45
3.4.7.4. Refill duration time settings
Use keys UP „▲” and DOWN „▼” to change values and the key SET „■” to save modifications. The
following window will appear after saving modifications:
When pressing the key MENU „ ” of the valve, this one will return to the previous menu. If during 1
minute no key is to be pressed, the valve will return to the stand-by menu. Any modified value will return
to the initial value if not saved by means of SET „■” key.
3.4.7.5. Select regeneration mode
In this window you may choose the regeneration mode that is the most appropriate to your needs.
Use keys UP „▲” and DOWN „▼” to select the desired parameter and the key SET „■” to confirm the
selected parameter. Press key MENU „ ” to return to the previous menu.
Timer (Time regeneration)
– the station will initiate regeneration on the set hour and on the date resulting
further to the set number of days for the regeneration cycle.
Meter immediate (Immediate volumetric regeneration)
– the station will initiate regeneration immediately
after the water volume that may be treated between two regenerations is consumed.
Meter delayed (Delayed volumetric regeneration)
– when the quantity that may be treated until the next
regeneration reached 0, the station will initiate regeneration on the set hour (02:00 AM hours asset in the
factory).
Mix regeneration
- when the quantity that may be treated until the next regeneration reached 0, the
station will initiate regeneration on the first occasion, on the set hour; if the number of set days is reached
prior to the moment when the water quantity that may be treated between two regenerations reaches 0,
then the station will initiate regeneration.
In the the factory the stations are set to the
Mix regeneration mode
. It is recommended to maintain this
regeneration mode.
3.4.7.6. Restore factory default settings
Press the key SET „■”, to return to settings made in the factory. By pressing the key MENU „ ” of the
valve, this one will return to the previous menu. If during 1 minute no key is to be pressed, the valve will
return to the stand-by menu. Any modified value will return to the initial value if not saved by means of
SET „■” key.
4. P
꞊꞊꞊꞊꞊Refill Duration꞊꞊꞊꞊꞊
00 minutes
Press to Return
Press
■
to Confirm
!
This parameter is NOT to be modified;
In case the station does not operate appropriately, you should contact the staff of
S.C. Valrom Industrie S.R.L.
꞊꞊꞊꞊꞊Regen. Mode꞊꞊꞊꞊꞊
Timer
Meter Immediate
Meter Delayed
Mix Regen
Load Default
Press to cancel
Press
■
to confirm
Содержание aquaPUR MIX 25
Страница 107: ...107 2 2 1 2 2 1 4 100 12 1 4 2 3 12 99 5 NaCl 2 4 2 5 service bypass 3 5 12 12 22...
Страница 118: ...118 0 3 4 7 6 Restore factory default settings SET MENIU 1 SET Load Default Press to cancel Press to confirm Valrom...
Страница 122: ...122 4 4 4 09 00 CC 07 09 00 MI 01 12T 09 00 MD 01 12T 09 00 MO 01 12T...
Страница 125: ...125 4 5 1 1 1 2 2 3 3 3 4 4 5 5 2 1 1 2 2 3 3 4 4 5 5 3 6 6 4 7 7 6 8 8 3 1 1 2 2 Valrom 3 3...
Страница 126: ...126 4 1 1 2 2 5 1 1 2 2 3 3 6 4 4 5 5 7 6 1 1 2 2 3 3 4 4 1 4 5 5 6 6 7 1 1 2 2 3 3 4 4 5 5 A...
Страница 128: ...128 Bucure ti Bd Preciziei nr 28 sector 6 Tel 021 317 38 00 E mail office valrom ro www valrom ro...