Programmable Remote Control

Setting the 

fl

 ame

Use this setting when you want a particular 

fl

 ame level. For instance, you 

want to watch 

fl

 ames burn at their highest level and you don’t mind if the 

room is too hot.

To raise the 

fl

 ame, press and hold the 

 button until the flame gets to the 

desired level. Let go.
To lower the 

fl

 ame, press and hold the 

 button until the 

fl

 ame gets to the 

desired level. Let go.

The 

fl

 ame level

 will remain just as you set it.

Automatic ON/OFF

You can set your 

fi

 replace to come on before you wake up and turn off after 

you leave and then, turn on again just before you come home and turn off 
after going to bed.
You can leave it like this for the heating season.

Decide what temperature you want your 

fi

 replace to be at. Also, decide 

what time you want your 

fi

 replace to turn on and off. Finally, decide what 

time you want it to come back on and off in the afternoon or evening. For 
the 

fi

 rst few times you set the timer, it’s handy to write these times down.

Set the temperature (just as you did in the section 

Setting the 

temperature.)

Press the 

TIMER

 button and hold it until 

P1 

 appears and flashes. Let 

go. 

While 

fl

 ashing, push the buttons 

 (hour) and 

 (minutes) to set the 

time at which you want your 

fi

 replace to turn on in the morning.

Press the 

TIMER

 button and hold it until 

P1 

 appears and 

fl

 ashes. Let 

go. While 

fl

 ashing, push the buttons 

 (hour) and 

 (minutes) to set the 

time at which you want your 

fi

 replace to turn off when you leave.

Press the 

TIMER

 

button and hold it until 

P2 

 

appears and 

fl

 ashes. Let 

go. While 

fl

 ashing, push the buttons 

 (hour) and 

 (minutes) to set the 

time at which you want your 

fi

 replace will turn on again in the afternoon.

Press the 

TIMER

 button and hold it until 

P2 

 

appears and 

fl

 ashes. Let 

go. While 

fl

 ashing, push the buttons 

 (hour) and 

 (minutes) to set the 

time at which you want your 

fi

 replace to turn off in the evening.

Note: If you want to set your 

fi

 replace for only one time on and off, set 

P2 

 

and 

P2 

☽ 

for the same times as 

P1 

The remote will record the 

P1 

☽ 

off 

time for both 

P2 

times.

To temporarily override the timer setting, just press 

AUTO

 or 

 and 

 to go 

back to manual settings. Press 

TIMER

 to go back to your settings.

When your remote control displays 

BATT

, you need to replace the battery 

with a new 9 volt alkaline battery—6LR61/MN1604.

1.

2.

1.

2.

3.

4.

5.

6.

f i r e - p a r t s . c o m

Содержание 739DVN

Страница 1: ...ge personal injury or loss of life Installation and service must be performed by a qualified installer service agency or the gas supplier WARNING This product must be installed by a licensed plumber o...

Страница 2: ...hecks 23 Operational Warnings 24 Lighting Instructions 25 Maintenance 26 Programmable Remote Control 28 Venting Options 30 Warranty 31 The information contained in this installation manual is believed...

Страница 3: ...t 744FVI Optional Outer Trims 3 sided Contour Trim Kit Kit 746 3 sided Deluxe Trim Kit Kit 747 4 sided Contour Trim Kit Kit 748 4 sided Deluxe Trim Kit Kit 749 Additional Optional Features Circulating...

Страница 4: ...nces Appliance Dimensions See Page 9 for clearance information 28 3 8 R 1 12 19 1 2 2 5 8 36 1 2 26 5 8 9 1 4 Gas Line 7 3 8 Electrical 20 12 5 8 with Contour Outer Trim 12 with Deluxe Outer Trim 10 w...

Страница 5: ...ice technician to inspect the heater and to replace any part of the control system and any gas control which has been under water The appliance area must be kept free from combustible materials gasoli...

Страница 6: ...t when doing any heavy lifting 2 3 Vent Safety Venting must be installed according to local codes and good venting practices 2 4 Electrical Code These appliances when installed must be electrically gr...

Страница 7: ...urpose of input adjustment 10 5 in w c 2 6 kPa 14 0 in w c 3 5 kPa Orifice size Bray CAT 82 650 Bray CAT 92 260 Maximum input rating 24 000 BTU hr 24 000 BTU hr High altitude US 0 2 000 ft 0 610 m US...

Страница 8: ...d components necessary to complete the installation Check that the gas and electrical supplies are ready Prepare opening clean chase level base etc Install vent Install base unit and connect vent Inst...

Страница 9: ...incial state or local codes The section 6 2 shows the minimum install dimensions for the model 739 Note The model 739 is certified without requiring a hearth projection although local codes may requir...

