
27
Maintenance
20.4 Checks
A periodic check of the pilot and burner
fl
ames should be made. Check after the
fi
re has been on for at
least 30 minutes. The pilot
fl
ame must cover the tip of the thermocouple probe. The main burner
fl
ame
pattern will vary from appliance to appliance depending on the type of installation and climatic conditions.
The appliance area must always be kept clear and free from combustible materials, gasoline and other
fl
ammable vapors and liquids.
Inspect the vent terminal outdoors regularly to make sure that dirt, snow, insects, leaves and trees or
other object do not obstruct it.
Examine the whole vent system regularly using a quali
fi
ed agency. We recommend an annual inspection.
20.5 General Servicing
If your appliance requires any servicing, contact your supplier quoting the model number. It will be helpful if
the appliance’s serial number can also be quoted. The serial number is on the rating plate, which is located
under the
fi
rebox, and is accessible by opening the bottom access panel of the front.
The repair parts are shown in the separate repair parts lea
fl
et. Please always quote the part number and
description when requesting a spare part.
1.
2.
3.
4.
Pilot
fl
ame
Flame picture
Performance of LPG appliances may be affected by the quality of commercial
gas supplied in your area.
f i r e - p a r t s . c o m