2.3.1

Conventional fireplace and hearth
The appliance can be installed to a fireplace
complete with surround and hearth.

The fireplace opening must be within the following dimensions:

Width:

Max.

457mm

Min:

305mm

Height

Max:

610mm*

Min.

510mm

* Though the total height of the closure plate
will accommodate a maximum opening
height of 650mm, heights above 610mm
will leave the closure plate and sealing tape
visible above the appliance. 

The appliance must be mounted on a non-combustible hearth
(N.B. conglomerate marble hearths are considered as non-
combustible). The hearth must be at least 880mm wide x 300mm
deep. The hearth material must be at least 12mm thick. The
periphery of the hearth (or fender) should be at least 50mm above
floor level to discourage the placing of carpets or rugs over it.

The appliance can be fitted to a purpose
made proprietary class “O” - 100“C or O”-
150°C surround.

2.3.2.

Wall mounted
The appliance can be wall mounted.
The appliance is not suitable for installation
on combustible walls.
The opening must be within the following
dimensions:
Width:

Max. 356mm
Min.

305mm

Height:

Max. 610mm*
Min.

376mm

* Though the total height of the closure plate
will accommodate a maximum opening
height of 650mm, heights above 610mm
will leave the closure plate and sealing tape
visible above the appliance. 
The bottom of the fire must be at least
102mm above the finished floor
covering. This requires that the top of the
opening must be at least 612mm above the
finished floor covering.

2.3.3.

Precast flue 
The appliance can be installed to a fireplace
that has a precast concrete or clay flue block
system conforming to BS1289. The
appliance is suitable for installations
conforming to older versions of BS1289 as
well as the current edition. The flue blocks
must have a minimum width not less than

63mm and a cross-sectional area not less
than 13,000mm

2

. Older editions of BS1289

required a cross-sectional area of
13,000mm

2

. The current revision of the

standard requires 16,500mm

2

. This

appliance is suitable in both cases.
The chimney should be one or two storeys
high but not less than 3m
vertical height and be correctly terminated.
No mortar fangs between the blocks should
be extruded into the flueway. If raking blocks
are used, they must be fitted in accordance
with the manufacturer’s instructions. Mortar
must not be allowed to drop down and
accumulate in the raked positions.
The fireplace opening must be within the
following dimensions:
Width:

Max. 457mm
Min:

305mm

Height

Max: 610mm*
Min.

610mm*

2.3.4.

Metal flue box
The appliance can be installed to a metal flue
box complying with the
constructional requirements of the current
edition of BS715.
The opening must be within the following
dimensions:
Width:

Max. 457mm

Min:

380mm

Height

Max: 610mm*

Min.

510mm

*Though the total height of the closure plate
will accommodate a maximum opening
height of 650mm, heights above 610mm
will leave the closure plate and sealing tape
visible above the appliance.

2.4.

Flues
Suitable flues are:
a) 225mm x 225mm conventional brick
flue. If a liner is used, it must be a minimum
of 127mm (5in.) diameter. The liner must be
sealed to the surrounding area above the
fireplace opening and to the top of the
chimney and have an approved terminal.
b) A properly constructed precast flue
conforming to BS1289 (See
section.2.2.3.)

Page 5

INSTALLATION & SERVICING INSTRUCTIONS

Valor Folium Format U/down 12/4  5/22/00  9:33 AM  Page 5

Содержание regency 328

Страница 1: ...IRELAND IE ONLY We trust that these instructions give sufficient details to enable this appliance to be installed and maintained satisfactorily However if further information is required our Valor adv...

Страница 2: ...ndards of safety quality and performance Careful Installation Valor is a Corgi registered company All our gas fires must be installed by a competent Corgi Registered Installer in accordance with our I...

Страница 3: ...ting the radiants 9 Full operating checks 9 Control setting check 9 Fitting bottom panel trims 10 Spillage check 10 Fitting dress guard 11 Final review 11 Servicing parts replacement 11 Replacing radi...

Страница 4: ...ers to work to recognised standards In the United Kingdom the installation must also be in accordance with A These instructions B All the relevant parts of local regulations C The current edition of t...

Страница 5: ...system conforming to BS1289 The appliance is suitable for installations conforming to older versions of BS1289 as well as the current edition The flue blocks must have a minimum width not less than 63...

Страница 6: ...bottom of the flue spigot See figure 2 2 7 The front face of the fireplace should be reasonably flat to ensure that a good seal can be made with the closure plate 2 8 The minimum clearance from the to...

Страница 7: ...ting to install it is worth checking that the piezo electric spark ignition system operates satisfactorily To initiate the spark depress the control knob and while keeping it depressed turn to the 1 I...

Страница 8: ...ther floor covering To achieve this the bottom of the closure plate must also be at least 102mm above the finished floor covering The centre of the flue spigot hole will be at least 486mm above the fi...

Страница 9: ...safety and servicing 4 3 3 The supply pipe must be of a rigid material e g copper A flexible connection must not be made 4 3 4 Pressure check the installation pipework for gas soundness in accordance...

Страница 10: ...nd tighten their securing screws 5 3 SPILLAGE CHECK A spillage check must be made before leaving the installed appliance with the customer 5 3 1 Close all doors and windows in the room containing the...

Страница 11: ...the radiants 6 6 Advise that any cleaning must only be carried out when the fire is off and cold 6 7 Mention that the radiants may become brown with use that this is quite normal and has no adverse e...

Страница 12: ...cage is cleaned before refitting Make sure that it locates squarely onto the pilot unit without any gaps between the cage edges and the pilot unit 7 4 TO REMOVE THE BURNER GAS TAP PILOT ASSEMBLY 7 4...

Страница 13: ...ing the split pin 7 8 TO REMOVE THE COMPLETE FIRE TO CHECK CHIMNEY FOR DEBRIS 7 8 1 To gain access see section 7 2 7 8 2 Remove the radiants and store in a safe place 7 8 3 Remove the floor plate 7 8...

Страница 14: ...levels of personal safety and performance efficiency it is essential that the opening at the back of the fire and the flue are kept clear of any form of obstruction It is possible that deposits of mo...

Страница 15: ...leaned with a damp cloth and dried with a soft duster Obstinate marks can be removed from the guard and trims using soapy water Never use abrasive cleaners The radiants can be cleaned with a soft brus...

Страница 16: ...pilot The pilot flame can be seen through the opening immediately below the centre radiant Figure 2 If the pilot does not light turn the control knob to OFF and try again In the unlikely event of fai...

Страница 17: ...will automatically shut off the supply of gas to the fire if for any reason the pilot goes out If this device does operate or if the fire is turned off accidentally or intentionally always wait three...

Страница 18: ...IN THE UNITED KINGDOM GB AND THE REPUBLIC OF IRELAND IE ONLY We trust that these instructions give sufficient details to enable this appliance to be installed and maintained satisfactorily However if...

Страница 19: ...ndards of safety quality and performance Careful Installation Valor is a Corgi registered company All our gas fires must be installed by a competent Corgi Registered Installer in accordance with our I...

Страница 20: ...you care for your Valor gas fire Please read thoroughly before using and keep for future reference We trust that these instructions give sufficient details to enable this appliance to be operated and...

Отзывы: