16.4 To remove the fascia.
16.4.1 All models except Brooklyn and Moonlight.
1.
Remove the bottom front cover or fire
front casting.
2.
Detach the control-linking bar from the
control pivot bracket by removing the knurled
screw, which joins the control linking bar to
the control pivot unit (See figure 41).
3.
Remove the two screws securing the
bottom of the fascia to the sides of the
hotbox (See figure 42).
4.
Make sure that the control linking bar
has been detached (See point 2)
.
Carefully
lift the fascia unit upward to clear the upper
retaining brackets on the hotbox (See figure
43). Pull the fascia clear and place carefully
aside.
5.
Refit in the reverse order. Make sure that
the fascia is properly located over the upper
retaining brackets. See section 11 of this manual for
detailed fitting instructions.
16.4.2 To remove the fascia on Brooklyn and
Moonlight models.
1.
The bottom of the fascia is held in place with
magnets. Hold the lower outside edges of the fascia
and gently pull forward. With the bottom released,
lift the fascia upward and clear of the upper hanging
brackets on the hotbox.
Page 44
©
Baxi Heating U.K. Limited 2010.
INSTALLER GUIDE
Figure 43. Fascia removal
(Shown with ‘Chic’ fascia)
Figure 42. Securing screws
(fascia may differ from that
shown)
Figure 41. Control linkage
disconnection (Burner detail may
differ from that shown)
Содержание 954
Страница 15: ...Page 15 Baxi Heating U K Limited 2010 INSTALLER GUIDE Figure 4 Hearth and fireplace opening dimensions...
Страница 20: ...Page 20 Baxi Heating U K Limited 2010 INSTALLER GUIDE Figure 7 Pack contents...
Страница 21: ...Page 21 Baxi Heating U K Limited 2010 INSTALLER GUIDE Figure 7 Pack contents continued...
Страница 22: ...Page 22 Baxi Heating U K Limited 2010 INSTALLER GUIDE Figure 7 Pack contents continued...
Страница 64: ...Baxi Heating U K Limited 2010...