7
Ratings
Model
N
P
Gas
Natural
Propane
Altitude (Ft.)*
0-4,500 feet*
Input Maximum (Btu/h)
30,000
28,000
Input Minimum (Btu/h)
6,500
14,500
Manifold Pressure (in
w.c.)
3.7”
10.5”
Minimum Supply
Pressure (in w.c.)
5”
11”
Maximum Supply
Pressure (in w.c.)
10”
14”
Main Burner Injector
Marking
Cat #
82-850
Cat #
92-300
Pilot Injector Marking
#51
#30
Min. Rate By-Pass Screw
#125
#125
*High Altitude Installations
I
nput ratings are shown in BTU per hour and are
certified without deration for elevations up to 4,500 feet
(1,370 m) above sea level.
For elevations above 4,500 feet (1,370 m) in USA,
installations must be in accordance with the current
ANSI Z223.1 and/or local codes having jurisdiction.
Heating value of gas in some areas is reduced to
compensate for elevation—consult your local gas utility
to confirm.
Specifications
Approval & Codes
This appliance is certified to ANSI Z21.88-2009/
CSA 2.33-2009 American National Standard / CSA
Standard for
Vented Gas Fireplace Heaters
for use in
Canada and USA, and to CGA 2.17-91
High Altitude
Standard in Canada
. This appliance is for direct vent
installations.
This appliance complies with CSA P4.1-09
Testing
method for measuring annual fireplace efficiencies
.
The installation must conform to local codes or, in the
absence of local codes, with the
National Fuel Gas
Code, ANSI Z223.1
or the
Natural Gas and Propane
Installation Code CAN/CGA-B149
. Only qualified
licensed or trained personnel should install this
appliance.
This appliance must be electrically grounded in
accordance with local codes, or, in the absence of local
codes, with the
National Electrical Code, ANSI/NFPA
70
or the
Canadian Electrical Code, CSA C22.1
.
For installations at elevations above 4,500 feet
(1,370 m) in Canada, please consult provincial and/or
local authorities having jurisdiction.
Supply Gas
Heater engine 1300IRN is used with natural gas.
Heater engine 1300IRP is used with propane gas.
The supply pressure must be between the limits shown
in the Ratings section above.
The supply connection is 3/8” NPT male and located
on the left hand side of the firebox. A shut-off valve (not
supplied) is required on the supply line to isolate the
unit during service.
Conversion Kits
The 1300 Vogue is supplied as natural gas or propane
gas and is field convertible between fuels. See
instructions packaged with the conversion kit for further
information.
Electrical
The 1300 does not require an electrical power source
to operate as a heater. However, it requires electrical
power to operate optional 1355LHK Lighting Harness
Kit or 1270RBK Remote Blower Kit.
X
Содержание Vogue 1300IRN
Страница 40: ...40 Wiring Diagram Optional Wall Switch Kit 1265WSK Connector Red Yellow GV60 Wiring Diagram...
Страница 44: ......