![Valor Fires 954 Скачать руководство пользователя страница 53](http://html1.mh-extra.com/html/valor-fires/954/954_installer-and-owner-manual_3263538053.webp)
Do
always use a fireguard complying with BS 8423 for the protection of young
children, the elderly, the infirm or pet animals.
Do
wait three minutes before attempting to relight if the fire is switched off or the
flames are extinguished for any reason (Your fire is fitted with a safety device that will
automatically shut off the gas supply to the fire, if for any reason, the flame goes out)
Do
get advice about the suitability of any wall covering near your fire. Soft wall
coverings (e.g. embossed vinyl, etc.) which have a raised pattern are easily affected
by heat. They may, therefore, scorch or become discoloured when close to a heating
appliance. Please bear this in mind whenever you are considering redecorating.
Do
provide a minimum side clearance as detailed in figure 2. Please bear this in mind
if ever you are altering the room.
Don’t
hang clothing, towels or any other fabrics over the fire.
Don’t
add any extra fuel effect pieces above the number stated in the installer and
owner guide supplied with the ceramic fuel effect. The installer may have attached it
to this guide or placed it inside. Adding extra fuel effect pieces could cause a safety
hazard and consequent health hazards.
Don’t
put paper or other materials onto your fire.
Don’t
use the fire with damaged base ceramics.
Don’t
place any combustible material (rugs, carpet, plastic tiles, etc.) on the hearth
Don’t
attempt to clean or service the fire until it has been switched off and allowed to
cool completely.
GAS CONSUMPTION
Model 954
Has a maximum natural gas input of 6.0kW (Gross)
Has a maximum natural gas output of 3.1kW
Has a minimum natural gas input of 2.7kW (Gross)
Has a minimum natural gas output of 1.4kW
Model 954 when converted using kit number 0595221
Has a maximum propane gas input of 6.1kW (Gross)
Has a maximum propane gas output of 3.3kW
Has a minimum propane gas input of 4.3kW (Gross)
Has a minimum propane gas output of 2.3kW
Page 53
©
Baxi Heating U.K. Limited 2010.
OWNER GUIDE
Содержание 954
Страница 15: ...Page 15 Baxi Heating U K Limited 2010 INSTALLER GUIDE Figure 4 Hearth and fireplace opening dimensions...
Страница 20: ...Page 20 Baxi Heating U K Limited 2010 INSTALLER GUIDE Figure 7 Pack contents...
Страница 21: ...Page 21 Baxi Heating U K Limited 2010 INSTALLER GUIDE Figure 7 Pack contents continued...
Страница 22: ...Page 22 Baxi Heating U K Limited 2010 INSTALLER GUIDE Figure 7 Pack contents continued...
Страница 64: ...Baxi Heating U K Limited 2010...