Warnings

3

RoHS  PATENTS APPLY

IMPORTANT

Installation must be carried out by qualified persons, and according to the electrical safety rules & regulations 

applicable in your country!

1.  Please read this manual thoroughly before use, and retain it for future reference.
2.  Due to our continuous program of product development, data is subject to change without notice.
3.  Unauthorized product tampering invalidates warranty & is a safety risk.
4.  All electrical work must be carried out by qualified persons.
5.  Always follow appropriate electrical codes. Connection devices with appropriate ratings and voltage must 

be used.

6.  Disconnect mains power before product installation, connection, or disconnection.
7.  Products are fixed luminaires for indoor use (i.e. Install out of reach / Only movable using tools).
8.  LED-modules are non-replaceable light sources.
9.  Do not use luminaires without LED Drivers (power units) connected (BX-, C-Series).
10.  Connect LED drivers to electrical branch circuits (ensure suitable strain relief is fitted).
11.  Products with an earth connection must be earthed for safety.
12.  Installation of additional electrical circuit protection devices is strongly advised:

•  Type C MCB’s (Miniature Circuit Breakers).
•  RCD (Residual Current Device).
•  ICL (Inrush Current Limiter).
•  SPD (Surge Protection Device).

13.  Do not high voltage test.
14.  Install LED drivers against a flat surface to ensure optimal heat dissipation and lifetime (BX-, C-Series).
15.  Do not connect products installed on different mains phases to the same dimming device (dimmable 

products only).

16.  Observe published product temperature specifications and limits.
17.  Product surface temperature may become hot to the touch during use.
18.  Do not stare directly at any bright light source.
19.  As a precaution, use suitable eye protection if working for long periods under high intensity lighting.
20. Dispose of all waste in accordance with local regulations.
21.  The external flexible cable of the luminaire is only replaceable by Valoya.
22. For luminaries supplied with open-end supply cables:

a. Cables should not be concealed or extended through parts of the building structure.
b. Cables should not be located above a suspended/dropped ceiling, or permanently fixed to the building 
structure.
c. Cables must be visible over their full length, not strained, and protected from physical damage.
d. Cables must be used within their electrical ratings at the maximum temperature of the installed environment.

BEFORE YOU BEGIN

Содержание RX Series

Страница 1: ...Version 2021 2 www valoya com 358 10 2350 300 RX Series INSTALLATION GUIDE RX500 RX600...

Страница 2: ...Personen und Sachsch den f hren SVENSKA AKTA Felaktig installation kan leda till skador p personer och lampan ESPA OL PELIGRO Una instalaci n inadecuada puede provocar lesiones o da ar la l mpara NED...

Страница 3: ...al electrical circuit protection devices is strongly advised Type C MCB s Miniature Circuit Breakers RCD Residual Current Device ICL Inrush Current Limiter SPD Surge Protection Device 13 Do not high v...

Страница 4: ...ease notify the carrier immediately and ask them to note that the delivery was not delivered in good condition If the packaging shows no damage but the goods inside are either missing defective or sho...

Страница 5: ...minaire Standard hangers x2 Optional hangers x2 ordered separately with product code ZHPF8100 Mains input mating connector with 1 9 m 6 pigtail cable field installable Dimming mating connector with 1...

Страница 6: ...Luminaire only Operational ambient temperature range C F 10 40 14 104 Distance from flammable surface mm in 300 11 8 Maximum Relative Humidity 90 non condensing Storage temperature C F 20 40 4 104 Ing...

Страница 7: ...ght incl driver mm in 176 mm 6 9 in C Height incl standard hanger mm in 303 mm 11 9 in D Length mm in 347 mm 13 6 E Width mm in 400 mm 15 7 in F Hole diameter mm in 5 mm 0 2 in F Distance between hole...

Страница 8: ...DARD HANGER 2X A 46 mm 1 8 in B 22 5 mm 0 9 in C 20 mm 0 8 in D 175 mm 6 9 in E 41 mm 1 6 in Holes 6 5 mm 0 25 in 4x OPTIONAL HANGER 2X Chain length mm in 500 mm 19 7 in CABLES A Mains cable mm in 300...

Страница 9: ...ted 9 Notes No other orientation permitted Not for intracanopy use Ensure the maximum specified operational ambient temperature around a luminaire is not exceeded by utilizing appropriate electrical o...

Страница 10: ...www valoya com 358 10 2350 300 Version 2021 2 METHOD A STANDARD HANGER METHOD B OPTIONAL HANGER Possible carabiner connection points 10 mm spanner Installation Instructions 10...

Страница 11: ...e lamp 3 If dimming is to be used connect dimming lead s black wire to the and white wire to of a compatible current sink dimmer controller 4 Connect the mains cable to the mains supply Current sink c...

Страница 12: ...cle at the specific moment power is applied Nuisance tripping issues may be improved by Reducing the quantity of LED drivers connected to a single MCB Re distributing the load over multiple mains phas...

Страница 13: ...to protect against surge peaks above 4KV e g Due to a lightning strike we recommend the installation of transient voltage surge suppression Do not apply power without the Neutral connected Ensure the...

Страница 14: ...ependent Below this the light out put is off without the need for mains switching DIMMING POSSIBILITIES BY PRODUCT RANGE BX Series BL Series L Series C Series RX Series 1 10V 0 10V 0 10V DIMMING CONTR...

Страница 15: ...MCU 1 10V Philips www lighting philips com UID8600 00 1 10V Dimmer Priva www priva com RAM www ram group com Siemens www siemens com 5TC8424 Examples of manufacturers of compatible control products sy...

Страница 16: ...tic dimming performance Luminaire LED Driver Potentiometer AC supply 1 DIM 2 DIM Live L Neutral N Earth E Luminaire LED Driver A B C D Luminaire LED Driver AC supply Live L Neutral N Earth E 1 DIM 2 D...

Страница 17: ...inaire now works then the original LED driver or mains supply to it may be at fault Note details of the problem product type quantity problem description and contact Valoya for further assistance If a...

Страница 18: ...ce number Please be prepared to provide the following information about the issue Product model information e g B200 NS1 Product serial number plus YF or XF code Quantity showing problems Detailed pro...

Страница 19: ...61000 4 6 Electromagnetic compatibility EMC Part 4 6 Testing and measurement techniques Immunity to conducted disturbances induced by radio frequency fields IEC EN 61000 4 8 Electromagnetic compatibi...

Отзывы: