Standards applied 

(where applicable)

:

 

EUROPE

EN60598-1:

 Luminaires. General requirements and tests.

EN60598-2-1:

 Luminaires. Part 2: Particular requirements. Section one – Fixed general purpose luminaires.

EN62031:

 LED modules for general lighting. Safety specifications.

EN 62493:

 Assessment of lighting equipment related to human exposure to electromagnetic fields.

EN55015:

 Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment.

EN61547:

 Equipment for general lighting purposes. EMC immunity requirements.

EN61000-3-2:

 Electromagnetic compatibility - Limits - Limits for harmonic current emissions.

EN61000-3-3:

 Electromagnetic compatibility – Limits - Limits for Voltage Fluctuations and Flicker.

IEC EN 61000-4-2:

 Electromagnetic compatibility (EMC)- Part 4-2: Testing and measurement techniques - electrostatic discharge immunity 

test.

IEC EN 61000-4-3:

 Electromagnetic compatibility (EMC)- Part 4-3: Testing and measurement techniques - radiated, radio-frequency, 

electromagnetic field immunity test.

IEC EN 61000-4-4:

 Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst 

immunity test.

IEC EN 61000-4-5:

 Electromagnetic compatibility (EMC) - Part 4-5: Testing and measurement techniques - Surge immunity test.

IEC EN 61000-4-6:

 Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted 

disturbances, induced by radio-frequency fields.

IEC EN 61000-4-8:

 Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field 

immunity test.

IEC EN 61000-4-11:

 Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short 

interruptions and voltage variations immunity tests.

IEC 61347-2-13:

 Lamp controlgear. Particular requirements for d.c. or a.c. supplied electronic controlgear for LED modules.

IEC 61347-1:

 Lamp controlgear - Part 1: General and safety requirements.

IEC 62384:

 DC or AC supplied electronic control gear for LED modules. Performance requirements.

EN62471:

 Photobiological safety of lamps and lamp systems.

EN62560:

 Self-ballasted LED-lamps for general lighting services by voltage >50V - Safety specifications.

EN62776

: Double-capped LED lamps designed to retrofit linear fluorescent lamps - Safety specifications.

NORTH AMERICA

UL1598:

 Luminare safety.

UL8750:

 Light Emitting Diode (LED) equipment for use In lighting products.

UL2108:

 Standard for Low Voltage Lighting Systems.

UL 8800

: Standard for Horticultural Lighting Equipment

CSA C22.2 No.9.0:

 General Requirements for Luminaires.

CSA C22.2 No. 250.0:

 Luminaires

CSA C22.2 No. 250.13:

 Light Emitting Diode (LED) equipment for use in lighting products.

 

Distributor list can be found at:

www.valoya.com/contact

Valoya® is a registered trademark of Valoya Oy in the European Community, the USA and certain other countries. 

Due to our continuous program of product development, data is subject to change without notice.

19

Содержание RX Series

Страница 1: ...Version 2021 2 www valoya com 358 10 2350 300 RX Series INSTALLATION GUIDE RX500 RX600...

Страница 2: ...Personen und Sachsch den f hren SVENSKA AKTA Felaktig installation kan leda till skador p personer och lampan ESPA OL PELIGRO Una instalaci n inadecuada puede provocar lesiones o da ar la l mpara NED...

Страница 3: ...al electrical circuit protection devices is strongly advised Type C MCB s Miniature Circuit Breakers RCD Residual Current Device ICL Inrush Current Limiter SPD Surge Protection Device 13 Do not high v...

Страница 4: ...ease notify the carrier immediately and ask them to note that the delivery was not delivered in good condition If the packaging shows no damage but the goods inside are either missing defective or sho...

Страница 5: ...minaire Standard hangers x2 Optional hangers x2 ordered separately with product code ZHPF8100 Mains input mating connector with 1 9 m 6 pigtail cable field installable Dimming mating connector with 1...

Страница 6: ...Luminaire only Operational ambient temperature range C F 10 40 14 104 Distance from flammable surface mm in 300 11 8 Maximum Relative Humidity 90 non condensing Storage temperature C F 20 40 4 104 Ing...

Страница 7: ...ght incl driver mm in 176 mm 6 9 in C Height incl standard hanger mm in 303 mm 11 9 in D Length mm in 347 mm 13 6 E Width mm in 400 mm 15 7 in F Hole diameter mm in 5 mm 0 2 in F Distance between hole...

Страница 8: ...DARD HANGER 2X A 46 mm 1 8 in B 22 5 mm 0 9 in C 20 mm 0 8 in D 175 mm 6 9 in E 41 mm 1 6 in Holes 6 5 mm 0 25 in 4x OPTIONAL HANGER 2X Chain length mm in 500 mm 19 7 in CABLES A Mains cable mm in 300...

Страница 9: ...ted 9 Notes No other orientation permitted Not for intracanopy use Ensure the maximum specified operational ambient temperature around a luminaire is not exceeded by utilizing appropriate electrical o...

Страница 10: ...www valoya com 358 10 2350 300 Version 2021 2 METHOD A STANDARD HANGER METHOD B OPTIONAL HANGER Possible carabiner connection points 10 mm spanner Installation Instructions 10...

Страница 11: ...e lamp 3 If dimming is to be used connect dimming lead s black wire to the and white wire to of a compatible current sink dimmer controller 4 Connect the mains cable to the mains supply Current sink c...

Страница 12: ...cle at the specific moment power is applied Nuisance tripping issues may be improved by Reducing the quantity of LED drivers connected to a single MCB Re distributing the load over multiple mains phas...

Страница 13: ...to protect against surge peaks above 4KV e g Due to a lightning strike we recommend the installation of transient voltage surge suppression Do not apply power without the Neutral connected Ensure the...

Страница 14: ...ependent Below this the light out put is off without the need for mains switching DIMMING POSSIBILITIES BY PRODUCT RANGE BX Series BL Series L Series C Series RX Series 1 10V 0 10V 0 10V DIMMING CONTR...

Страница 15: ...MCU 1 10V Philips www lighting philips com UID8600 00 1 10V Dimmer Priva www priva com RAM www ram group com Siemens www siemens com 5TC8424 Examples of manufacturers of compatible control products sy...

Страница 16: ...tic dimming performance Luminaire LED Driver Potentiometer AC supply 1 DIM 2 DIM Live L Neutral N Earth E Luminaire LED Driver A B C D Luminaire LED Driver AC supply Live L Neutral N Earth E 1 DIM 2 D...

Страница 17: ...inaire now works then the original LED driver or mains supply to it may be at fault Note details of the problem product type quantity problem description and contact Valoya for further assistance If a...

Страница 18: ...ce number Please be prepared to provide the following information about the issue Product model information e g B200 NS1 Product serial number plus YF or XF code Quantity showing problems Detailed pro...

Страница 19: ...61000 4 6 Electromagnetic compatibility EMC Part 4 6 Testing and measurement techniques Immunity to conducted disturbances induced by radio frequency fields IEC EN 61000 4 8 Electromagnetic compatibi...

Отзывы: