17
1400 Driftwood Kit—Correct Flame Picture
1400 Decorative Glass Murano—Correct Flame Picture
1400 Decorative Glass Set—Correct Flame Picture
1400 Traditional Log Set—Correct Flame Picture
Pilot Flame can be seen at
the back of the fi re bed
Pilot Flame can be seen at
the back of the fi re bed
Pilot Flame can be seen
under the right rear logs
Pilot Flame
Thermocouple
Probe must be in
Flame
Pilot Flame can be seen
under the rear log
Checking Pilot & Burner Flames
A periodic check of the pilot and burner fl ames should
be made. Check after the fi re has been on for at least
30 minutes. The pilot fl ame must cover the tip of the
thermocouple probe. The main burner fl ame pattern will
vary from appliance to appliance depending on the type
of installation and climatic conditions.
The appliance area must always be kept clear and
free from combustible materials, gasoline and other
fl ammable vapors and liquids.
Inspect the vent terminal outdoors regularly to make
sure that snow, trees, bushes, leaves, or other objects
do not obstruct it.
Examine the vent system and terminal regularly. We
recommend annually.
Servicing & Maintenance