7. REMOVING THE FASCIA AND FIREFRONT
To gain access to the boiler for servicing and maintenance it will be necessary to
remove the firefront. Do this as below:
1.
Unscrew the ash pan knob and remove the Hearth casting from beneath the fascia.
2.
Firmly hold the lower sides of the firefront fascia and gently pull the bottom forward
to release the magnets that hold the
bottom in place. Lift the fascia upward
and forward until the fascia hanging
brackets are clear of the upper
hanging brackets on the firefront.
Place the fascia away from the work
area.
3.
The firefront is held in place with a
single wire. It will be necessary to
loosen and remove the wire at one
side. Do this by placing a flat ended
screw driver or similar tool behind the
wire loop on the front of the firefront
(See figure 14). Push the wire loop
towards the outer hole and pull on the
wire where it passes through an outer
hole in the firefront. The wire should
become loose and can then be pulled from the outer hole. With the end of the wire
free, gently pull the firefront forward.
4.
After completing work on the boiler fit the firefront and fascia as in section 6
of this guide.
Page 17
INSTALLER GUIDE
©
Baxi Heating U.K. Limited 2010.
Figure 14. To loosen the wire