Страница 10: ...Materials Combustible materials Material such as wood compressed paper plant fibers plastics or any material capable of igniting and burning whether flame proofed or not plastered or un plastered Non...

Страница 11: ...rt Maximum vertical height 30 ft measured to bottom of termination Minimum vertical height 10 ft measured to bottom of termination Maximum horizontal run 4 ft measured center to center of pipe Maximum...

Страница 12: ...vent pipe from the outlet of the appliance to termination allow for any offsets in the chase and sufficient vertical height above the roof Apply RTV sealant to the appliance s vent pipe and slide ove...

Страница 13: ...ntains 3 pieces 1 Remote control kit handset receiver and wires 4 1 5 V AA batteries 1 9 V battery 2 Side shroud mounting brackets 1 Top shroud mounting bracket 1 Gas inlet pipe connection adapter 1 R...

Страница 14: ...14 Pack Contents Rear Log Rest Remote Control Ceramic Log Set 742CFB Cast Iron Front 741SFB Standard Metal Front Ceramic Brick Pack 739DVN or 739DVP Engine Engine Pack fire parts com...

Страница 15: ...through the IGN position to PILOT A spark should flash across from the pilot electrode to the pilot burner shield as shown below Appliance Preparation Do not remove the window when the appliance is h...

Страница 16: ...he board is in line with the tab on the wiring harness plug Connect the wires A with the L terminals to the connectors B on the control valve Please note that the connectors are different sizes the sm...

Страница 17: ...at the left side of the control unit Supply line connection to the inlet pipe is 3 8 NPT If the circulating fan is to be installed be aware that the supply pipe run inside the case should be at the s...

Страница 18: ...e lower ledge and be flat against the rear of the firebox Slide the Left Ceramic Panel against the left side of the firebox and up to the Rear Ceramic Panel The Panel will have to be angled to fit ins...

Страница 19: ...re 13 4 Place the Left Side Center Log in position locating the thick part on the left side of the Ash Bed on the 2 pins provided with its nose resting on top of the Ash Bed center projection See figu...

Страница 20: ...ion Rear Log Rest See no 2 on p 18 Rear Log Pins Left Center Log Pins Front Support Ash Bed Rear Log Front Log Left Center Twig Right Center Twig Cross Twig 13 3 13 4 13 5 13 6 13 7 13 8 13 9 13 2 13...

Страница 21: ...14 1 above for window refitting 1 2 3 4 1 2 3 Window Refitting 15 1 Burner Pilot Checks Check ignition pilot stability burner flames and the full range of the thermostat settings using the rotary swit...

Страница 22: ...The brackets will mount flush to the bottom inside corner of each side section Attach the complete trim unit to the firebox with four screws as shown in figure 16 1c 16 2 741SFB Standard Metal Front S...

Страница 23: ...ssociated with the varying sulfur content of the gas You may have the problem for a time and then not see it for many months when it will reappear in your area We have discussed this problem with cera...

Страница 24: ...echnician to inspect the appliance and replace any part of the gas control system which has been under water DO NOT use this appliance if you smell gas WHAT TO DO IF YOU SMELL GAS OPEN WINDOWS DO NOT...

Страница 25: ...flame adjustment knob as far clockwise as possible 3 Turn the gas control knob clockwise to OFF NOTE The knob cannot be turned from PILOT to OFF unless it is pushed in partially Do not force 4 Wait f...

Страница 26: ...Lift up and unhook the upper casting and lower casting If you have difficulties removing either front please refer to section 16 Remove the bottom center spring loaded bolt Turn the 5 remaining spring...

Страница 27: ...trees or other object do not obstruct it Examine the whole vent system regularly using a qualified agency We recommend an annual inspection 20 5 General Servicing If your appliance requires any servic...

Страница 28: ...button sets the hour the button sets the minutes Set the time Note You must start setting the time while the F is flashing If it stops flashing go back to 1 The display shows C 24 hour or F 12 hour To...

Страница 29: ...re Press the TIMER button and hold it until P1 appears and flashes Let go While flashing push the buttons hour and minutes to set the time at which you want your fireplace to turn on in the morning Pr...

Страница 30: ...AL ADAPTER 923GK ALUMINUM FLEXIBLE LINER 3 DIAMETER 2280 Series 3 ACFL NOTE 2 ply liner approved to CAN ULC S635 suitable for venting gas appliances As manufactured by Z Flex Notes 1 Simpson Dura Vent...

Страница 31: ...sehold equipment or appliances iii Damage due to chemicals dampness condensation or sulphur in the fuel supply lines which exceeds industry standards This warranty does not cover glass log breakage or...

Отзывы: