Supply Gas Installation

The unit is supplied with a stainless steel flex line to 

allow the appliance to be disconnected for service. 

The flex line is supplied loose to avoid damage during 

shipping. Connect the flex to the appliance valve 

as shown below. An individual shut-off valve (not 

supplied is required on the supply line ahead of the flex 

connector.
Pressure test the supply line for leaks.
The appliance and its individual shut-off valve must be 

disconnected from the gas supply piping system during 

any pressure testing of that system at test pressures in 

excess of 1/2 psig (3.5 kPa).
The appliance must be isolated from the gas supply 

piping system by closing its individual manual shut-off 

valve during any pressure testing of the gas supply 

piping system at test pressures equal to or less than 

1/2 psig (3.5 kPa).
Failure to either disconnect or isolate the appliance 

during pressure testing may result in regulator or valve 

damages and void the warranty. Consult your dealer in 

case of damages.

Pressure Test Points

The minimum supply pressure is given in the section 

Specifications

 of this manual—page 7.

All piping and connections must be tested for leaks 

after installation or servicing. All leaks must be 

corrected immediately.
When testing for leaks:
•  Make sure that the appliance is turned off.

•  Open the manual shut-off valve.

•  Test for leaks by applying a liquid detergent or soap 

solution to all joints. Bubbles forming indicate a gas 

leak. 

Never use an open flame to check for leaks. 

Correct any leak detected immediately.

The pressure test tapping locations are shown in the 

figures above. An internal regulator within the valve 

controls the burner manifold pressure. The correct 

pressure range is shown in the table in section 

Specifications

 of this manual on page 7. The pressure 

check should be made with the burner alight and at its 

highest setting. See 

Lighting Instructions

 section for 

full operating details on page 39.

Valve Assembly

Pressure Testing

Control 

Valve

Supplied 

loose

3/8” NPT male 

connector

Manifold Test 

Pressure

Valve Inlet 

Pressure

Manifold Pressure 

Adjustment 

behind Plastic 

Cap

Содержание Vogue 1300IRN

Страница 1: ...INDUSTRIES LTD British Columbia Canada www valorfireplaces com Installation Operating Instructions Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any oth...

Страница 2: ...ble materials and finishes even though installed at listed clearances may over time discolor warp or show cracks The 1300IR requires the installation of the cement board provided with the engine Conve...

Страница 3: ...ow Removal 24 Supply Gas installation 24 Ceramic Liners Installation 26 Fuel Bed Installation 27 Ceramic Rocks Installation 28 Window Refitting 29 Remote Control Initial Set up 29 Operation Check Aera...

Страница 4: ...OBSTRUCT the flow of combustion and ventilation air Keep the front of the appliance CLEAR of all obstacles and materials for servicing and proper operation Due to the high temperature the appliance sh...

Страница 5: ...usetts Carbon Monoxide Detector Vent Terminal Signage Requirements For all side wall horizontally vented gas fueled equipment installed in every dwelling building or structure used in whole or in part...

Страница 6: ...tly mounted to the exterior of the building at a minimum height of eight 8 feet above grade directly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or...

Страница 7: ...ncies The installation must conform to local codes or in the absence of local codes with the National Fuel Gas Code ANSI Z223 1 or the Natural Gas and Propane Installation Code CAN CGA B149 Only quali...

Страница 8: ...ed wall with or without tile etc running behind the surround plate 1300IR Combustible Floor Framing See Framing Hearth Requirements Cement Board See Surround Plate requirements on page 22 for position...

Страница 9: ...1 2 26 21 1 8 21 6 3 8 7 1 2 37 1 2 to top of cement board 36 to underside of header Electrical for optional ambient light only Electrical for optional ambient light only Zero Clearance to Stand Offs...

Страница 10: ...bottom of unit for dimensions see instructions packaged with trim 0 2 4 6 8 10 12 38 36 34 32 29 26 21 1 8 Do not put furniture or objects within 36 914 mm of front of appliance Mantel Projection from...

Страница 11: ...Wall Min 6 between edge of opening and wall Face of Finished Wall Note Right Side Clearances are the same Shading denotes allowable location for combustible mantel legs Combustible Sidewall Mantel Le...

Страница 12: ...g Dimensions unit raised on wall without hearth 21 1 2 36 43 1 2 1 2 thick cement board required above and on each side of engine supplied w engine Cement board at sides is not required when using 136...

Страница 13: ...the bottom of the unit must be non combustible extending a minimum of 9 and have a 1 2 insulation board beneath supplied with 3 sided surround 1335 order insulation board separately if not using a su...

Страница 14: ...s Simpson Dura Vent DV unless otherwise specified Termination Caps 46DVA HC Standard Co axial Horizontal 46DVA VC Standard Co axial Vertical 46DVA VCH High Wind Co axial Vertical 46DVA VCE Extended Co...

Страница 15: ...lked and weatherproofed in such a manner as to Prevent rain water from entering the wall from the weather side by adequately caulking the outer vent plate to the exterior wall surface Prevent moisture...

Страница 16: ...n the direction of the exhaust flow The final pipe length when terminating through the wall may be graded downwards slightly to prevent water migration 7 A restrictor is required for all installations...

Страница 17: ...eal restrictor position may vary slightly especially when the vent pipe length is near the limits of the acceptable configurations for each type of restrictor The chart on the previous page shows the...

Страница 18: ...may be opened 12 30 C Clearance to permanently closed window recommended to prevent condensation on window 12 30 D Vertical clearance to ventilated soffit located above the terminal within a horizont...

