![Vamoose KT-LCD7 Скачать руководство пользователя страница 17](http://html1.mh-extra.com/html/vamoose/kt-lcd7/kt-lcd7_user-manual_3317130017.webp)
ELECTRIC BICYCLE METER KT
—
LCD7 Product User Manual
- 16 -
Under each setting interface, if there’s no button operation on the meter for more than
1 minute, and then the meter will automatically return to display 1, and the original set
parameters will be saved.
P Parameter Setting
After finishing metric/imperial unit settings, the speed and mileage units stop flashing.
Within one minute after stopping flashing, hold
button
(UP)
and
button
(DOWN)
simultaneously for about 2 seconds to enter P parameter setting environment.
○
P1 Motor Characteristic Parameter Setting
P1 is motor characteristic parameter setting, P1 = motor gear reduction ratio× number
of rotor magnet pieces, just rounding if there’s any decimal.
After entering P parameter setting environment, the first is to set P1parameter, P1
parameter column flashes. P1 setting ranges between1-255, hold
button (
UP
) or
button (
DOWN
) shortly for selection.
P1 parameter setting interface
Under P1 parameter setting interface, if there’s no button operation on the
meter for more than 1 minute, and then the meter will automatically return to display
1, and the original set parameter will be saved.
After finishing P1 parameter setting, hold
button shortly to save the current set
values and enter P2 parameter setting interface.
○
P2 Wheel Speed Pulse Signal Setting
Enter P2 parameter setting interface after P1 parameter setting is finished, and P2
parameter column flashes.