1.

 

SAFETY INFORMATION 

WARNING: Do not operate the appliance with the 
glass front removed, cracked or broken. Replacement 
of the glass should be done by a licensed or qualified 
service person. 
(The whole window unit may be temporarily removed 
by the owner for cleaning the interior of the firebox, 
etc.)  
Only the authorized Valor replacement window unit 
listed in the repair parts booklet must be fitted - never 
use substitutes. 
If the glass is damaged, search inside and adjacent to 
the appliance for any glass fragments. 
 
Due to high temperatures, the appliance should be 
located out of traffic and away from furniture and 
draperies. 
 
Children and adults should be alerted to the hazards 
of high surface temperatures and should stay away to 
avoid burns or clothing ignition. 
 
Young children should be carefully supervised when 
they are in the same room as the appliance. 
 
Clothing or other flammable material should not be 
placed on or near the appliance. 
 
This appliance must be installed and repaired by a 
qualified service person. The appliance should be 
inspected before use and at least annually by a 
professional service person. More frequent cleaning 
may be required due to excessive lint from carpeting, 
bedding material, etc. It is imperative that control 
compartments, burners and circulating air 
passageways of the appliance are kept clean. 
 

Keep curtains, clothing, furniture and other 
flammable materials a safe distance from all parts of 
the appliance and its vent system. 
 
Keep the appliance area well clear and free from 
combustible materials, gasoline and other flammable 
vapors and liquids. 
 
Never attempt to burn paper or any other material in 
the appliance. 
 
The venting terminal must not be recessed into a wall 
or siding. 
 
The vent terminal on the outside wall must be kept 
free from obstructions. No objects should be placed 
within 2 feet (60cm) of the vent terminal. The terminal 
is hot during operation and requires a guard if it is 
accessible to any person. An approved Valor guard is 
available from your dealer. 
 
During extreme weather conditions ensure that the 
vent outlet is free from ice and snow before attempting 
to light. 
 
Do not use this appliance if any part has been under 
water. Immediately call a qualified service technician 
to inspect the appliance and to replace any part of the 
control system and any gas control which has been 
under water. 

 

NOTE 

When operating your new fireplace for the first time, some vapors may be released due to the burning of curing compounds 
used in the manufacture of the appliance. They may cause a slight odor and could cause the flames to be the full height of the 
fire box, or even slightly higher, for the first few hours of operation. It is also possible that these vapors could set off any 
smoke detection alarms in the immediate vicinity. These vapors are quite normal on new appliances and are totally harmless 
but you may wish to open windows into the room to reduce the vapor/odor build up. After a few hours use the vapors will 
have disappeared and the flames will be at their normal height.   
During the first hour of use, the ceramic firebox walls may go a smoky color. This is not soot. It is a temporary effect lasting 
only while the ceramic material becomes stabilized. The walls will revert to their initial color after your fire has been used for 
one or two hours.     

Содержание 534AN

Страница 1: ...nt Installation and service must be performed by a qualified installer service agency or the gas supplier This appliance may be installed in an aftermarket permanently located manufactured mobile home...

Страница 2: ...13 4 15 Top Vent Connection Offset and Through the Roof Termination 13 4 16 Vent Location 14 5 SUPPLY GAS 15 6 PACK CONTENTS 15 7 APPLIANCE PREPARATION 17 7 1 Window Removal 17 7 2 Ignition Spark Chec...

Страница 3: ...r flammable vapors and liquids Never attempt to burn paper or any other material in the appliance The venting terminal must not be recessed into a wall or siding The vent terminal on the outside wall...

Страница 4: ...ion in areas where natural gas was not available at the time of initial installation 2 4 Venting options 2 4 1 Direct vent installations One or more of the accessories listed below must be used for ea...

Страница 5: ...clearance B 7 178mm 8 203mm 9 229mm 10 254mm 11 279mm 12 305mm 14 356mm Figure 1 Major dimensions clearances without optional trims Shown with 601SFB Front 3 sided trims 4 sided trims Figure 2 601SFB...

Страница 6: ...These appliances when installed must be electrically grounded in accordance with local codes or in the absence of local codes with the National Electrical Code ANSI NFPA 70 or the Canadian Electrical...

Страница 7: ...K only The horizontal vent run can not be extended by the use of any vent accessory pipes 4 3 Rear Vent Connection Flat on Wall with Snorkel Termination See figure 6 For use on horizontal installation...