Страница 19: ...nd offs supplied with the heater are not required for this application Rules for Co Linear Venting Maximum 40 feet vertical pipe Minimum 10 feet vertical Maximum offset 8 feet with liners at minimum 4...

Страница 20: ...l wiring for optional decorative light if used 14 Install the optional wall switch if required 15 Put the batteries in receiver and remote control handset 16 Initialize the remote control system Tools...

Страница 21: ...ms from around the appliance 4 Remove the window and set aside in a safe place to avoid damage see next page 5 Verify that you have all the components required for the installation including liners an...

Страница 22: ...PTION 2 with 1365 or 1370 Trims wide Appliance PROTRUDING from Framing Sheet metal front face of the appliance protrudes in front of the framing studs by 1 2 13 mm plus thickness of any non combustibl...

Страница 23: ...ttom front panel edge is flush with the framing Follow installation instructions supplied with 1376CSK Kit Cement board required on top on each side and on the bottom of the appliance s opening for th...

Страница 24: ...et connection is a 3 8 NPT male connector and is located on the left hand side of the firebox Use only new black iron or steel pipes or copper tubing if acceptable check local codes Note that in USA c...

Страница 25: ...warranty Consult your dealer in case of damages Pressure Test Points The minimum supply pressure is given in the section Specifications of this manual page 7 All piping and connections must be tested...

Страница 26: ...el in place 4 Place the top panel over the top edge of the rear and side panels Leave the panel to balance there until right hand side panel is installed 5 Hold the right hand side panel at an angle a...

Страница 27: ...lace the ceramic rock base inside the cast platform Make sure that it sits against the tabs behind the burner as indicated Fuel Bed Installation Ceramic base to sit against tabs behind burner The fuel...

Страница 28: ...left twig across the second and third rocks from the left rest its end on the edge of the platform as shown Make sure to leave a gap between the twig and the first rock to allow flame to come up betwe...

Страница 29: ...te control system must be initially synchronized before the first use 1 Insert alkaline batteries in the remote control receiver and handset The receiver is located left of the firebox 2 With a sharp...

Страница 30: ...ebox Air Shutter Remote Control Handset Wall Holder Installation The remote control kit for this fireplace comes complete with a wall mounted holder This holder is not required in all installations bu...

Страница 31: ...se an abrasive cleaner on the ceramic glass Any abrasion of the surface has the immediate effect of compromising the strength of the glass An emulsion type cleaner is recommended Use a soft damp cloth...

Страница 32: ...119mm Light Bulb Replacement if installed The appliance may be equipped with a decorative light inside the firebox located in front of the window To replace the light bulb follow these steps 1 Turn o...

Страница 33: ...Replace the 4 AA batteries 5 Replace the cover 6 Put the receiver back on its plate If it was unhooked replace the antenna in its clip IMPORTANT The antenna MUST NOT TOUCH the ignition wire to avoid a...

Страница 34: ...the 1265WSK Wall Switch Kit Thermostatic Remote Control Wall Switch optional Manual On Off Switch Manual On Off Switch In cases where you want to turn off your fireplace and cannot do it with the rem...

Страница 35: ...turns automatically to maximum flame height 1 Make sure that the MAN knob on the valve is in ON position 2 Make sure that the switch on the valve is in the I position 3 Press and hold the OFF and lar...

Страница 36: ...ressing either the or buttons Mode Sun Moon TEMP Daytime temperature setting Nighttime temperature setting TIMER Start time setting Stop time setting Flame Height The flame height can be adjusted in t...

Страница 37: ...ore you get up P1 start time and to turn off when you leave for the day P1 stop time Then you can set your fireplace to turn on again at the end of the day P2 start time and to turn off when you go to...

Страница 38: ...rying safety products for children Remote Control Operation Automatic Standby Mode If there is no transmission from the handset to the receiver within a 6 hour period the appliance will go to Standby...

Страница 39: ...ear the oor If you smell gas STOP Follow B in the safety information above on this label If you don t smell gas go to the next step 3 AUTOMATIC IGNITION g 1 Locate the pilot g 3 inside of rebox at Lef...

Страница 40: ...40 Wiring Diagram Optional Wall Switch Kit 1265WSK Connector Red Yellow GV60 Wiring Diagram...

Страница 41: ...n for air from other household equipment or appliances iii Damage due to chemicals dampness condensation or sulphur in the fuel supply lines which exceeds industry standards i This warranty does not c...

Страница 42: ...sembly 4001279X 24 Location Support Assembly 2 4001850 25 Top Gasket 4001269 26 Bottom Gasket 4001363 27 Sealing Gasket 4001364 28 Side Gasket 2 4001268 29 Valve 4000873 30 Cable Interruptor 4001035 3...

Страница 43: ...8 9 10 53 59 36 11a 11b Pilot Assy 12a to 18 19a 19b 22a 22b 24 Module Plate Gaskets 25 to 28 33 29 34 NG LPG 21a 21b 20a 20b 54 55 57 56 58 39 40 41 42 43 44 38 37 45 46 30 31 32 32a 49 50 51 52 47 4...

Страница 44: ......

Страница 45: ...l 1300IR NG natural gas LPG propane Serial No Front Trim code description e g 1370GSB Glass Surround Purchase date mm dd yyyy Home Owner Name Address City Province State Postal Code Zip Phone Email Ad...

Страница 46: ...Product Postage needed Were you given all documentation and manuals for your product YES NO Miles Industries Ltd 190 2255 Dollarton Highway North Vancouver BC V7H 3B1 Canada Fold here Online Warranty...

Отзывы: