27
48”
20”
44”
48”
20”
34-1/2” between
underside of
non-combustible
board and base
of heater
1/2” thick non-combustible
board required above engine
(not supplied). See page .
Any surface directly in front of
the unit which is at a height of
less than 4” from the bottom of
the unit must be non-combustible.
May be reduced
by thickness of
additional
non-combustible
wall finish applied
on top of 1/2”
non-combustible
board when using
trims other than
the 1430FFK Fixed
Framing Kit
NOTE: This unit requires a
solid platform to support it.
Combustible framing allowed
beneath fireplace. Please note
that any shims used
underneath to raise the
heater should be set back
1/2” behind front face of
framing otherwise top face
of shims may be visible.
Between underside of header and
base of heater. Base of heater must
be at finished hearth height. However,
please note that the 1440 4-sided
trim extends 1-1/2” below the base
of heater
. Increase cavity height
accordingly.
Framing Requirements
30
Insulation Board Under Hearth
Appliance
Combustible
Flooring
1/2” Insulation board,
36” wide x 12” deep
Non-combustible hearth with
1/2” combustible shim below
Note: If using
optional LDK
HeatShift Duct
Kit, refer to LDK
instructions packed
with kits as framing
is aff ected.