Страница 8: ...tical pipe run and at sides of horizontal pipe run 2 5 1cm For installations with a horizontal rear termination the combination of horizontal and vertical vent pipes must be within the allowed area sh...

Страница 9: ...on See figure 10 Adapter 817VAK one 90 vent elbow 990B Dura vent pipe lengths a vertical vent terminal and roof flashing will be required Various other ceiling or roof items may be necessary depending...

Страница 10: ...ng on the particular installation See venting options section of this manual Note 1 The distance from the roof to the lowest terminal discharge opening depends on the roof pitch and must be in accorda...

Страница 11: ...izontal pipe run inside building Outside wall shields thimbles 1 12 7cm G Clearance to combustible materials below horizontal pipe run 15 16 3 3cm H Clearance to combustible materials all round vertic...

Страница 12: ...sional requirements in sections 4 10 and 4 11 apply Adapter 817VAK one 90 vent elbow 990B a Dura vent snorkel termination and Dura vent pipe lengths will be required 942 Dura vent thimble kit may also...

Страница 13: ...vent elbows 945B wall straps a vertical vent terminal roof flashing and Dura vent pipe lengths will be required Various other ceiling or roof items may be necessary depending on the particular install...

Страница 14: ...ensation on window 12 30 D Vertical clearance to ventilated soffit located above the terminal within a horizontal distance of 2 feet 60 cm from the center line of the terminal 18 46 E Clearance to unv...

Страница 15: ...to studding 601SFB Standard metal front Alternative 1 Upper louver unit 1 Lower louver unit 2 Side channels 2 Hinge studs 2 Hinge spacers 2 Magnet counterplates 602CFB Cast iron front Alternative 1 T...

Страница 16: ...16 Figure 19 Pack contents...

Страница 17: ...clockwise through the IGN position to PILOT A spark should flash across from the pilot electrode to the pilot burner shield See figure 21 7 3 Flame Control Motor Check See figure 22 Fit the battery ho...

Страница 18: ...collars to check alignment Tighten the 12 screws to secure the outer collar 6 Fit the cover plate and seal Removed from the rear to the top vent opening with 12 screws 7 5 817VAK Pipe Adapter Fitting...

Страница 19: ...es by refitting the two screws at the top rear corners and by two screws from the pack fitted near the front 6 Bend the two top rear stand offs and fit to the heat shield with three screws each see fi...

Страница 20: ...opening set at Less than 3ft 91cm A Maximum Top From 3ft 91cm to 6ft 183cm A Minimum Less than 3ft 6 107cm A Maximum Horizontal through wall Rear From 3ft 6 107cm to 6ft 183cm A Minimum Less than 20f...

Страница 21: ...ing through two holes each side with the woodscrews supplied The top support angle should abut the wall finish but is not fixed to the framing 3 Check the wall finish requirements with the homeowner I...

Страница 22: ...position e Cut the vent tubes squarely to length f Make sure that all Styrofoam is removed from the vent unit after cutting 2 Free the appliance from the frame studding by removing the four screws ins...

Страница 23: ...tube will pass clearly through the plate with the wall shield at the top Place the inner wall plate over the terminal unit 3 Slide the appliance terminal into the wall Make sure that the drain hole i...

Страница 24: ...through the roof If directly above the position where it penetrates the ceiling drop a plumb from the roof to the small hole in the ceiling and mark the roof at this spot If rafters or other obstructi...

Страница 25: ...ase through the opening at the bottom right side of the heater case 2 Cut off the L terminals from the switch wires on the remote control receiver and remove insulation from approximately at ends of w...

Страница 26: ...the gas supply piping system by closing its individual manual shut off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than psig 3 5kPa f Failure...

Страница 27: ...behind the burner See figure 50 2 Place the rear log in position locating the two top projections in the ash bed into the holes in the rear log See figure 51 3 Place the two front logs at the front of...

Страница 28: ...nce and all other controls wall switch remote hand unit See owner s lighting instructions further on in this manual for full details Aeration adjustment As described in section 11 for natural gas appl...

Страница 29: ...nit using the hinge studs and hinge spacers as shown in figure 59 2 Fix the two adhesive backed magnet counterplates to the tabs at the firebox sides which line up with the magnets on the lower louver...

Отзывы: