10

© VALLOX • We reserve the right to make changes without prior notice.

What the units include can vary depending on the sales area.

Vallox

121

SE

TECHNICAL DATA

Internal electrical connection Vallox 121 SE 

(code A3560)

S   Supply air fan 
E   Extract air fan 
M1   Autotransformer with 

protective voltage coil 
230VAC/16VAC 

L   Earthed cord 
HK   Maintenance switch
T1   Heating radiator safety 

thermostat 130 °C (reset, 
switch the unit off)

T2   Overheat protection 90 °C 

(automatic reset)

R2   Post-heating radiator
M   Damper motor 24 VAC

Wire colours 
s   = blue 
m   = black 
r   = brown 
va   = white 
vi   = green 
p   = red 
h   = grey 
kv   = yellow-green

16 V

0 V

0 V

230 V

7023500

2011-11-17 JK

M1

GND

-+

A

B

PWM1

PWM2

S RH2

S RH1

L

N

NO

NC

90°C

130°C

R2

L

N L

r

N N L L1 L2 L3

N1 L4

NC

GND

PWM

 1

s

s

r

r

s

s

kv

kv

p

p

k

k

HK

0-10V DC 

A B - + M S + S +

+

1 2

S S -

%RH1

%RH2

12x0.25mm²

3184600

PWM

 2

r

s

s

kv

kv

r

r h

h

5

10

3

1

NO

L

R

r

s

T1

T2

1

2

3

M

S PRESSURE SWITCH

S REMOTE MONITORING

S FIREPLACE SWITCH

S FAULT SIGNAL

S FAULT SIGNAL

Extract air

Outdoor air to the unit

Supply air to the dwelling

Exhaust air

Supply air from cell

blue/red switch

RS-485 BUS

connection box (on top of the unit)

FAULT SIGNAL

FIREPLACE SWITCH

FAN CONTROL

FUSE

MOLEX CONNECTOR

S

E

Содержание VALLOX 121 SE L

Страница 1: ...de A3560 Models VALLOX 121 SE R VALLOX 121 SE L Electrical connection 230 V 50 Hz 5 7 A Degree of protection provided by enclosures IP 34 Fans direct current Extract air 0 117 kW 0 9 A 106 dm3 s 100 P...

Страница 2: ...ing to the highest measuring result 1 5 carbon dioxide sensors can be connected as options to the VALLOX 121 SE unit The adjustment is switched on off and if needed the setpoint 500 2000 ppm is set at...

Страница 3: ...ples of such situations are high humidity loads such as a swimming pool or a situation where the exhaust air duct has frozen through Remember Switch post heating off when it starts to get too warm in...

Страница 4: ...u To settings menu see manual In order to move to the Settings menu press the and buttons simultaneous ly In the Settings menu you can chan ge setpoints for the ventilation unit 2 3 Week clock control...

Страница 5: ...tory settings can be restored by pressing the and buttons simultaneously Remember to ensure that the setpoints are in accordance with the factory settings for this unit 3 16 Choosing cascade adjustmen...

Страница 6: ...n speed 2 Sp 2 supply air temperature 17 C Temp 17 Move the cursor to the following hour Monday D 1 16 00 H 16 fan speed 4 Sp 4 supply air temperature 20 C Temp 20 Move the cursor to the following hou...

Страница 7: ...by pulling carefully Place a thin sheet board or paper under the fan in order to prevent the bottom tank from being scratched when removing the fan Unfasten the fixing screw of the fan H hex socket he...

Страница 8: ...es at speed 1 check the fan speed Wiring fault in the carbon dioxide sensor in the control panel or in the humidity sensor or the cable is of the wrong type Contact a maintenance company The connectio...

Страница 9: ...ed operating range Volume flow rate Sound power level in supply air duct one duct by octave band LW dB Sound power level in extract air duct one duct by octave band LW dB ADJUSTMENT POSITION AIR FLOW...

Страница 10: ...R2 Post heating radiator M Damper motor 24 VAC Wire colours s blue m black r brown va white vi green p red h grey kv yellow green 16 V 0 V 0 V 230 V 7023500 2011 11 17 JK M1 GND A B PWM1 PWM2 S RH2 S...

Страница 11: ...ke sure that its address is 1 If control panels have the same address they go to bus fault state In this case remove one of the control panels and change the address of the other panel The above menti...

Страница 12: ...water connections The delivery includes a Silent Kick water seal By connecting a pipe to the water seal the water condensing from extract air can be led to a floor drain not directly to the drain Sil...

Отзывы: