background image

OWNER’S GUIDE

Page 16

M A I N T E N A N C E

Battery replacement

This appliance requires one 9V PP3 Ever Ready Silver Seal (or equivalent) battery.

To replace the battery remove the bottom front cover casting.
Fit the new battery firmly to the
connections on the ignition block (See
figure 18).

Regular maintenance

In order to achieve and maintain high
levels of personal safety and performance
efficiency, it is essential that the opening
at the back of the fire and the flue are kept
clear of any form of obstruction. It is
possible that deposits of mortar or soot
could fall and accumulate causing the flue
to be blocked or restricted and so
preventing proper clearance of dangerous
exhaust fumes.
In the United Kingdom it is the law that a landlord must have any gas appliance, flue
and pipework which is situated in a tenant’s premises checked for safety at least every
twelve months by a competent person (In the U.K, a CORGI registered installer).
We recommend that all gas appliances and their flues, wherever situated, are checked
annually.

Figure 18. Battery Fitting

Содержание 641

Страница 1: ...ing and keep for future reference We trust that this guide gives sufficient details to enable your appliance to be operated and maintained satisfactorily However if further information is required our...

Страница 2: ...st Standards Valor is a member of the Society of British Gas Industries which works to ensure high standards of safety quality and performance Careful Installation Valor is a CORGI registered company...

Страница 3: ...Ceramic burner 10 FUEL BED REFITTING 11 MAINTENANCE 16 Battery replacement 16 Regular maintenance 16 Servicing 17 This gas fire is designed to meet the most stringent quality performance and safety r...

Страница 4: ...ed Kingdom installation must be in accordance with the latest edition of the Gas Safety installation use Regulations In the Republic of Ireland installation must be in accordance with all national and...

Страница 5: ...ut the suitability of any wall covering near your fire Soft wall coverings e g embossed vinyl etc which have a raised pattern are easily affected by heat They may therefore scorch or become discoloure...

Страница 6: ...3 4kW Gross Has a minimum natural gas input of 2 7kW Gross Has a minimum natural gas output of 1 06kW Gross Model 641 when converted using kit number 0591301 Has a maximum propane gas input of 6 7kW...

Страница 7: ...hich senses that the heat from the pilot flame is correct If this probe is cool the device will prevent any gas flow unless the control knob is held in at the ignition position If for any reason the f...

Страница 8: ...e When first turned on the flames will appear predominantly blue The coals will take time to warm up Although some glow will be seen after approximately ten minutes the full visual effect will only be...

Страница 9: ...ing with a taper See figure 3 In the unlikely event of failure of the ignition spark the pilot can be lit by a taper or long spill Insert the taper or spill alongside of the left side wall of the fire...

Страница 10: ...t is important to take care when handling these articles to ensure that the release of dust is kept to a minimum Light coatings of soot will usually be burnt off during the normal operation of the fir...

Страница 11: ...figure 4 Installer Note that the small round holes in the burner plaques that will be covered by the base coal are not gas burner ports They are simply a consequence of the plaque manufacturing proce...

Страница 12: ...at 90 to the rear of the firebox 7 Hold coal A upright with the arrow pointing to the top Locate coal A as shown in figure 6 8 Locate coals B to E so that they are firmly seated in the valleys in the...

Страница 13: ...old coal E upright with the arrow pointing to the top Locate coal E as shown in figure 10 13 Hold coal F upright with the arrow pointing to the top Locate coal F as shown in figure 11 14 This will com...

Страница 14: ...the arrow pointing to the top Locate coal G as shown in figure 12 17 Hold coal H upright with the arrow pointing to the top Locate coal H as shown in figure 13 18 Hold coal I upright with the arrow p...

Страница 15: ...J as shown in figure 15 20 Hold coal K upright with the arrow pointing to the top Locate coal K as shown in figure 16 21 Hold coal L upright with the arrow pointing to the top Locate coal L as shown i...

Страница 16: ...ng at the back of the fire and the flue are kept clear of any form of obstruction It is possible that deposits of mortar or soot could fall and accumulate causing the flue to be blocked or restricted...

Страница 17: ...and colour c Model Name d Serial Number To be found on a swing plate located below the burner and behind the bottom front cover e The fault problem or request If you wish to replace any of the owner r...

Страница 18: ...re VALOR TECHNICAL HELPLINE 08706 061 065 To report faults or arrange for your fire to be serviced VALOR SERVICE 08706 090 081 For sales or product information VALOR SALES 08706 061 067 To order spare...

Отзывы: