recheck for spillage as above. If an extractor
fan is installed in the same room as the
appliance or a connecting room, check that
spillage does not occur with the fan
operating and all doors and other openings
between the fan and the appliance open. If
the smoke is drawn into the appliance,
continue with the installation. If the test is
not satisfactory, Disconnect the appliance
and advise the customer of the cause of
failure.
5.4.
FIT THE DRESS GUARD
Locate the bottom of the dress guard in the
two holes in the bottom panel apron. Engage
the two spring projections at the top of the
guard in the slots under the front decorative
canopy.
6.1.
Recheck the operation of the control.
6.2.
Visually inspect the appliance. Clean off any
marks incurred during
installation.
6.3.
Advise the customer how to operate the
appliance.
6.4.
Advise the user that the appliance can be lit
with a match if necessary by inserting it
through the central opening at the bottom of
the radiant box.
6.5.
Advise that the dressguard can be removed
to replace the radiants.
6.6.
Advise that any cleaning must only be
carried out when the fire is off and cold.
6.7.
Mention that the radiants may become
brown with use, that this is quite
normal and has no adverse effect.
6.8.
Recommend that the appliance should be
serviced and the chimney inspected by a
competent person (In the UK a CORGI
registered person) at least annually.
If the appliance is in premises in the United
Kingdom occupied by a
tenant, point out that by law a landlord
must have any gas appliance, flue and
pipework which is situated in a tenant’s
premises checked for safety at least every
12 months.
6.9.
Hand these instructions and the user’s
instructions to the customer.
Always turn off the gas supply and make sure that
the appliance is cool before commencing any
servicing.
Always test for gas soundness and spillage after
servicing the appliance.
It is recommended that, at least once a year, the
appliance is disconnected and the catchment space
behind the closure plate checked and cleared of
any debris. The closure plate must be resealed to
the wall after checking.
Page 11
INSTALLATION & SERVICING INSTRUCTIONS
figure 9
6.FINAL REVIEW
7.SERVICING & PARTS
REPLACEMENT
Valor Folium Format U/down 12/4 5/22/00 9:33 AM Page 11