CHRONOMITE INSTANT-TEMP WATER HEATERS 

INSTALLATION AND OPERATION INSTRUCTIONS (STANDARD MODELS) 

(Before installation, compare electrical needed for the model of heater selected)  

 

TABLE 1 

Model 

Wattage 

Voltage/AC 

Breaker 

Model 

Wattage 

Voltage/AC 

Breaker 

 

E-30 3000  110-120 

30  E-70  7000 

208 

40 

E-30 3000 

208 

15  E-70  7000  220-240 

40 

E-30 3000  220-240 

15  E-70  7000 

277 

30 

E-30 

3000 

277 15 

E-80 

8000 

208 40 

E-46 4600 

208 

30  E-80  8000  220-240 

40 

E-46 4600  220-240 

20  E-80  8000 

277 

30 

E-46 4600 

277 

20  E-90  9000  220-240 

40 

E-60 

6000 

208 30 

E-90 

9000 

277 40 

E-60 6000  220-240 

30 

 

 

 

 

E-60 6000 

277 

30 

 

 

 

 

 
Instant-Temp Specifications: 

• 

Dimensions:  

10 

3/4

 x 7 

5/16

 x 2 ¾ 

• 

Weight: 

  8 

lbs 

• 

Materials: 

 

Rugged Steel housing, plastic element 
Assembly with nichrome parts  

• 

Color: 

  White 

• 

Inlet/Outlet: 

 

Female ¼ NPT Standard Pipe Thread 

• 

Pressure 
Requirements: 

45 PSI (20-40 PSI LP Models)  
150 PSI maximum.  No pressure relief  
valve needed, unless required by local code. 

• 

Maximum Operating 
Temperature:  

140 

°

• 

Flow Switch 
Activation: 

 

Heating Coil switch activates at 1.0 GPM 

 

 

 

And deactivates at .65 GPM 

• 

Listings: 

  UL, 

IAMPO 

 

 

THE MANUFACTURER OF THIS WATER HEATER WILL NOT BE LIABLE FOR ANY DAMAGES DUE 
TO THE FAILURE TO FOLLOW THESE INSTALLATION AND OPERATION INSTRUCTIONS 

 

CAUTION:    

BEFORE BEGINNING THE INSTALLATION: 
A) 

Turn off circuit breaker to avoid dangerous electrical shocks.  

B) 

Turn off water  supply. 

 

1. 

Remove heater cover.  Attach conduit to the conduit through electrical access hole.  Then feed wires.  Do not attach 
wiring yet.   

2. 

Mount unit horizontally against the wall so label reads correctly (See Fig. 1).  Mount with four screws through the 
mounting holes located on the base plate housing using molly anchors or fasteners.  CAUTION:  Heating elements may 
burn out if unit is not mounted horizontally. 

3. 

Connect plumbing.  Use ¼ inch tapered national pipe thread at cold-water inlet and hot water outlet (See Fig. 1).  Use 
compression fittings for ease of installation and possible servicing.  Do not apply heat to these fittings. 

4. 

Run water through the unit to expel all air bubbles.  Check for leaks at all fitting joints.    

5. 

Connect wiring.  Attach ground wire to center terminal and hot wires to outer terminals  (See Fig. 3).  

6. 

Install cover.  Install the (2) cover mounting screws.   Turn on circuit breaker.  The unit is now ready for use.   

7. 

The LED indicator located on the front cover will indicate that the power is “on”.  Local plumbing and electrical codes 
must be followed in this installation of water heater and the accessories.   

8. 

Failure to comply with code requirements voids warranty.   

9. 

Optional 

(if potentiometer is to be used , install at time of installation; see page 3 for further  instructions)

:                                      

Mount potentiometer to wall using bracket supplied as shown in diagram                                    

                     a.  Connect the quick connect of the potentiometer to the connection found on the lower right side of the heater.  

Содержание E-30

Страница 1: ...ous electrical shocks B Turn off water supply 1 Remove heater cover Attach conduit to the conduit through electrical access hole Then feed wires Do not attach wiring yet 2 Mount unit horizontally against the wall so label reads correctly See Fig 1 Mount with four screws through the mounting holes located on the base plate housing using molly anchors or fasteners CAUTION Heating elements may burn o...

Страница 2: ...ox 3 3 Electrical conduit 1 conduit length as required 4 4 Dual outlet angle valve 1 female Pipe x 7 16 comp x 3 8 comp x Brass Craft PN R2701R RGH or equivalent 5 5 Compression fittings supplied 2 3 8 compression fittings x Male Pipe 6 6 Copper or flex tubing 1 3 8 OD 5 long keep short 7 7 Copper or flex tubing 1 3 8 OD length as required keep short 8 A 212 9 8 Faucet Flow Control Dual Thread 9 P...

Страница 3: ...2 Male Female 0 5 FLOW CONTROL SPECIFICATIONS FIGURE 2 Material Chrome plated brass housing FLOW CONTROL INSTALLATION Threading MODEL A212 and L212 have Male outside threads for See Parts List 8 faucets with 15 16 Female threads and 55 64 Male threads Flow controls are adaptable to other thread configurations Please call factory if an adapter is needed Potentiometer Optional Field Temperature Cont...

Страница 4: ...water pressure to heater Models require a minimum of 45 PSI Low pressure LP models require 20 45 PSI 8 Freezing Instant Temp heaters must be drained and stored if in a location subject to freezing Disconnect the inlet outlet compression fittings and blow air through one side to the heater to assist draining Failure to completely remove water from the unit will result in freezing and cracking 9 Pro...

Отзывы: