background image

5131426/01

Model 823

Electric Heater

Fitted with one of the following fascia: 

Liberty

or

Vermont.

(GC No. EF-032-29)

This guide is intended to help you
install and care for your Valor Fires
electric heater.  Please read carefully
before installing and using your
heater. However, if further information
is required, our

Valor Fires Technical Helpline

will be pleased to help.
Telephone 

0844 8711 565 

(National

call rates apply in the United
Kingdom)
In the Republic of Ireland
Telephone

0044 844 8711 565

Important: Please keep your guide in a safe place for future reference

INSTALLER AND OWNER GUIDE

© 

Baxi Heating U.K. Limited 2008.

Содержание 823

Страница 1: ...ead carefully before installing and using your heater However if further information is required our Valor Fires Technical Helpline will be pleased to help Telephone 0844 8711 565 National call rates...

Страница 2: ...ission to reproduce any part of this publication should be made giving details of the proposed use to the following address The Company Secretary Baxi Heating UK Limited The Wyvern Business Park Stani...

Страница 3: ...y requirements to provide our customers with many years of trouble free service This guide aims to improve your understanding and appreciation of your new heater by providing simple and informative in...

Страница 4: ...ps of fingers for support Always keep the heater as close to the body as possible This will minimise the cantilever action Use gloves to provide additional grip Always use assistance if required 2 SAF...

Страница 5: ...an electrical socket the socket must always be accessible in order to disconnect the heater from the electrical supply for maintenance and cleaning Important This heater must be earthed The heater is...

Страница 6: ...e heater is not suitable for this type of installation The minimum mounting height from the finished floor level to the underside of the fascia is 125mm See figure 4 for details Q Can the heater be in...

Страница 7: ...e Contents Qty Illustrations are not to scale Contents Qty Illustrations are not to scale Heater 1 Cover plate 1 Rear Spacer frame 1 Wall mounting bracket 2 Front Spacer frame 1 Bag of coals Lower sec...

Страница 8: ...the cable guide 1 Before removing the cable guide please note that the wider part of the cable guide is on the outer edge of the base See figure 3 Item 1 2 To remove the cable guide push and lift the...

Страница 9: ...3 Item 1 1 Gently pinch the sides of the cable guide See figure 3 Item 4 and push the cable guide into the required rectangular slot 2 Place the electrical cable into the guide and close the top of th...

Страница 10: ...s a wooden frame behind it then use all four fixing holes in the bracket This is required to spread the load If the wall plugs supplied are not satisfactory purpose made plasterboard fixings can be pu...

Страница 11: ...ear of the heater side flanges 2 The rear spacer has raised dimples These should be at the rear of the heater and not against the heater flange Locate the spacer frame as in point 2 figure 5 and secur...

Страница 12: ...cure the cover plate to the base of the heater using two No 8 x 3 8 screws supplied See figure 8 Hanging the heater 1 Hang the heater body on the wall hanging bracket Ensure that the heater is central...

Страница 13: ...lace using the two M5 x 10mm screws supplied Fit these through the holes in the base of the fascia Fitting the fuel effect 1 Place the loose coals on top of the fuel support It is not necessary to use...

Страница 14: ...Control Use Point the handset in the direction of the heater The Maximum operating distance is 3 metres Press the red On Off button to initiate the handset a red lamp on the heater will illuminate Se...

Страница 15: ...one side of the heater This is possibly a light bulb failure Remove the light bulb s as follows and check it them in a table lamp that is known to work If it they do not work in the table lamp then re...

Страница 16: ...a problem that is different to those in the previous examples 1 3 Please call the Valor Fires Technical Helpline Telephone 0844 8711 565 National call rates apply in the United Kingdom In the Republic...

Страница 17: ...he heater Read section 5 of this guide Cleaning and maintaining the heater If the problem cannot be resolved simply call our service division heateam on 08706 090 081 to book an engineer visit or for...

Страница 18: ...any third party repair or replacement costs that we haven t been told about or agreed with you in advance Compensation or consequential losses e g loss of earnings business losses stress and inconveni...

Страница 19: ...M Y Y Date of Installation Fascia name Block Capitals Fascia code Can be found close to the information label Block Capitals Model 8 2 3 Serial number Can be found on the information label See figure...

Страница 20: ...Baxi Heating U K Limited 2008...