Firebrick

1

4

101932-02

       *

Side Firebrick

2

5

103207-01

103207-01

Outer Casing

1

6

103208-01

103208-01

Outer Shell Base

1

7

103245-01

101838-02

Firebox Wrapper

1

8

103297-01

103297-01

Assembly Screen

2

9

103217-01CK

103217-01CK

Hood

1

10

103773-02CK

103773-02CK

Front Assembly

1

11

103250-01

103250-01

Firebox Bottom

1

12

103809-01

103809-01

Screen Rod

2

13

103816-01

103816-01

Firebox Insulation

1

14

101348-01

101348-01

Firebox Support

2

15

101357-03

101357-03

Outer Casing Top

1

16

M11084-26

Hex Head Screw, #10-16

49

M11084-26

Hex Head Screw, #10-16

46

17

098194-02

098194-02

Stand Off

3

18

098304-01

098304-01

Phillips Pan Head Screw, #10

13

19

099230-01

099230-01

Hex Head Screw

3

20

099230-02

099230-02

Shoulder Screw

2

*Not Included with Model NLFB32NC

Содержание LogMate FB32NCA

Страница 1: ...alteration service or maintenance can cause injury or property damage Refer to this manualforcorrectinstallationand operational procedures For as sistanceoradditionalinformation consult a qualified in...

Страница 2: ...o run properly See Air for Com bustion and Ventilation pages 4 through 6 9 Do not run firebox where flammable liquids or vapors are used or stored under dusty conditions 10 Do not use this firebox to...

Страница 3: ...anges Standoffs Models FB32NCA and NLFB32NC only Louvers Models FB32CA and NLFB32C only 12 1 2 2 3 4 1 1 2 9 3 4 4 5 8 2 1 2 6 32 3 16 33 11 16 Standoffs Models FB32NCA and NLFB32NC only Electrical Ac...

Страница 4: ...he following 1 Where the firebox will be located Al low for wall and ceiling clearances see Installation Clearances page 7 2 Everything needed to complete instal lation 3 These models CANNOT be instal...

Страница 5: ...bustion air from the outdoors and vents to the outdoors 4 Compare the maximum Btu Hr the space can support with the actual amount of Btu Hr used _____________________Btu Hr maximum the space can suppo...

Страница 6: ...must have enough fresh air to supply all appliances in both spaces Ventilation Air From Outdoors Provide extra fresh air by using ventilation grills or ducts You must provide two per manent openings...

Страница 7: ...hroom in a recreational vehicle where curtains furniture clothing or other flammable objects are less than 42 inches from the front top or sides of the firebox in high traffic areas in windy or drafty...

Страница 8: ...n Installation Figure8 RemovingScrewsfromFirebox Bottom Screws WARNING If there is a duplex electricaloutletinstalledintheright side of the bottom of the fireplace base area be sure that the electri c...

Страница 9: ...ation is re cessed and or pre wired see Built In Installation of Blower Accessory column 2 8 Turn on power to duplex outlet if previ ouslyturnedoffperthewarninginstep1 9 Check to make sure that the po...

Страница 10: ...hrough nine rings lo cated at top of screen 2 Insert first rod into rear hole in left side of firebox Fasten rod to rear hole near center of firebox using black shoulder screw 3 Insert other rod into...

Страница 11: ...t in installation page 8 5 Attach flexible gas line to log set See Connecting to Gas Supply in log set owner s manual 6 Carefully insert firebox into rough opening 4 Place hearth base accessory agains...

Страница 12: ...SA International s Techni cal Service Department at 1 800 DESA LOG 1 800 337 2564 When calling DESA International have ready your name your address model and serial numbers of your firebox how firebox...

Страница 13: ...0 7 8 x 48 3 4 x 34 5 8 LAMINATE TRIM FOR HEARTH OR MANTEL G3002J Jade Marble Laminate Mantel Trim G3003J Jade Marble Laminate Hearth Base Trim G3002S Sandstone Marble Laminate Mantel Trim G3003S Sand...

Страница 14: ...LogMate FIREBOX For more information visit www desatech com ILLUSTRATED PARTS BREAKDOWN FB32NCA NLFB32NC Not Included with Model NLFB32NC 5 14 16 16 16 13 15 17 17 17 16 6 1 16 7 16 18 10 8 20 12 19...

Страница 15: ...6 103208 01 103208 01 Outer Shell Base 1 7 103245 01 101838 02 Firebox Wrapper 1 8 103297 01 103297 01 Assembly Screen 2 9 103217 01CK 103217 01CK Hood 1 10 103773 02CK 103773 02CK Front Assembly 1 11...

Страница 16: ...32 LogMate FIREBOX For more information visit www desatech com ILLUSTRATED PARTS BREAKDOWN FB32CA NLFB32C 5 16 16 15 16 17 22 6 1 16 7 16 14 21 13 18 10 8 20 12 19 9 4 2 3 2 16 11 18 18 Not Included...

Страница 17: ...245 01 101838 02 Firebox Wrapper 1 8 103297 01 103297 01 Assembly Screen 2 9 103217 01CK 103217 01CK Hood 1 10 103773 01CK 103773 01CK Front Assembly 1 11 103250 01 103250 01 Firebox Bottom 1 12 10380...

Страница 18: ...ring a defective heater will be the responsibility of the owner TOTHEFULLEXTENTALLOWEDBYTHELAWOFTHEJURISDICTIONTHATGOVERNSTHESALEOFTHEPRODUCT THIS EXPRESS WARRANTY EXCLUDES ANY AND ALL OTHER EXPRESSED...

Отзывы: